B24-0696 - 31242 PASEO OLIVOSFINAL09/17/2025 9 11 200a mpu Additional Address Info: PROCEDURE FOR INSTALLATION 1. PHONE DIG ALERT "811" AT LEAST TWO DAYS PRIOR TO TRENCHING FOR LOCATION OF UNDERGROUND UTILITIES. 2. Phone Service Coordinator at 949-361-8066 for the following: - 3 Working days prior to trenching to arrange pre-meet with inspector and initiate trenching process. - After excavation of trench, installation of conduit and service entrance equipment at meter location, CALL FOR INSPECTION. Do not cover conduit without inspector's written approval to backfill. - When trench is backfilled and compacted, CALL FOR INSPECTION. - If service entrance equipment is installed after backfill, CALL FOR INSPECTION OF THE EQUIPMENT. 3. Meter cannot be set until inspector has approved installation, including service equipment, and receipt of city/county/state inspection Metering: Self-Contained Meter Clips: 4 Utilities Maximum Contribution to Fault Current: 10000Phase: 1# of Wires: 3 Voltage: 120/240 Bend Info: 3" 90 DEG 36"R DB60Bend Type: HANDHOLE Riser Quad: Stop Trench: from PoleLadder Arms: Standards Page: Handhole Lid Shall Read: Structure #: SH729839Station ID #: 196-214 Temp Service Charge Due $ 0.00 Assessor's Parcel Number: Additional Information: To minimize the electrical outage, you are advised to schedule a morning disconnect with an afternoon reconnect. There is no charge for this service. Before you change out your meter consider (1) SDG&E needs notice to schedule a crew and (2) SDG&E will not reconnect the service without municipal approval on the new panel. Please contact the City of San Juan Capistrano regarding permits and inspections. City of San Juan Capistrano inspection should be received prior to 2:00 p.m. on the same day as the disconnection of service to allow the SDG&E crew enough time for reconnection of the service on the same day. Number/Size of Main Switch: 1@200Service Panel Rating: 200 Conduit Size: 3"Conduit Installed By: CUSTOMER Customer Phone #: 949-547-4650Customer POC: JEREMY KUNZ Wanted Date: ON INSP. Job #: 530000383564 ELECTRIC UNDERGROUND METER & SERVICE LOCATION Customer Copy Project Title: 31242 PASEO OLIVOS SOT OC Notification #: 300000757830 Project Address: 31242 PASEO OLIVOS Customer Type: Residential(1-2 Units) Date Prepared: 01/10/2025 Project City: SAN JUAN CAPISTRANO SDGE Contact: Service Coordinator Contact Info: SERVICE DESK,949-361-8066 Service Type: UG SERVICE REWIRE/RELOCATION TB: 0952-C7 SERVICE ATTACHMENT POINT AND/OR METER LOCATION: Locate the new 200amp meter panel on the North wall at/near the northwest corner, in the existing location. Customer is to provide all excavation, trench, 3" conduit, backfill, compaction, handhole, 3/4" pulling and measuring tape in conduit and surface repair from secondary handhole SH729839 to new meter panel. Take conduit to within distance as instructed by SDG&E inspector. Prior to digging, please contact Dig Alert at 811 to open a ticket. From there, please call the Trench Desk at 949-361-8061 to schedule a pre-trench meeting with your trench inspector. Customer to bring meter cabinet up to standards per SG507. New panel required to be on site for final trench release. SDG&E Application Required-Call: 1-800-411-7343 Municipal Inspection required By: CITY OF SAN JUAN CAPISTRANO Bend Installed By: SDG&E Handhole Installed By: Traffic Control Permit Required Excavation/Encroachment Permits Required By: Joint Trench With: Right of Way Required Meter height -- 4'0'' min. (3'0" min. for multiple installation) -- 6'3" max. From finish grade to centerline of meter base. Meters are required to be readily accessible 24 hours per day. Meters must be located in a safe area free of any potentially hazardous or dangerous condition. Provide 3-ft. x 3-ft. clear and level working space in front of meter. Where meter room is proposed, contact the planner at the nearest SDG&E office. Meter bases and meter service disconnects must be located at or immediately adjacent to each other and be identified with address and unit number. If SDG&E encounters hazardous or toxic material while performing construction of your project, SDG&E will halt work immediately and it will be your responsibility to remove and or clean up all hazardous or toxic material prior to SDG&E continuing construction. SDG&E shall have no liability or obligation whatsoever to cleanup, remove or remediate any hazardous or toxic