Loading...
B22-1232 - 31802 AVENIDA EVITA10/18/24 OWNER/BUILDER ATTN: Karla Dalla Torre DATE:EMAIL: APPLICANT/OWNER NAME: JOB ADDRESS: DEVELOPMENT NAME: PHASE: TRACT(s): LOT(s): UNIT(s): CONTACT NAME: CONTACT PHONE: COMPANY NAME: TRACT LOT UNIT TOTAL SQUARE FOOTAGE PREPARED BY:&$0,/2-,0(1(= PHONE: 949-443-63 ADDRESS NEW RESIDENTIAL ROOM ADDIT,ONS CITY OF SAN JUAN CAPISTRANO SCHOOL FEES WORKSHEET COMMERCIAL/INDUSTRIAL CUSD FAX: (949) 493-3728 &-,0(1(=@SANJUANCAPISTRANO.ORG TOTAL SQUARE FOOTAGE PROJECT INFORMATION SQUARE FOOTAGEAPN JAMES KRIEGER 31802 AVENIDA EVITA 7112 5 JAMES KRIEGER 949.795.8613 7112 5 31802 AVENIDA EVITA 649-232-04 867 ✔867 867 4/11/23 1 Building Department From:Parkinson, Elizabeth <betsyp@smwd.com> Sent:Wednesday, June 14, 2023 1:46 PM To: Kriegere; Building Department Cc:Webster, Tanner; engcounter Subject:Sanitation Clearance - 31802 Avenida Evita SJC [The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.] Good afternoon, This address has been cleared by SMWD. There are no impacts to public water and sewer. Thank you, Betsy Parkinson Administrative Assistant O: 949-459-6612 M: 949-433-6933 smwd.com From: Kriegere <kriegere@cox.net> Sent: Wednesday, June 14, 2023 9:53 AM To: engcounter <engcounter@smwd.com> Subject: B22-1232 1) 31802 Avenida Evita, San Juan Capistrano 2) Tract 7112 Lot 5 3) Room addition, adding bedroom, bathroom that includes sink shower and toilet. 4) Plumbing changes described above new sink, shower and toilet. 5) Adding water and sewer for shower, sink and toilet. 6) Connecting to house water and sewer. 7) Jim Krieger (949) 795-8613 ***** Please note that email correspondence with the City of San Juan Capistrano, along with attachments, may be subject to the California Public Records Act, and therefore may be subject to disclosure unless otherwise exempt. You don't often get email from kriegere@cox.net. Learn why this is important 31802 Avenida Evita Jim Krieger 3West Environmental, Inc.Page 1 of 8 3 WEST ENVIRON MEN TAL, IN C. 949-482-1357 info@3westenviro.com https://www.3westenviro.com LIMITE D ASBESTOS SAMPLING REPORT 31802 Aveni da Evi ta San Juan Capi s trano, CA 92675 Ji m K rieger MAY 4, 2023 In spector Ti mothy Maskew CAC, CM I , CDP H -I /A 949-482-1357 info@ 3west env iro .co m 31802 Avenida Evita Jim Krieger 3West Environmental, Inc.Page 2 of 8 TAB LE OF CONTENTS 1: As bestos Detected 2: Requir ements , Recommendations & Limitations 3: P ro to col 4: Cer ticatio ns & Ac c reditatio ns 5: Attachments 3 4 6 7 8 31802 Avenida Evita Jim Krieger 3West Environmental, Inc.Page 3 of 8 Asbestos Detected 3West Env ironmental, I nc. was ret ained by Jim Krieger to conduct Limit ed Asbest os Sampling at 31802 Av enida Ev ita,San Juan Capist rano, CA 92675 due t o suspect ACM being impact ed in t he pro cess of a planned renov at ion act iv it y . The site v isit occurred on 05/04/2023 by t he inspector shown in sect ion 4. Please see sect ion 4 for t he certicat ions of 3West Env ironmental personnel, as well as t he accredit at ions fo r the labo rat o ry used for any sampling. As a result of t he limited Asbest o s Sampling co nducted, it was found t hat asbest o s: W as de t e c t e d on t he materials list ed below and att ached oor plan. The sample lo cat ions list ed are a represent at iv e sampling of t he mat erials in t he structure. M aterials that t est positiv e at >1% asbest os are regulat ed by the EPA, Cal/OSH A, and Sout h Coast AQM D (Rule 1403). M aterials wit h result s <1% asbest os v ia P L M are also regulat ed unless v eried t o cont ain <1% asbest o s v ia 1,000 PointCount acco rding t o t he EP A Applicability Determinat ion Index Cont ro l N umber C112. # Of Bulk Samples Collected 9 Bul k Samp les Areas/Materials Positive for Asbestos H ighlighted M aterials Test ed or Assumed Posit iv e For Asbestos Sampl e ID Mat erial Loca tion Cond/ Fria bl e Asbestos Cont e nt Approx Qty 1 A,B,C Stucco w/Pape r E xt erior G/N F None De tected ~250 SF 2 A,B,C Rolled Roof w/Felt Roof G/N F None De tected ~500 SF 3 A,B,C*Masti c Roof - Penetra tions G/N F 5% Chrysot ile ~20 SF * Some samples wer e not analyzed due to "prior positive series". Accor ding to the AHERA analysis pr otocol as listed in 40 CFR 763.87 (c) (2) A homogeneous ar ea shall be determined to contain ACM based on a nding that the r esults of at least one sample collected fr om that ar ea shows that asbestos is present in an amount greater than 1 percent. 