Loading...
B22-1365 - 31191 VIA DEL VERDEFINALED10/02/25 875047 GRANT MAURY CONSTRUCTION INC 1443 N EL CAMINO REAL, STE A SAN CLEMENTE, CA 92672 949 410-0469 Letter of Transmittal 3707 W Garden Grove Blvd. Suite 100, Orange, CA 92868 phone 714.568.1010 fax 714.568.1028 www.csgengr.com ORA – BPR - 160801 To: City of San Juan Capistrano Date Completed: 11/14/2022 Review #: 2 32400 Paseo Adelanto Date Received: 11/8/2022 San Juan Capistrano, CA 92675 CSG #: 4215082 Attn: Building & Safety Division Agency Plan Check #: B22-1365 Job Address: 31191 Via Del Verde Job Description: DINING AREA AC & FAN - 700 SF Status: X Plan is approved. Plan is approved with conditions. See remarks. Plan is approved with redlines. See remarks. Plan is approved with redlines and conditions. See remarks. Plan requires corrections. See attached list. We have reviewed the following documents ( Digital only): 2 Plans Truss Calculations 2 Structural Calculations Energy Calculations Soil Report Specifications Geotechnical Review Letter Special Inspection Form(s) Other: Special items to note: X Plan has been stamped and signed by CSG Environmental Health Services approval required X Special inspection required for Epoxy anchors Hardship Form included Remarks: From: 1st Khanh Nguyen, P.E. 2nd Matthew Corrigan CSG Consultants Inc. 31191 Via Del Verde Kristi Bullock 3West Environmental, Inc.Page 1 of 6 3 WEST ENVIRON MEN TAL, IN C. 949-482-1357 info@3westenviro.com https://www.3westenviro.com LIMITE D ASBESTOS SAMPLING REPORT 31191 V i a Del V erde San Juan Capi s trano, CA 92675 Kri sti Bul lock OCTOBER 19, 2023 In spector Ti mothy Maskew CAC, CM I , CDP H -I /A 949-482-1357 info@ 3west env iro .co m 31191 Via Del Verde Kristi Bullock 3West Environmental, Inc.Page 2 of 6 TAB LE OF CONTENTS 1: Backgr ound 2: Bulk Sampling 3: Limitatio ns and Attachments 3 4 6 31191 Via Del Verde Kristi Bullock 3West Environmental, Inc.Page 3 of 6 Background 3West Env ironmental, I nc. was ret ained by Krist i Bullock t o conduct L imited Asbest o s Sampling at 31191 V ia Del Verde,San Juan Capist rano, CA 92675 due t o suspect ACM being impact ed in t he pro cess of planned renov atio n activ it y . The site v isit occurred on 10/19/2023 by t he inspector shown below. Structure Hou se Obvious Structural or Fire Damage N one Observed Year Built 1997 Square Footage 2689 Levels 2 Foundation Sl ab-on -grade Inspector Certications: CAC - Timothy Maskew This inspection and report wer e performed by Timothy Maskew of 3West Environmental, Inc.  Timothy A Maskew 949-482-1357 205 Avenida Del Mar #210 San Clemente, C A 92674 Lab Accreditation: NVLAP: EMLAB P&K - Tustin, CA NVLAP Lab Code: 200757-0 2841 Dow Avenue, Suite 300  Tustin, CA 92780 Dan Shelby   Phone: 623-298-1015  Email: dan.shelby @euronset.com 1: B ACKGR OUND Informati on section-NTM3ZGYwZGItNmEwMC00M 2N lLTk3MjItZWNkN 2M3N z VkZmU0 31191 Via Del Verde Kristi Bullock 3West Environmental, Inc.Page 4 of 6 No Asbestos Detected As a result of t he Limit ed Asbestos Sam pling conduct ed, it was found that Asbestos: W as n ot  dete c t e d on the materials/areas listed below and att ached o o r plan. The sample lo cat ions list ed are a represent at iv e sampling of t he mat erials in t he structure. # Of Samples Collected 21 Bul k Samp les Areas/Materials: No Asbestos Detected Sampl e ID Mat erial Loca tion Cond/ Fria bl e Asbestos Cont e nt Approx Qty 1 A,B,C Drywall w/Joint Compound Wa lls Cei ling G/F None De tected 900 SF 2 A,B,C T il e w/Thinset Fl ooring Ma st e r Bathroom G/N F None De tected 90 SF 3 A,B,C T il e w/Thinset Fl ooring J&J Bat hroom G/N F None De tected 90 SF 4 A,B,C T il e w/Thinset Fl ooring E nt ry/Bar/Oce G/N F None De tected 200 SF 5 A,B,C Stucco E xt erior G/N F None De tected 900 SF 6 A,B,C T il e w/Ceme nt Fl ooring E xt erior G/N F None De tected 900 SF 7 A,B,C T il e w/Thinset Wa ll Fami ly/Living Room G/N F None De tected 150 SF General Contractor Asbestos Co ntaining M at erials were not present in t he m at erials sampled in the areas listed. 