Loading...
B23-0525 - 33562 VIA DE AGUACITY OF SAN JUAN CAPISTRANO BUILDING PERMIT Permit No. B23-0525 08/31/2023 ISSUED JOB VALUE NO UNITS Permit Number ISSUED BY SITE APN SITE LOT NO SITE TRACT SITE SUBDIVISION PERMIT TYPE. OCCUPANCY TYPE BUILDING SF NO STORIES DF4 675-161-05 32 8319 $ 19,523 SOLAR PANEL INSTALLA 0 2 0 JOB ADDRESS: 33562 VIA DE AGUA TAYLOR, HEATHER TOWNER NAME 33562 VIA DE AGUAMAILING ADDRESS CITY,STATE,ZIP CONTRACTOR NAME ST. LIC EXPIRE ADDRESS CITY, ST, ZIP TENANT NAME PHONE # MAILING ADDR CITY, ST, ZIP I have carefully examined the completed permit application and do hereby certify under penalty of perjury that all information hereon including the declarations are true and correct and I further certify and agree if a permit is issued: to comply with all City, County, and State laws governing building construction, whether specified herein or not. I also agree to save, indemnify and keep harmless the City of San Juan Capistrano against all liabilities, judgments, costs and expenses which may in any way accrue against said City in consequence of the granting of this permit. Applicant's signature Owner/Contractor Print Name BETTER EARTH ELECTRIC INC 16720 MARQUARDT AVENUE 03/31/2025 AMOUNT MECHANICAL PERMIT AMOUNT Expiration:: Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work commenced. An OSHA permit is required for excavations over 5’0” deep and demolition or construction of structures over 3 stories in height. _____Contractor:I hereby affirm that I am licensed under provisions of Chapter 9 of Division 3 of the Business and Professions Code, and my license is in full force and effect. _____Owner/Builder:I, as owner of the property, or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale. (Sec.7044, Business and Professions Code: the Contractor’s License Laws does not apply to and owner of property who builds or improves thereon, who does such work himself or through his employees, provided that such improvements are not intended or offered for sale. If however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) ______Owner/Builder:I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor’s License Law does not apply to an owner of property who builds or improves thereon and who contracts for such projects with a contractor’s) license pursuant to the Contractor’s License Law. _______ Workers Compensation-I hereby affirm under penalty of perjury one of the following declarations:I have and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers’ compensation insurance carrier and policy number are: Carrier__TECHNOLOGY INSURANCE COMPANY INC Policy#TWC4102876 (This section needs to be completed if the permit is for one hundred dollars($100) or less) AMOUNTELECTRICAL PERMIT DESCRIPTION _______Exemption:I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California and agree that if I should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING:FAILURE TO SECURE WORKERS’COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TI CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSDAND DOLLARS($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. B23-0525 SERVICES: < 600V & < 200 AMPS 33.78 ELECTRICAL ISSUANCE FEE 27.24 Total Electrical 61.02 Total Plumbing Total Mechanical Total Mobile Home 1024460 , CERRITOS, CA 90703 SAN JUAN CAPISTRANO, CA 92675 (888) 373-9379 PHONE PHONE MOBILE HOME PERMIT AMOUNT 27 ROOF MOUNTED SOLAR PANELS. 7.60kW AC. 125a MPU PLUMBING PERMIT Better Earth Electric m.o m.o Date ___________ ______ Applicant _______________________________________ REV 1 11/07/2023 FINAL 12/07/2023 Date: Permit No. Applicant: Phone/E-Mail Job Location: CITY OF SAN JUAN CAPISTRANO BUILDING PERMIT FEES Account # Type Cost 01-44221 Building Permit 01-44223 Mechanical 01-44224 Plumbing 01-44225 Electrical 01-44221 Mobile Home Permit 01-44222 Grading Permit Fee 01-44231 Grading Plan Check 01-44222 On-Site Residential Permit 01-44231 On-Site Residential Plan Check Subtotal 01-44230 Bond Processing 01-44230 Building Plan Check 01-44230 Additional Plan Check 01-44230 Digital Record Fee ($1.00 per sheet) 01-44221 C & D Administrative Fee 01-44221 Special Inspection-Reinspection 01-44222 On-Site Commercial/Tract Permit Fee 01-44231 On-Site Commercial/Tract Plan Check Fee 01-44214 Geotechnical Soils Plan Review 10-44320 Ordinance 211 10-42510 Ordinance 364 01-45354 Copies @ .20 Each 90-23331 SMIP Fee 33-44370 H.O.P.E. Fee (Housing in Lieu) Other Fees TCA Fees Date Received HOA Approval Date Received School Fees Date Received Engineering Fees Date Received Water Division Fees Date Received 01-44221 01-44221 01-44240 90-23000 90-23000 TOTAL FEES PAYABLE TO CITY OF SAN JUAN CAPISTRANO Receipt # _________ Date: ______________ Cashier: _____________________________ Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type Title 24 Energy Provision (20% Permit Subtotal & Bldg Plan Check)) Title 24 ADA Fee (10% Permit Subtotal & Bldg Plan Check) Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type