materials discovered during the course of construction unless it is through negligence of SDG&E. Customer-owned facilities to receive gas service are subject to all applicable local and state of California inspection authority requirements. Building address and/or houseline must be permanently identified prior to meter set. Barrier posts may be required based on field conditions at any time prior to meter set as determined by the SDG&E Representative. Per Rule 16.A.1.a. In compliance with Section 783 of the Public Utilities Code, SDG&E will apply only those construction and design specifications, standards, terms, and conditions that are applicable to a new extension of service project for the 18 months following the date the application for a new extension of service project is approved. Keep this notice with your building permit. All installations performed under this order must meet SDG&E standards unless a written deviation has been approved. Planned By: Shelby McDermott Phone#: 12/02/2024 Casas Capistrano Association, Inc. Architectural Board Decision Notice Mark & Chris Lamont 30761 Marbella Vista San Juan Capistrano, CA 92675 RE: Architectural Application Approval Address: 31242 Paseo Olivos Dear Mark & Chris Lamont: We are pleased to let you know that the architectural application you submitted was approved per the scope of work on your architectural application. The Casa Capistrano Home Owners Association that manages association for the residence at 31242 Paseo Olivos ( Lamont Property ) only requires HOA approval for any modification or construction on the exterior part of the home which is visible from street level per the CC&Rs.Since the homes have 8-10’ foot walls, most if not all of the interior yard and home is not visible. This is why most interior yard and interior home remodeling is not required for HOA approval. The HOA does not require approval for the following: 1.) Interior Remodel or modifications of the interior home and interior yard ( behind 8-10’ walls ). 2.) Replacement of windows, including a swap of the current window above the current atrium. Similar size and general location. 3.) Replacement of Skylights and added skylights on the flat roof. 4.) Added door from master bathroom to exterior yard. ( Cannot be seen from exterior of home ). 5.) And any other remodeling, construction or modifications that cannot be seen from exterior street level view. If you have any questions or need further information, please contact your Owner Services Representative at ownerservicesrepresentative@pmg-oc.com. We thank you for your patience during the architectural process. Regards, Eric Fordyce, On Behalf of Casas Capistrano Association, Inc. Board of Directors HK Environmental, LLC dba Jackson Abatement CSLB: 1077679 DOSH: 1233 202 Fashion Lane, Suite 230, Tustin, CA 92780 949-945-8457 Rich@HKEnvironmental.com Client: Oaks to Oceans Homes, Inc. Completion Letter: Asbestos Abatement Project Address : 31242 Paseo Olivos, San Juan Capistrano, CA Project Information Re port Number: 2410-091-1058802 Report Date: 10/09/2024 Date of Asbestos Abatement: 11/14/2024 Total amount of asbestos removed: 190 Square feet The purpose of this Completion Letter is to certify that the property pertaining to the above Project Address has undergone asbestos abatement, as follows; Removal of drywall joint compound located at hall bathroom, acoustic texture at HVAC, duct wrap at HVAC, transite pipe at roof vent stack. All work was performed by personnel trained in asbestos abatement at an AHERA approved facility. All waste was packaged and disposed of at an EPA approved landfill. Respectfully, ______________________________ Richard C. Jackson Jr. J A C K S O N A B A T E M E N T 11/14/2024 From:Bullum, Ivana To:mark@oakstoocean.com; Building Department Cc:engcounter; Parkinson, Elizabeth; Marti, Pablo Subject:RE: SC - 31242 Paseo Olivos SJC Date:Wednesday, October 2, 2024 9:15:37 AM [The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.] Address 31242 Paseo Olivos, San Juan Capistrano has been cleared by SMWD. There are no impacts to public water and sewer. Thank you, Ivana​​​​ Bullum Temporary Eng Tech O: 949-459-6648 M: 949-804-8986 smwd.com ***** Please note that email correspondence with the City of San Juan Capistrano, along with attachments, may be subject to the California Public Records Act, and therefore may be subject to disclosure unless otherwise exempt.