1: ASBESTOS DETECTED Informati on section-NTUyMz RkMTgtM WMxMi 00YjJjLTgxMjYtZDE5N GM2ODhhN TUx 31802 Avenida Evita Jim Krieger 3West Environmental, Inc.Page 4 of 8 Specic A reas This asbest o s sampling was limited to the follo wing areas: St ucco wit h paper on the ext erio r Rolled roof with felt on the roof M astic at the penet rat ions on the roof I f o ther suspect Asbestos Co ntaining M at erials (ACM ) will be dist urbed then these need t o be tested prio r to beingdisturbed or reno v at ed. Structure Hou se Entire Unit: Obvious Structural or Fire Damage, if any N one Observed Levels 1 Foundation Sl ab-on -grade Year Built 1975 Square Footage 1,471 Sketch Attach ed Bulk Sampling Limitations 3West Environmental, Inc. provided limited asbestos sampling of agreed upon areas and materials. Some materials may be hidden, which are not included in this sampling. Further assessment of suspect Asbestos Containing Material (ACM) may be accomplished by a more compr ehensiv e sur v ey. The samples collected for testing ar e believed to be representative of the area(s) evaluated. However, if additional suspect Asbestos Containing Materials are found during renovation or remediation activities, these materials should be sampled by qualied per sonnel, and analyzed for content prior to further disturbance. Quantities of ACM are approximate. These number s should be conrmed prior to r emoval, r epair, or remediation activities.  No warr anty , expressed or implied, is made regar ding the professional opinions pr esented in this report. Var iations in site conditions may exist and conditions not observed or descr ibed in this r eport may be encounter ed during subsequent activities.  Our conclusions, recommendations, and opinions ar e based on an analysis of the obser v ed site conditions. It should be understood that the conditions of a site can change with time as a result of natural processes or the activities of man at the subject site or nearby sites. In addition, changes to the applicable laws, regulations, codes, and standards of practice may occur due to gover nment action or the broadening of knowledge. The ndings of this report may , therefore, be invalidated ov er time, in part or in whole, unless evaluated again. Abatement Contractor Asbest os Con t ain in g Mat e rials we re pre sen t in th e h igh ligh ted m at e rials listed above , a n d m u st be h an dle d by a Californ ia Lic e n se d Asbe stos Aba tem e n t Con t rac tor. Materials that test positive at >1% asbestos are r egulated by the EPA, Cal/OSHA, and South Coast Air Quality Management District (Rule 1403). Materials with r esults <1% asbestos v ia PLM ar e also consider ed >1% asbestos unless veried to contain <1% asbestos via 1,000 Point Count.  Materials with r esults >0.1% asbestos are regulated by Cal/OSHA. Califor nia Code of Regulations Title 16, Division 8, Article 3. Classications  C-22 - Asbestos Abatement Contractor  An asbestos abatement contractor performs abatement, including containment, encapsulation, or removal, and disposal of asbestos containing constr uction materials, as dened in Section 6501.8 of the Labor Code, in and on buildings and str uctures. All wor k per for med and all documentation pr epar ed by an asbestos abatement contractor shall be done in accordance with r egulations and requir ements of the Division of Occupational Safety and Health (DOSH) of the Department of Industrial Relations. Oversight & Clearance 2: REQUIREMENTS, R ECOMMENDATIONS & LIMITATIONS Informati on section-MzN mN Tg 3MWM tN GYwMy00ZGVhLWI1ZDctZTJkZTE2N WY3N WM2 31802 Avenida Evita Jim Krieger 3West Environmental, Inc.Page 5 of 8 It is r ecommended that asbestos abatement oversight be conducted by a State of California Division of Occupational Safety and Health (DOSH) Cer tied Asbestos Consultant (CAC) or Cer tied Site Surveillance Technician (CSST) in accordance with all applicable Federal, State and local regulatory guidelines.  