2: BULK SAMPLING Informati on section-MzI2MDI5M2EtZj BmYy00MzQ3LTg5YzMtYTFj OGFhMj g zZGRh 31191 Via Del Verde Kristi Bullock 3West Environmental, Inc.Page 5 of 6 A G eneral Contractor is ab le to work on thes e areas /materials tes ted as it relates to no as b es tos b eing d etected . An as b es tos ab atement contractor is not need ed on these areas/materials. H o wev er, if ot her suspect Asbest o s Cont aining M aterials (ACM ) will be disturbed t hen t hese need to be t est ed prior t obeing dist urbed o r renov ated. Testing Protocol: Bulk Sampling Protocol & Analysis Bulk sampling was in accordance with the AHERA inspection protocol as listed in 40 CFR 763.86. Samples were analyzed via the EPA recommended method of Polarized Light Microscopy (PLM) in accordance with EPA Test Method 600/R-93/116. Bulk Samples were analyzed in accordance with the AHERA protocol as listed in 40 CFR 763.87. Testing Protocol: Bulk Limits ACM ACCM Non-ACCM None Detected  >1%  <1% via PLM  <1% via Point Count  >0.1% via Point Count ≤0.1% v ia Point Count  ND  Because of the limit ations of PLM analy sis, if the Bulk Samples analyzed v ia PLM are found to cont ain <1% asbest os then this is considered ACM. In order to be classied as ACCM these samples would need to be analyzed via "1,000 Point Count" and v eried to cont ain <1% asbest os.  Materials t hat t est positive at >1% asbest os are regulated by the EPA, Cal/OSHA, SCAQMD (Rule 1403) or SDAPCD (Rule 1206) and other regulatory agencies. Materials with results at <1% asbest os via PLM are also regulated unless v eried to cont ain <0.1% asbest os via 1,000 Point Count according to the EPA Applicabilit y Determination Index Control Number C112. 31191 Via Del Verde Kristi Bullock 3West Environmental, Inc.Page 6 of 6 Specic A reas This asbest o s sampling was limited to the areas and materials list ed abo v e. I f o ther suspect Asbestos Co ntaining M at erials (ACM ) will be dist urbed then these need t o be tested prio r to being disturbed or reno v at ed. Bulk Sampling Limitations 3West Environmental, Inc. provided limited asbestos sampling of agreed upon areas and materials. Some materials may be hidden, which are not included in this sampling. Further assessment of suspect Asbestos Containing Material (ACM) may be accomplished by a more compr ehensiv e sur v ey. The samples collected for testing ar e believed to be representative of the area(s) evaluated. However, if additional suspect Asbestos Containing Materials are found during renovation or remediation activities, these materials should be sampled by qualied per sonnel, and analyzed for content prior to further disturbance. Quantities of ACM are approximate. These number s should be conrmed prior to r emoval, r epair, or remediation activities.  No warr anty , expressed or implied, is made regar ding the professional opinions pr esented in this report. Var iations in site conditions may exist and conditions not observed or descr ibed in this r eport may be encounter ed during subsequent activities.  Our conclusions, recommendations, and opinions ar e based on an analysis of the obser v ed site conditions. It should be understood that the conditions of a site can change with time as a result of natural processes or the activities of man at the subject site or nearby sites. In addition, changes to the applicable laws, regulations, codes, and standards of practice may occur due to gover nment action or the broadening of knowledge. The ndings of this report may , therefore, be invalidated ov er time, in part or in whole, unless evaluated again. Attachments Lab Resul ts, Chai n of Cu stody, Fl oor Pl an , NVLAP 3: LIMITATIONS AND ATTACHMENTS Informati on section-OTA5ZmYwYmQtZGEzOS00Mj k2LWFkNGYtZTFmYWIzMGMz Yz Uz Approved by: Approved Signatory Danny Li Report for: Tim Maskew, Certified Asbestos Consultant 3West Environmental, Inc. 205 Avenida Del Mar #210 San Clemente, CA 92674 Regarding: Eurofins EPK Built Environment Testing, LLC Project: 33603-Asbestos; 31191 Via Del Verde, San Juan Capistrano, CA EML ID: 3427147 All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested. Eurofins EPK Built Environment Testing, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor. Dates of Analysis: Asbestos PLM: 10-25-2023 Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267) NVLAP Lab Code 200757-0 EMLab ID: 3427147, Page 1 of 7Eurofins EPK Built Environment