B23-0132 - 28662 AVENIDA PLACIDACITY OF SAN JUAN CAPISTRANO
BUILDING PERMIT
Permit No. B23-0132
11/01/2023
ISSUED
JOB VALUE
NO UNITS
Permit Number
ISSUED BY
SITE APN
SITE LOT NO
SITE TRACT
SITE SUBDIVISION
PERMIT TYPE.
OCCUPANCY TYPE
BUILDING SF
NO STORIES
DF4
666-511-04
3
13437
$ 24,000
SOLAR PANEL INSTALLA
0
0
0
JOB ADDRESS: 28662 AVENIDA PLACIDA
ZHANG & ZHOU, TONY & YUNQINGOWNER NAME
28662 AVENIDA PLACIDAMAILING ADDRESS
CITY,STATE,ZIP
CONTRACTOR NAME
ST. LIC EXPIRE
ADDRESS
CITY, ST, ZIP
TENANT NAME
PHONE #
MAILING ADDR
CITY, ST, ZIP
I have carefully examined the completed permit application and do hereby certify under penalty of
perjury that all information hereon including the declarations are true and correct and I further
certify and agree if a permit is issued: to comply with all City, County, and State laws governing
building construction, whether specified herein or not. I also agree to save, indemnify and keep
harmless the City of San Juan Capistrano against all liabilities, judgments, costs and expenses
which may in any way accrue against said City in consequence of the granting of this permit.
Applicant's signature
Owner/Contractor
Print Name
SUN BEES GROUPS INC
201 CLARK AVE
03/31/2024
AMOUNT
MECHANICAL PERMIT AMOUNT
Expiration:: Every permit issued shall become invalid unless the work on the site authorized by
such permit is commenced within 12 months after its issuance, or if the work authorized on the
site by such permit is suspended or abandoned for a period of 180 days after the time the work
commenced.
An OSHA permit is required for excavations over 5’0” deep and demolition or construction of
structures over 3 stories in height.
_____Contractor:I hereby affirm that I am licensed under provisions of Chapter 9 of Division 3 of the Business and Professions Code, and my license is in full force and effect.
_____Owner/Builder:I, as owner of the property, or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale. (Sec.7044, Business and Professions
Code: the Contractor’s License Laws does not apply to and owner of property who builds or improves thereon, who does such work himself or through his employees, provided that such improvements are not
intended or offered for sale. If however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
______Owner/Builder:I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor’s License Law does not
apply to an owner of property who builds or improves thereon and who contracts for such projects with a contractor’s) license pursuant to the Contractor’s License Law.
_______ Workers Compensation-I hereby affirm under penalty of perjury one of the following declarations:I have and will maintain workers’ compensation insurance, as required by Section 3700 of the
Labor Code, for the performance of the work for which this permit is issued. My workers’ compensation insurance carrier and policy number are: Carrier__STATE COMPENSATION INSURANCE
FUND Policy#9147686 (This section needs to be completed if the permit is for one hundred dollars($100) or less)
AMOUNTELECTRICAL PERMIT
DESCRIPTION
_______Exemption:I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers’ compensation laws of
California and agree that if I should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions.
WARNING:FAILURE TO SECURE WORKERS’COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TI CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED
THOUSDAND DOLLARS($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
B23-0132
Total Electrical
Total Plumbing
Total Mechanical
Total Mobile Home
970591
,
POMONA, CA 91767
SAN JUAN CAPISTRANO, CA 92675
(818) 698-1688
(714) 676-8888
PHONE
PHONE
Date _________________ Applicant _______________________________________
MOBILE HOME PERMIT AMOUNT
24 ROOF MOUNTED SOLAR PANELS. 8.76kW AC SYSTEM.
PLUMBING PERMIT
Maochen Chang
MC
MC
Maochen Chang
FINAL
12/04/2023
Date:
Permit No.