The CAC or CSST should be onsite thr oughout the abatement activ ities, including but not limited to pr epar ation and set up, r emoval activities, nal clean up, and containment tear down. It is also r ecommended that air sampling be conducted thr oughout the asbestos abatement activities by a CAC or CSST in accordance with all applicable guidelines.  The sampling should include, but not be limited to, ambient air samples collected fr om outside the containment befor e the star t of and dur ing abatement activities, and nal air clearance testing from inside the containment upon completion of the abatement activities and passing of a v isual inspection.  It is r ecommended that all air samples be analyzed by an accredited laboratory via Phase Contrast Micr oscopy (PCM), as per National Institute of Occupational Safety and Health (NIOSH) Method 7400.  If nal air clearance samples do not pass (i.e. are not less than 0.01 bers per cubic centimeter s, or f/cc), the wor k area should either be r ecleaned and retested, or the air samples should be reanaly zed via Transmission Electron Microscopy (TEM), as per NIOSH Method 7402.  Upon r eceipt of passing r esults, the containment may be torn down. 31802 Avenida Evita Jim Krieger 3West Environmental, Inc.Page 6 of 8 Testing Protocol: Bulk Sampling Protocol Bulk sampling was in acco rdance with the AH ERA inspectio n pro tocol as list ed in 40 CF R 763.86. 763.86   Sam pling. (a) Surfacing mat erial. An accredit ed inspect o r shall collect, in a stat ist ically random manner t hat is representat iv e ofthe homo geneous area, bulk samples fro m each ho mogeneo us area of friable surfacing material t hat is not assumed t o be ACM , and shall co llect t he samples as follo ws: (1) At least three bulk samples shall be co llect ed from each homogeneous area that is 1,000 ft2 or less, ex cept asprovided in 763.87(c)(2). (2) At least v e bulk samples shall be co llect ed from each ho mogeneo us area that is greater t han 1,000 ft 2 but less t han or equal t o 5,000 ft2, ex cept as prov ided in 763.87(c)(2). (3) At least sev en bulk samples shall be collected fro m each homo geneous area t hat is great er t han 5,000 ft2, ex cept as prov ided in 763.87(c)(2). (b) Thermal sy stem insulat ion. (1) Except as prov ided in paragraphs (b) (2) t hrough (4) of this sect ion and 763.87(c), anaccredited inspect or shall collect, in a rando mly dist ributed manner, at least three bulk samples from eachhomogeneous area of t hermal sy stem insulatio n t hat is not assumed t o be ACM . (2) Co llect at least o ne bulk sample fro m each homo geneous area of pat ched thermal sy st em insulat ion t hat is not assumed to be ACM if t he patched sectio n is less than 6 linear or square feet . (3) In a manner sucient t o det ermine whether t he mat erial is ACM o r no t ACM , co llect bulk samples from each insulated mechanical sy stem t hat is not assumed t o be ACM where cem ent or plast er is used on tt ings such as t ees, elbo ws, or v alv es, ex cept as pro v ided under 763.87(c)(2). (4) Bulk samples are no t required t o be collected fro m any ho mogeneo us area where the accredited inspect or has det ermined that t he t herm al sy stem insulat ion is berglass, fo am glass, rubber, o r o ther non-ACBM . (c) M iscellaneous material. I n a manner sucient t o determine whet her mat erial is ACM o r no t ACM , an accredit edinspector shall collect bulk samples from each ho mogeneo us area o f friable miscellaneous material that is no t