Testing, LLC Eurofins EPK Built Environment Testing, LLC 2841 Dow Avenue, Suite 300, Tustin, CA 92780 (800) 651-4802 www.eurofinsus.com/BuiltClient: 3West Environmental, Inc. C/O: Tim Maskew, Certified Asbestos Consultant Re: 33603-Asbestos; 31191 Via Del Verde, San Juan Capistrano, CA Date of Sampling: 10-19-2023 Date of Receipt: 10-20-2023 Date of Report: 10-25-2023 ASBESTOS PLM REPORT Total Samples Submitted:21 Total Samples Analyzed:21 Total Samples with Layer Asbestos Content > 1%:0 Location: 1A, Drywall with Joint Compound, Walls/Ceiling Lab ID-Version‡: 16683583-1 Sample Layers Asbestos Content White Joint Compound ND White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate Location: 1B, Drywall with Joint Compound, Walls/Ceiling Lab ID-Version‡: 16683584-1 Sample Layers Asbestos Content White Joint Compound 1 ND Cream Paint ND White Joint Compound 2 ND White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Poor Location: 1C, Drywall with Joint Compound, Walls/Ceiling Lab ID-Version‡: 16683585-1 Sample Layers Asbestos Content White Joint Compound ND White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate Location: 2A, Tile with Thinset, Flooring - Master Bathroom Lab ID-Version‡: 16683586-1 Sample Layers Asbestos Content Gray Tile ND White Thinset ND Beige Semi-Fibrous Material ND Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Poor EMLab ID: 3427147, Page 2 of 7Eurofins EPK Built Environment Testing, LLC The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC 2841 Dow Avenue, Suite 300, Tustin, CA 92780 (800) 651-4802 www.eurofinsus.com/BuiltClient: 3West Environmental, Inc. C/O: Tim Maskew, Certified Asbestos Consultant Re: 33603-Asbestos; 31191 Via Del Verde, San Juan Capistrano, CA Date of Sampling: 10-19-2023 Date of Receipt: 10-20-2023 Date of Report: 10-25-2023 ASBESTOS PLM REPORT Location: 2B, Tile with Thinset, Flooring - Master Bathroom Lab ID-Version‡: 16683587-1 Sample Layers Asbestos Content Gray Tile ND White Thinset ND Beige Semi-Fibrous Material ND Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Poor EMLab ID: 3427147, Page 3 of 7Eurofins EPK Built Environment Testing, LLC The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC 2841 Dow Avenue, Suite 300, Tustin, CA 92780 (800) 651-4802 www.eurofinsus.com/BuiltClient: 3West Environmental, Inc. C/O: Tim Maskew, Certified Asbestos Consultant Re: 33603-Asbestos; 31191 Via Del Verde, San Juan Capistrano, CA Date of Sampling: 10-19-2023 Date of Receipt: 10-20-2023 Date of Report: 10-25-2023 ASBESTOS PLM REPORT Location: 2C, Tile with Thinset, Flooring - Master Bathroom Lab ID-Version‡: 16683588-1 Sample Layers Asbestos Content Gray Tile ND White Thinset ND Beige Semi-Fibrous Material ND Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Poor Location: 3A, Tile with Thinset, J & J Bath Lab ID-Version‡: 16683589-1 Sample Layers Asbestos Content White Tile ND Gray Thinset ND Sample Composite Homogeneity: Moderate Location: 3B, Tile with Thinset, J & J Bath Lab ID-Version‡: 16683590-1 Sample Layers Asbestos Content White Tile ND Gray Thinset ND Sample Composite Homogeneity: Moderate Location: 3C, Tile with Thinset, J & J Bath Lab ID-Version‡: 16683591-1 Sample Layers Asbestos Content White Tile ND Gray Thinset ND Sample Composite Homogeneity: Moderate EMLab ID: 3427147, Page 4 of 7Eurofins EPK Built Environment Testing, LLC The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC 2841 Dow Avenue, Suite 300, Tustin, CA 92780 (800) 651-4802 www.eurofinsus.com/BuiltClient: 3West Environmental, Inc. C/O: Tim Maskew, Certified Asbestos Consultant Re: 33603-Asbestos; 31191 Via Del Verde, San Juan Capistrano, CA Date of Sampling: 10-19-2023 Date of Receipt: 10-20-2023 Date of Report: 10-25-2023 ASBESTOS PLM REPORT Location: 4A, Tile with Thinset, Flooring - Entry/Bar/Office Lab ID-Version‡: 16683592-1 Sample Layers Asbestos Content Tan Tile ND Gray Thinset ND Sample Composite Homogeneity: Moderate Location: 4B, Tile with Thinset, Flooring - Entry/Bar/Office Lab ID-Version‡: 16683593-1 Sample Layers Asbestos Content Tan Tile ND Gray Thinset ND Sample Composite Homogeneity: Moderate Location: 4C, Tile with Thinset, Flooring - Entry/Bar/Office Lab ID-Version‡: 16683594-1 