Ap plicant:
Phone/E-Mail
Job Location:
CITY OF SAN JUAN CAPISTRANO
BUILDING PERMIT FEES
Account #Type Cost
01-44221 Building Permit
01-44223 Mechanical
01-44224 Plumbing
01-44225 Electrical
01-44221 Mobile Home Permit
01-44222 Grading Permit Fee
01-44231 Grading Plan Check
01-44222 On-Site Residential Permit
01-44231 On-Site Residential Plan Check
Subtotal
01-44230 Bond Processing
01-44230 Building Plan Check
01-44230 Additional Plan Check
01-44230 Digital Record Fee ($1.00 per sheet)
01-44221 C & D Administrative Fee
01-44221 Special Inspection-Reinspection
01-44222 On-Site Commercial/Tract Permit Fee
01-44231 On-Site Commercial/Tract Plan Check Fee
01-44214 Geotechnical Soils Plan Review
10-44320 Ordinance 211
10-42510 Ordinance 364
01-45354 Copies @ .20 Each
90-23331 SMIP Fee
33-44370 H.O.P.E. Fee (Housing in Lieu)
Other Fees
TCA Fees Date Received
HOA Approval Date Received
School Fees Date Received
Engineering Fees Date Received
Water Division Fees Date Received
01-44221
01-44221
01-44240
90-23000
90-23000
TOTAL FEES PAYABLE TO CITY OF SAN JUAN CAPISTRANO
Receipt # _________ Date: ______________ Cashier: _____________________________
Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type
Title 24 Energy Provision (20% Permit Subtotal & Bldg Plan Check))
Title 24 ADA Fee (10% Permit Subtotal & Bldg Plan Check)
Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type
NPDES Permit Fee (10% Permit Subtotal)
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
11/1/2023
$0.00
$0.00
$0.00
11/1/2023
B23-0132
SUN BEES GROUPS INC
28662 AVENIDA PLACIDA
(909) 753-3178
$0.00
Maochen Chang
B23 0132
09 2308
DC
8.76kW AC
NO MPU/BBU
24,000
/ SUN BEES
GROUPS INC
GENERAL REQUIREMENTS
Y N
Y N
Y N
Y N
1.System size is 10 kW rating or less
2.Solar array is roof mounted on a one or two family dwelling OR accessory dwelling unit (ADU)
3.Solar panels/module arrays will not exceed the maximum legal building height
4.Solar system is utility interactive and without battery storage
5. New roofing material directly below the solar array may be installed by a separate roofing contractor
or the solar installation contractor. Any roofing outside of the array footprint will require a separate
permit from a licensed roofing contractor.
RESIDENTIAL PHOTOVOLTAIC
ELIGIBILITY CHECKLIST
Solar Photovoltaic (PV) Checklist for
Detached One- or Two- Family Dwellings
Instructions: The licensed contractor of record shall fill in the address of the project, contractor’s licensing
information and answer each statement with Y or N. Complete and sign the certification section.
** If any items are checked NO, plan check shall be required **
Project Address: ___________________________________________________
Contractor Company Name: ____________________________________________________
Contractor State License Number: ____________________________________________________
City of SJC Business License Number: _________________________________
City of San Juan Capistrano
DeDevelopment Services Department
32400 Paseo Adelanto
San Juan Capistrano, CA 92675
Phone: (949) 443-6347
Email: building@sanjuancapistrano.org
www.sanjuancapistrano.org/building
07/03/23 LL
1.Permit Application (Completed & Attached)
2.Signed Contract or letter of intent with the homeowner is provided with submittal
3.Structural Roof Criteria and supporting documentation is attached and stamped by a licensed design
professional
4.Electrical load calculation is required for all installations. (MUST BE COMPLETED ON CITY STANDARD
TEMPLATE)
5.SDG&E Work Order is required for all Main Panel Upgrades
6.Clear photographs required of existing main service panel and subpanels showing ALL circuit breakers/
loads and panel board/bus ratings.