assumedto be ACM . (d) N onfriable suspect ed ACBM . I f any ho mogeneous area o f no nfriable suspected ACBM is not assumed t o be ACM , t hen an accredited inspect or shall co llect , in a manner sucient to determine whet her the material is ACM or not ACM ,bulk samples fro m the homogeneo us area of nonfriable suspect ed ACBM t hat is not assumed t o be ACM . Testing Protocol: PLM Analysis Samples were analy zed v ia the EPA recommended m et hod of Polarized Light M icroscopy (PLM ) in acco rdance with EP ATest M et hod 600/R-93/116. Bulk Samples were analy zed in acco rdance wit h t he AH ERA prot o col as listed in 40 CFR 763.87. Testing Protocol: Bulk Limits Asbestos Co ntaining M at erials (ACM ) hav e an asbestos cont ent great er t han 1%. Asbestos Co ntaining Constructio n M aterials (ACCM ) hav e an asbestos cont ent great er than 0.1%. Because of the limit atio ns of P L M analy sis, if t he Bulk Samples analy zed v ia PLM are found t o cont ain <1% asbest o s t hen t his is co nsidered ACM . I n order to be classied as ACCM t hese samples would need t o be analy zed v ia "1,000 P o int Count " and v eried t ocontain <1% asbest o s.  3: PROTOCOL Informati on section-YWFhYmM 2NzM tN TZh OC00N TAxLTkwMj YtOTQxY2I3N TE2NTZm 31802 Avenida Evita Jim Krieger 3West Environmental, Inc.Page 7 of 8 Inspector Certications: CAC This inspec tion & sur vey wer e performed by Timothy Maskew o f 3West Environmental, Inc. CAC Cer t: 22-7195 Exp 10/21/23 This inspection & r epo rt wer e co nsulted & reviewed by Ro ber t Pilzer. CAC Cer t: 96-2024 Exp 9/9/23 Timothy Maskew 205 Avenida Del Mar #210 San Clemente, CA 92674 310-400-0195 Robert P ilz er (hecobp@yahoo.com) 205 Avenida D el Mar #210 San Clemente, CA 92674 562-705-9891 LABS: NVLAP: EMLAB P&K - Tustin, CA N V L AP L ab Code: 200757-0 Eurons EM Lab P &K, LLC 2841 Dow Av enue, Suite 300 Tust in, CA 92780 Dan Shelby Phone: 623-298-1015 Email: dan.shelby @ euronset .co m ht t ps://www.em lab.com/about /accredit at ions/ 4: CER TIFICATIONS & ACCREDITATIONS Informati on section-N2YwZDFjN DEtYj U1MS00ZTIwLTh iZTktNzU5YWY1Yz k2YzMx 31802 Avenida Evita Jim Krieger 3West Environmental, Inc.Page 8 of 8 Attachments Lab Resul ts, Chai n of Cu stody, Fl oor Pl an , NVLAP 5: ATTACHMENTS Informati on section-NWE3MWI3Mj AtOWR jYi 00MDg5LWFlZj UtMGUxNTgzNTJkN2Ni Approved by: Approved Signatory Danny Li Report for: Tim Maskew, Certified Asbestos Consultant 3West Environmental, Inc. 205 Avenida Del Mar #210 San Clemente, CA 92674 Regarding: Eurofins EPK Built Environment Testing, LLC Project: 33333-Asbestos; 31802 Avenida Evita EML ID: 3250705 All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested. Eurofins EPK Built Environment Testing, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor. Dates of Analysis: Asbestos PLM: 05-09-2023 Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267) NVLAP Lab Code 200757-0 EMLab ID: 3250705, Page 1 of 4Eurofins EPK Built Environment Testing, LLC Eurofins EPK Built Environment Testing, LLC 2841 Dow Avenue, Suite 300, Tustin, CA 92780 (866) 888-6653 www.eurofinsus.com/Built Client: 3West Environmental, Inc. C/O: Tim Maskew, Certified Asbestos Consultant Re: 33333-Asbestos; 31802 Avenida Evita Date of Sampling: 05-04-2023 Date of Receipt: 05-04-2023 Date of Report: 05-09-2023 ASBESTOS PLM REPORT Total Samples Submitted:9 Total Samples Analyzed:7 Total Samples with Layer Asbestos Content > 1%:1 Location: 1A, Stucco w/paper, exterior Lab ID-Version‡: 15757466-1 Sample Layers Asbestos Content White Stucco ND Gray Stucco ND Brown/Black Vapor Barrier Paper ND Composite Non-Asbestos Content: 35% Cellulose Sample Composite Homogeneity: Moderate Location: 1B, Stucco w/paper, exterior Lab ID-Version‡: 15757467-1 Sample Layers Asbestos Content White Stucco ND Gray Stucco ND Brown/Black Vapor Barrier Paper ND Composite Non-Asbestos Content: 35% Cellulose Sample Composite Homogeneity: Moderate Location: 1C, Stucco w/paper, exterior Lab ID-Version‡: 