Sample Layers Asbestos Content Tan Tile ND Gray Thinset ND Sample Composite Homogeneity: Moderate Location: 5A, Stucco, - Ext.Lab ID-Version‡: 16683595-1 Sample Layers Asbestos Content White Stucco ND Gray Stucco ND Sample Composite Homogeneity: Moderate EMLab ID: 3427147, Page 5 of 7Eurofins EPK Built Environment Testing, LLC The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC 2841 Dow Avenue, Suite 300, Tustin, CA 92780 (800) 651-4802 www.eurofinsus.com/BuiltClient: 3West Environmental, Inc. C/O: Tim Maskew, Certified Asbestos Consultant Re: 33603-Asbestos; 31191 Via Del Verde, San Juan Capistrano, CA Date of Sampling: 10-19-2023 Date of Receipt: 10-20-2023 Date of Report: 10-25-2023 ASBESTOS PLM REPORT Location: 5B, Stucco, - Ext.Lab ID-Version‡: 16683596-1 Sample Layers Asbestos Content White Stucco ND Gray Stucco ND Sample Composite Homogeneity: Moderate Location: 5C, Stucco, - Ext.Lab ID-Version‡: 16683597-1 Sample Layers Asbestos Content White Stucco ND Gray Stucco ND Sample Composite Homogeneity: Moderate Location: 6A, Tile with Cement, Ext. - Flooring Lab ID-Version‡: 16683598-1 Sample Layers Asbestos Content Gray Tile ND Gray Concrete (Cement)ND Blue Cementitious Material ND Sample Composite Homogeneity: Poor Location: 6B, Tile with Cement, Ext. - Flooring Lab ID-Version‡: 16683599-1 Sample Layers Asbestos Content Gray Tile ND Gray Concrete (Cement)ND Blue Cementitious Material ND Sample Composite Homogeneity: Poor EMLab ID: 3427147, Page 6 of 7Eurofins EPK Built Environment Testing, LLC The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC 2841 Dow Avenue, Suite 300, Tustin, CA 92780 (800) 651-4802 www.eurofinsus.com/BuiltClient: 3West Environmental, Inc. C/O: Tim Maskew, Certified Asbestos Consultant Re: 33603-Asbestos; 31191 Via Del Verde, San Juan Capistrano, CA Date of Sampling: 10-19-2023 Date of Receipt: 10-20-2023 Date of Report: 10-25-2023 ASBESTOS PLM REPORT Location: 6C, Tile with Cement, Ext. - Flooring Lab ID-Version‡: 16683600-1 Sample Layers Asbestos Content Gray Tile ND Gray Concrete (Cement)ND Blue Cementitious Material ND Beige Cementitious Material ND Sample Composite Homogeneity: Poor Location: 7A, Tile with Thinset, Living Room Wall Lab ID-Version‡: 16683601-1 Sample Layers Asbestos Content Gray Tile ND White Thinset ND Sample Composite Homogeneity: Moderate Location: 7B, Tile with Thinset, Living Room Wall Lab ID-Version‡: 16683602-1 Sample Layers Asbestos Content Gray Tile ND White Thinset ND Sample Composite Homogeneity: Moderate Location: 7C, Tile with Thinset, Living Room Wall Lab ID-Version‡: 16683603-1 Sample Layers Asbestos Content Gray Tile ND White Thinset ND Sample Composite Homogeneity: Moderate EMLab ID: 3427147, Page 7 of 7Eurofins EPK Built Environment Testing, LLC The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". United States Department of Commerce National Institute of Standards and TechnologyCertificate of Accreditation to ISO/IEC 17025:2017NVLAP LAB CODE: 200757-0Eurofins EMLab P&KTustin, CAis accredited by the National Voluntary Laboratory Accreditation Program for specific services, listed on the Scope of Accreditation, for:Asbestos Fiber Analysis2023-01-01 through 2023-12-31Effective DatesFor the National Voluntary Laboratory Accreditation ProgramThis laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communique dated January 2009). SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 Page 1 of 1 For the National Voluntary Laboratory Accreditation Program Effective National Voluntary Laboratory Accreditation Program 2023-01-01 through 2023-12-31 Eurofins EMLab P&K 2841 Dow Avenue, Suite 300 Tustin, CA 92780 Dan Shelby Phone: 623-298-1015 Email: dan.shelby@et.eurofinsus.com http://www.emlabpk.com ASBESTOS FIBER ANALYSIS NVLAP LAB CODE 200757-0 Bulk Asbestos Analysis Code Description 18/A01 EPA -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples 18/A03 EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials Airborne Asbestos Analysis Code Description 18/A02 U.S. EPA's "Interim Transmission Electron Microscopy Analytical Methods-Mandatory and Nonmandatory-and Mandatory Section to Determine Completion of Response Actions" as found in 40 CFR, Part 763, Subpart E, Appendix A.