7.Manufacturers Specifications required for ALL electrical components that will be installed
Y N
Y N
Y N
Y N
Y N
Y N
Y N
STRUCTURAL REQUIREMENTS
1.A completed Structural Criteria and supporting documentation is attached and stamped by a licensed
design professional for solar array attachment and/or any separate structure or racking supporting array
or equipment.
Y N
Y N
CITY SPECIFIC REQUIREMENTS
28662 Avenida Placida, San Juan Capistrano, CA 92675
True Power Solar
970591
75023
FIRE SAFETY REQUIREMENTS
1.Clear access pathways provided per OCFA and CRC guidelines
2.Fire classification solar system is provided (Class A)
3.All required markings and labels are provided
4.Diagram of the roof layout of all panels, modules, clear access pathways and approximate
locations of electrical disconnecting means and roof access points is completed and
attached
**Renewable Meter Adapter (RMA) installations must be approved by SDG&E and have a separate GEC. Any and all grounding work not performed by SDG&E, including but not limited to the RMA disconnect, will be performed by the Solar Contractor.
I certify under penalty of perjury under the laws of the State of California that the above is true and
correct. I understand that all approvals are subject to field inspection. Field corrections may
require a formal revision submitted for plan review. A re-inspection fee may be assessed when
work is not ready, inspection card and/or approved plans are not available, no access has been
provided or there is any deviation from the approved plans.:
Print Name: ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ Date: ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ
Signature: ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ
Phone Number:ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ
Email Address: ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ
ELECTRICAL REQUIREMENTS
1.The PV system is interconnected to a single-phase AC service panel of nominal 120/220 Vac with
a bus bar rating of 225A or greater
2.The PV system is connected to the load side of the utility distribution equipment**
3.A Solar PV Standard Plan and supporting documentation is completed and attached
Y N
Y N
Y N
Y N
Y N
Y N
Y N
Maochen Chang
(714)676-8888
operations@truepowersolar.com
9/12/23
Maochen Chang
Page 1/3
RESIDENTIAL ELECTRICAL
LOAD CALCULATION
INSTRUCTIONS: Review the electrical loads in the table below and check all that exist in the home
(be sure to include the proposed Level 2 EVCE and/or Photovoltaic System). Fill in the corresponding
wattage for each item checked, and then add up all the checked items to determine total wattage used.
Wattages shown are rough estimates: for a more precise analysis use actual values based on nameplate
ratings or consult with an electrical professional.
PROJECT ADDRESS:
_______________________________________________________________________________
STATEMENT OF COMPLIANCE:
By my signature, I attest that the information provided is true and accurate.
Name of Applicant: _________________________________________________________________
(Print Name)
Signature: __________________________________ __________
(Signature of Applicant) (Date)
Note: This form is a voluntary compliance alternative and you may wish to hire a qualified individual or
company to perform a thorough evaluation of your electrical service capacity in lieu of this
methodology. Use of this electrical load calculation worksheet is at the user’s risk and carries no implied
guarantee of accuracy. Users of this form are advised to seek professional assistance in determining the
electrical capacity of a service panel.