15757468-1 Sample Layers Asbestos Content White Stucco ND Gray Stucco ND Brown/Black Vapor Barrier Paper ND Composite Non-Asbestos Content: 35% Cellulose Sample Composite Homogeneity: Moderate EMLab ID: 3250705, Page 2 of 4Eurofins EPK Built Environment Testing, LLC The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC 2841 Dow Avenue, Suite 300, Tustin, CA 92780 (866) 888-6653 www.eurofinsus.com/Built Client: 3West Environmental, Inc. C/O: Tim Maskew, Certified Asbestos Consultant Re: 33333-Asbestos; 31802 Avenida Evita Date of Sampling: 05-04-2023 Date of Receipt: 05-04-2023 Date of Report: 05-09-2023 ASBESTOS PLM REPORT Location: 2A, Rolled roof w/felt, roof Lab ID-Version‡: 15757469-1 Sample Layers Asbestos Content Black Roofing Shingle with Pebbles ND Black Roofing Felt ND Black Roofing Tar ND Composite Non-Asbestos Content: 30% Cellulose 20% Glass Fibers Sample Composite Homogeneity: Moderate EMLab ID: 3250705, Page 3 of 4Eurofins EPK Built Environment Testing, LLC The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC 2841 Dow Avenue, Suite 300, Tustin, CA 92780 (866) 888-6653 www.eurofinsus.com/Built Client: 3West Environmental, Inc. C/O: Tim Maskew, Certified Asbestos Consultant Re: 33333-Asbestos; 31802 Avenida Evita Date of Sampling: 05-04-2023 Date of Receipt: 05-04-2023 Date of Report: 05-09-2023 ASBESTOS PLM REPORT Location: 2B, Rolled roof w/felt, roof Lab ID-Version‡: 15757470-1 Sample Layers Asbestos Content Black Roofing Shingle with Pebbles ND Black Roofing Felt ND Black Roofing Tar ND Composite Non-Asbestos Content: 30% Cellulose 20% Glass Fibers Sample Composite Homogeneity: Moderate Location: 2C, Rolled roof w/felt, roof Lab ID-Version‡: 15757471-1 Sample Layers Asbestos Content Black Roofing Shingle with Pebbles ND Black Roofing Felt ND Black Roofing Tar ND Composite Non-Asbestos Content: 30% Cellulose 20% Glass Fibers Sample Composite Homogeneity: Moderate Location: 3A, Mastic, roof - penetrations Lab ID-Version‡: 15757472-1 Sample Layers Asbestos Content Black Roofing Mastic 5% Chrysotile Sample Composite Homogeneity: Good Comments:Samples 3B and 3C were not analyzed due to prior positive series. EMLab ID: 3250705, Page 4 of 4Eurofins EPK Built Environment Testing, LLC The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". LF ZS 3WEST = Reee (weeeeeee :?\ poepeed coo + { | ain i f { { t | wba oe:4 i pote ENVIRONMENTAL,INC T | 4 t | i 1 | Coes ae oo 4p 4p 4 r 4 = | yo ? ae jt Pte ET _ Pt iity aa Litt te itttt |iHoytd444qo booedEpeeeE anane,mabPsijttLcedoopolEdioto rei1otL!ALfme|GidleyBetof__ United States Department of Commerce National Institute of Standards and TechnologyCertificate of Accreditation to ISO/IEC 17025:2017NVLAP LAB CODE: 200757-0Eurofins EMLab P&KTustin, CAis accredited by the National Voluntary Laboratory Accreditation Program for specific services, listed on the Scope of Accreditation, for:Asbestos Fiber Analysis2023-01-01 through 2023-12-31Effective DatesFor the National Voluntary Laboratory Accreditation ProgramThis laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communique dated January 2009). SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 Page 1 of 1 For the National Voluntary Laboratory Accreditation Program Effective National Voluntary Laboratory Accreditation Program 2023-01-01 through 2023-12-31 Eurofins EMLab P&K 2841 Dow Avenue, Suite 300 Tustin, CA 92780 Dan Shelby Phone: 623-298-1015 Email: dan.shelby@et.eurofinsus.com http://www.emlabpk.com ASBESTOS FIBER ANALYSIS NVLAP LAB CODE 200757-0 Bulk Asbestos Analysis Code Description 18/A01 EPA -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples 18/A03 EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials Airborne Asbestos Analysis Code Description 18/A02 U.S. EPA's "Interim Transmission Electron Microscopy Analytical Methods-Mandatory and Nonmandatory-and Mandatory Section to Determine Completion of Response Actions" as found in 40 CFR, Part 763, Subpart E, Appendix A.