(Only for Service Ratings of 120/240V, 225 Amps Max)
City of San Juan Capistrano
DeDevelopment Services Department
32400 Paseo Adelanto
San Juan Capistrano, CA 92675
Phone: (949) 443-6347
Email: building@sanjuancapistrano.org
www.sanjuancapistrano.org/building
LL 05/15/23
28662 Avenida Placida, San Juan Capistrano, CA 92675
09.14.2023
Tony Haodong Zhang
Maochen Chang
DIANNA F.11/01/23
B23-0132
SUBJECT TO FIELD INSPECTION
Page 2/3
Check All
Applicable
Description of Load Volt-Amps on
Nameplate Rating
(Watts) Volt-Amps
Used
General Lighting/Power Load
Required Total Square footage of building times 3 sf x 3 volt-amp
Required Kitchen Small Appliance Branch Circuits
(min. 2)
1,500 volt-amps/circuit
Required Laundry Circuit (min. 1) 1,500 Volt-Amps
Appliances and Equipment Except Air Conditioner(s)
Microwave 1,400 watts
Trash Compactor 1,000 watts
Dishwasher 1,500 watts
Disposal 1,000 watts
Electric Oven 2,000 watts
Electric Range 5,000 watts
Induction Range 10,000 watts
Electric Clothes Dryer 4,000 watts
Electric Clothes Washer 500 watts
Electric Tankless Water Heater 15,000 watts
Electric Water Heater 4,000 watts
Electric Heat Pump Water Heater 550 watts
Required on new
homes
Electric Vehicle Supply Equipment (EVSE) 7,000 watts
Evaporative Cooler 500 watts
Pool or Spa 2,000 watts
Other:
Other:
Other:
Sub-Total Volt-Amps Used (add up V-A used for everything checked)
- 10,000 V-A
Subtotal (A)
x .40
Subtotal (B)
+ 10,000 V-A
Subtotal (C)
Heating and Air-Conditioning (Add the largest of the following): +
1. Air conditioning and cooling (100% of nameplate (NP) rating) =
2. Heat pump without supplemental heating (100% NP Rating) =
3. Heat pump with supplemental electric heat (100% NP plus 65%) =
4. Electrical space heating , 4 separate units (65% NP rating) =
5. Electrical space heating > 4 separate units (40% NP rating) =
6. Electrical thermal storage and other 100% NP rating =
Total Current Demand (Volt-Amps) =
Divided by 240 Volts = Amps
Total Amps Required for Service Conductors and Panel =
Rating of Existing Electrical Service or Subpanel (Amps)=
Panel Upgrade Required? (YES OR NO)
Rating of Proposed Electrical Service or Subpanel (IF YES ABOVE)=
watts
watts
watts
LL 05/15/23
10,863
3,000
1,500
1,400
1,500
1,000
2,000
5,000
4,000
2,000
32,263
22,263
8,905
18,905
7,200
26,105
225
NO
109
4
4
4
4
4
4
4
3,621
109
Panel Schedule
Panel ID
Panel Location
Fed From
Amps Single Phase
Three Phase
Main Breaker
Main Lugs Only
Fed-thru Lugs
Breaker Details Phase TypeGeneral Information
Notes
Brkr Pole Wire
(AWG)
Pipe
Size
VA Voltage Description Ckt Ckt Description Voltage VA Pipe Size Wire Size
(AWG)
Pole Brkr
120 / 240
120 / 208
277/ 480
Voltage Type
120 / 240 1
120 / 240 3
120 / 240 5
120 / 240 7
120 / 240 9
120 / 240 11
120 / 240 13
120 / 240 15
120 / 240 17
120 / 240 19
120 / 240 21
120 / 240 23
120 / 240 25
120 / 240 27
120 / 240 29
120 / 240 31
120 / 240 33
120 / 240 35
120 / 240 37
120 / 240 39
120 / 240 41
2 120 / 240
4 120 / 240
6 120 / 240
8 120 / 240
10 120 / 240
12 120 / 240
14 120 / 240
16 120 / 240
18 120 / 240
20 120 / 240
22 120 / 240
24 120 / 240
26 120 / 240
28 120 / 240
30 120 / 240
32 120 / 240
34 120 / 240
36 120 / 240
38 120 / 240
40 120 / 240
42 120 / 240
28662 AVENIDA PLACIDA,
SAN JUAN CAPISTRANO, CA 92675
ZHANG, TONY HAODONG
Prepared For:
TRUE POWER SOLAR
201 CLARK AVE.
POMONA, CA 91767
(714) 676-8888
Design Criteria
1- Code: CALIFORNIA BLDG CODE 2022 / ASCE 7-16
2 - Wind: 110 MPH, Exposure: C
3 - Wood Species: DF-L No. 2 (SG = 0.5 )
Notice: Use restrictions of these calculations.
The attached Calculations are valid only when bearing original signature hereon.
Contractor/Client to verify existing dimensions/conditions prior to construction
& solar racking is installed per manufacturer span requirements.
The use of these calculations is solely intended for the above mentioned project.
10/9/2023
Structural Calculations for
SOLAR POWER SYSTEM CONNECTION CHECK AT:
Job:
1-844-PV ELITE | info@yoursolarplans.com
3000 E. Birch Street Suite 201 | Brea CA 92821
ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes.
Roof Slope =23 °
Roof Shape Gable
Tributary Width s =6.00 ft
Tributary Length l =3.08 ft
Effective Area Ae =10.28 ft2
Height of Structure h =25 ft
Wind Speed V =110 mph
Exposure Category C
Building Width B =40 ft
Building Length L =55 ft
Zone Width a =4ft
Elevation Height zg =343 ft
Wind Directionality Kd =0.85
Topography Factor Kt =1.00
Ground Elevation Factor Ke =0.99
Velocity Pressure Exposure Coefficient Kz =0.95
Velocity Pressure qz = 0.00256KzKztKdKeV2 =24.58 psf
Solar Array Pressure Equalization a =0.80
Array Edge Factor E =1.50
Zone GCp p = qz(GCp)(E)(a)
3--
3r 3.35 -98.80
3e 2.50 -73.56
2--
2r 2.50 -73.56
2e - -
2n 2.50 -73.56
1--
1' - -
LAG SCREW ANALYSIS
Loads
Wind Pressures qz =-73.56 psf
Solar Panel Load QD =3 psf
Panel Length l =6.167 ft
Panel Width b 3.425 ft
Attachment Spacing s =6ft
Portrait
Tributary Area At =18.50 ft2
Wind Load PW = qz * At =-1361 lbs
Dead Load PD = QD * At =55.5 lbs
Uplift Pa = 0.6 PD + 0.6 Pw =-783 lbs
Landscape
Tributary Area At = b * s =10.275 ft2
Wind Load PW = qz * At =-756 lbs
Dead Load PD = QD * At =30.825 lbs
Uplift Pa = 0.6 PD + 0.6 Pw =-435 lbs
Lag Screw
Specific Gravity of Lumber SG =0.50 (Douglas Fir-Larch)
Diameter of Lag Screw D =5/16 in
Withdraw Design /in 1800*SG3/2*D3/4 =266 lbs/in
Depth of Embedment lp =2.50 in
Total Nominal Withdrawal Value W = W * l p =665 lbs
Load Duration Factor CD =1.6
Withdrawal Design Value W' = W * C D =1064 lbs
Demand Capacity Ratio DCR = Pa / W'=0.74 < 1 OK
ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check
Roof Slope =23 °
Roof Shape Gable
Tributary Width s =2.00 ft
Tributary Length L =22.00 ft
Effective Area A = L ( MAX [ s , L/3] )=100 ft2
Height of Structure h =25 ft
Wind Speed V =110 mph
Exposure Category C
Building Width B =40 ft
Building Length L =55 ft
Zone Width a =4ft
Elevation Height zg =343 ft
Wind Directionality Kd =0.85
Topography Factor Kt =1.00
Ground Elevation Factor Ke =0.99
Velocity Pressure Exposure Coefficient Kz =0.95
Velocity Pressure qz = 0.00256KzKztKdKeV2 =24.58 psf
Internal Pressure Coefficient (GCpi)=-0.18
Zone GCp
p = qz [(GCp) - (Gcpi)]
3--
3r 1.80 -48.67
3e 1.66 -45.33
2--
2r 1.66 -45.33
2e - -
2n 1.66 -45.33
1--
1' - -
Beam/ Top Chord Check Lumber:
Moment Demand
# of Attachment per Rafter NA =Span :Orientation
Lenght (ft) :
Dead Load Roof Material:QD =psf
Live Load QLr =psf
Wind Load p = psf
Snow Load QS =psf
Rafter Spacing s = in
Wind Load, Portrait Portrait UL =
Wind Load, Landscape Landscape UW =
Linear Dead Load wd =plf
Live Load wLr = plf Start ft Start ft
End ft End ft
Snow Load ws = plf Start ft Start ft
End ft End ft
Ma, Moment
D lb-ft
D+Lr lb-ft
D+S lb-ft
0.6D+0.6W lb-ft
D+0.45W+0.75Lr lb-ft
D+0.45W+0.75S lb-ft
Moment Capacity Framing Member Size Lumber Grade : DF-L No. 2
CM = 1 Ct = 1 Cr=CF = fb =psi Cfu =Ci =
Breadth b = in
Depth d = in
Section Modulus Sx = bd 2 / 6 =in3
Bending Stress Capacity Fb = CM * Ct * Cr * C F * fb =psi Table 4.3.1 NDS 2018
Deflection Limit E = ksi I =in4
Transient Deflection in
Transient Deflection Allowed >[OKAY]
Total Deflection in
Total Deflection Allowed >[OKAY]
1.0 1
20
0.00
24
TILE
0.241
349 180
1.6 2484 psi D+0.45W+0.75S 1085 psi 0.44 OKAY
1.6 2484 psi D+0.45W+0.75Lr 1085 psi 0.44 OKAY
1.6 2484 psi
0.260
323 120
1600 5.36
0.6D+0.6W 1965 psi 0.79 OKAY
1.15 1785 psi D+S 888 psi 0.50 OKAY
OKAY
1.25 1941 psi D+Lr 968 psi 0.50 OKAY
DCR
0.9 1397 psi D 888 psi 0.64
3.06
1553
CD Fb' = CD * Fb ASD Load Ma / Sx
2x4
1.15 1.5
22.00
19.76
22.00
900
1.50
3.50
227
247
227
501
277
277
0
0.0
0
4
0
0
0.0
Portrait
4
0.0Portrait0 0.0 0.0
AT (ft2)
18.5
10.275
pd (lbs)
55.5 -839
pw (lbs) ps (lbs)
0
19.7640
0.0 0.0 0.0 0.0
0 0.0
Portrait 0
0.030.825 -466 0
-839 0.0Portrait5 14.4 55.5 -839
0.0
34
1234Eave
2
0.0
0.0 0.0 0.0
0.0
0 0.0 0.0 0.0 0.0
0 0.0 0.0 0.0
0.0
6 19.0 55.5
0.0
7.00 7.00 7.00 0.00 1.00
Portrait 3 8.2 55.5
17.00
-45.33
DF-L No. 2
6 j lj (ft)pd,j (lbs) pw,j (lbs) ps,j (lbs)
Landscape 1 4.7 30.8 -466 0.0
6.8 30.8 -466
-839 0.0
4 12.8 55.5 -839 0.0
𝑴𝒙ൌ𝑹𝒊ሺ𝒙െ𝑳𝒊ሻെ𝑷𝒋𝒙െ𝒍𝒋െ 𝒘𝒅𝒙𝟐
𝟐
‐600.0
‐400.0
‐200.0
0.0
200.0
400.0
600.0
0.000 5.000 10.000 15.000 20.000 25.000
EISMIC WEIGHT COMPARISON / ANALYSIS - (PER CEBC 2022 Part 10 Chapter 5 Section 502.5)
PV System Weight
Module Model HANWHA
Panel Weight W panel = 48.5 lbs
Number of Panels NPV =24
Total PV System Weight W PV = W panel * NPV =1164 lbs
Existing Roof Weight
Roof Weight QD =17.0 psf
Building Length Lbuild =55 ft
Building Width W build =40 ft
Roof Area Abuild =2200 ft2
Building Perimeter Pbuild =190 ft
Wall Height ht =8ft
Wall weight Qwall =15 psf
Interior wall weight Qint =10 psf
Roof Load W floor = Abuild * QD =37400 lbs
Wall LoadW wall = ht /2 * Qwall * Pbuild + Abuild * Qint /2 =22400 lbs
Total Story Weight W build = W floor + W wall =59800 lbs
Percentage Weight Increase WPV / Wbuild = 1.95% < 10% OKAY