NPDES Permit Fee (10% Permit Subtotal) $0.00 $ 61.02 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $6.10 $ 138.23 11/6/2023 $ 205.35 $0.00 $ 61.02 11/6/2023 B23-0525 BETTER EARTH ELECTRIC INC 33562 VIA DE AGUA 95804 (323) 523-7379 $0.00 1DIANNA F.11/06/23OTCXXXXXX1DIANNA F.11/06/2023*REPRINT JOB CARD & PERMIT* CITY OF SAN JUAN CAPISTRANO BUILDING PERMIT Permit No. B23-0525 08/31/2023 ISSUED JOB VALUE NO UNITS Permit Number ISSUED BY SITE APN SITE LOT NO SITE TRACT SITE SUBDIVISION PERMIT TYPE. OCCUPANCY TYPE BUILDING SF NO STORIES DF4 675-161-05 32 8319 $ 19,523 SOLAR PANEL INSTALLA 0 2 0 JOB ADDRESS: 33562 VIA DE AGUA TAYLOR, HEATHER TOWNER NAME 33562 VIA DE AGUAMAILING ADDRESS CITY,STATE,ZIP CONTRACTOR NAME ST. LIC EXPIRE ADDRESS CITY, ST, ZIP TENANT NAME PHONE # MAILING ADDR CITY, ST, ZIP I have carefully examined the completed permit application and do hereby certify under penalty of perjury that all information hereon including the declarations are true and correct and I further certify and agree if a permit is issued: to comply with all City, County, and State laws governing building construction, whether specified herein or not. I also agree to save, indemnify and keep harmless the City of San Juan Capistrano against all liabilities, judgments, costs and expenses which may in any way accrue against said City in consequence of the granting of this permit. Applicant's signature Owner/Contractor Print Name BETTER EARTH ELECTRIC INC 16720 MARQUARDT AVENUE 03/31/2025 AMOUNT MECHANICAL PERMIT AMOUNT Expiration:: Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work commenced. An OSHA permit is required for excavations over 5’0” deep and demolition or construction of structures over 3 stories in height. _____Contractor:I hereby affirm that I am licensed under provisions of Chapter 9 of Division 3 of the Business and Professions Code, and my license is in full force and effect. _____Owner/Builder:I, as owner of the property, or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale. (Sec.7044, Business and Professions Code: the Contractor’s License Laws does not apply to and owner of property who builds or improves thereon, who does such work himself or through his employees, provided that such improvements are not intended or offered for sale. If however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) ______Owner/Builder:I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor’s License Law does not apply to an owner of property who builds or improves thereon and who contracts for such projects with a contractor’s) license pursuant to the Contractor’s License Law. _______ Workers Compensation-I hereby affirm under penalty of perjury one of the following declarations:I have and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers’ compensation insurance carrier and policy number are: Carrier__TECHNOLOGY INSURANCE COMPANY INC Policy#TWC4102876 (This section needs to be completed if the permit is for one hundred dollars($100) or less) AMOUNTELECTRICAL PERMIT DESCRIPTION _______Exemption:I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California and agree that if I should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING:FAILURE TO SECURE WORKERS’COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TI CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSDAND DOLLARS($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. B23-0525 SERVICES: < 600V & < 200 AMPS 33.78 ELECTRICAL ISSUANCE FEE 27.24 Total Electrical 61.02 Total Plumbing Total Mechanical Total Mobile Home 1024460 , CERRITOS, CA 90703 SAN JUAN CAPISTRANO, CA 92675 (888) 373-9379 PHONE PHONE Date _________________ Applicant _______________________________________ MOBILE HOME PERMIT AMOUNT 29 ROOF MOUNTED SOLAR PANELS. 7.60kW AC. 125a MPU PLUMBING PERMIT Better Earth Electric M.O M.O Date: Permit No. Applicant: Phone/E-Mail Job Location: CITY OF SAN JUAN CAPISTRANO BUILDING PERMIT FEES Account # Type Cost 01-44221 Building Permit 01-44223 Mechanical 01-44224 Plumbing 01-44225 Electrical 01-44221 Mobile Home Permit 01-44222 Grading Permit Fee 01-44231 Grading Plan Check 01-44222 On-Site Residential Permit 01-44231 On-Site Residential Plan Check Subtotal 01-44230 Bond Processing 01-44230 Building Plan Check 01-44230 Additional Plan Check 01-44230 Digital Record Fee ($1.00 per sheet) 01-44221 C & D Administrative Fee 01-44221 Special Inspection-Reinspection 01-44222 On-Site Commercial/Tract Permit Fee 01-44231 On-Site Commercial/Tract Plan Check Fee 01-44214 Geotechnical Soils Plan Review 10-44320 Ordinance 211 10-42510 Ordinance 364 01-45354 Copies @ .20 Each 90-23331 SMIP Fee 33-44370 H.O.P.E. Fee (Housing in Lieu) Other Fees TCA Fees Date Received HOA Approval Date Received School Fees Date Received Engineering Fees Date Received Water Division Fees Date Received 01-44221 01-44221 01-44240 90-23000 90-23000 TOTAL FEES PAYABLE TO CITY OF SAN JUAN CAPISTRANO Receipt # _________ Date: ______________ Cashier: _____________________________ Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type Title 24 Energy Provision (20% Permit Subtotal & Bldg Plan Check)) Title 24 ADA Fee (10% Permit Subtotal & Bldg Plan Check) Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type NPDES Permit Fee (10% Permit Subtotal) $0.00 $ 61.02 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $6.10 $ 39.90 8/31/2023 $ 107.02 $0.00 $ 61.02 8/31/2023 B23-0525 BETTER EARTH ELECTRIC INC 33562 VIA DE AGUA 95804 (323) 523-7379 $0.00 33562 via de agua, San Juan Capistrano, CA 92675V-BR-3/U2ROOF MOUNTED PV SYSTEM SIZE OF 10.44 KWP, 29 MODULE/PANELS OPTIMIZERS, 1 INVERTER MAIN PANEL UPGRADE 225A/200A 19,523MARIA OROZCO323 523-7379MARIA.O@BETTEREARTH.SOLAR1024460BETTER EARTH ELECTRIC16720 MARQUARDT AVECERRITOS,CA 90703HEATHER TAYLOR33562 via de agua San Juan Capistrano, CA 926751MARIA OROZCO3/30/20232590B23 05257.60 kW ACNO BBU5125A1 GENERAL REQUIREMENTS 1.System size is 10 kW AC CEC rating or less Y N 2.Solar array is roof mounted on a one or two family dwelling Y N 3.Solar panels/module arrays will not exceed the maximum legal building height Y N 4.Solar system is utility interactive and without battery storage Y N 5.Permit application is completed and attached Y N ELECTRICAL REQUIREMENTS 1.No more than four (4) photovoltaic module strings are connected to each Maximum Power Point Tracking (MPPT) input where source circuit fusing is included in the inverter Y N a.No more than two (2) strings per MPPT input where source circuit fusing is not included Y N b.Fuses (if needed) are rated to the series fuse rating of the PV module Y N c.No more than one (1) non-inverter-integrated DC combiner is utilized per inverter Y N 2.For central inverter systems – No more than two (2) inverters are utilized Y N 3.The PV system is interconnected to a single-phase AC service panel of nominal 120/220 Vac with a bus bar rating of 225A or less Y N 4.The PV system is connected to the load side of the utility distribution equipment**Y N 5.A Solar PV Standard Plan and supporting documentation is completed and attached Y N STRUCTURAL REQUIREMENTS 1.A completed Structural Criteria and supporting documentation is attached and stamped by a licensed design professional Y N RESIDENTIAL PHOTOVOLTAIC ELIGIBILITY CHECKLIST Solar Photovoltaic (PV) Checklist for Detached One- or Two- Family Dwellings Instructions: The licensed contractor of record shall fill in the address of the project, contractor’s licensing information and answer each statement with Y or N. Complete and sign the certification section. ** If any items are checked NO, plan check shall be required ** Project Address: ___________________________________________________ Contractor Company Name: ____________________________________________________ Contractor State License Number: ____________________________________________________ City of SJC Business License Number: _________________________________ City of San Juan Capistrano DeDevelopment Services Department 32400 Paseo Adelanto San Juan Capistrano, CA 92675 Phone: (949) 443-6347 Email: building@sanjuancapistrano.org www.sanjuancapistrano.org/building FIRE SAFETY REQUIREMENTS 1.Clear access pathways provided per OCFA guidelines Y N 2.Fire classification solar system is provided (Class A)Y N 3.All required markings and labels are provided Y N 4.Diagram of the roof layout of all panels, modules, clear access pathways and approximate locations of electrical disconnecting means and roof access points is completed and attached Y N CITY SPECIFIC REQUIREMENTS Y N Y N Y N Y N Y N Y N Y N 1.Permit Application (Completed & Attached) 2.Signed contract with the homeowner is provided with submittal 3.A load calculation is provided for all sub-panel installations and/or downsized main breakers 4.A load calculation AND panel schedule is provided for all Center Fed Main Panels 5.An SDG&E Work Order is provided for all Main Panel upgrades 6.A load calculation AND panel schedule is provided for all Main Panel upgrades 7.Manufacturers Specifications are provided for ALL electrical components that will be installed **Renewable Meter Adapter (RMA) installations must be approved by SDG&E and have a separate GEC. Any and all grounding work not performed by SDG&E, including but not limited to the RMA disconnect, will be performed by the Solar Contractor. I certify under penalty of perjury under the laws of the State of California that the above is true and correct. I understand that all approvals are subject to field inspection. Field corrections may require a formal revision submitted for plan review. A re-inspection fee may be assessed when work is not ready, inspection card and/or approved plans are not available, no access has been provided or there is any deviation from the approved plans.: Print Name: ____________________________________________ Date: ___________________ Signature: __________________________________________________________________________________ Phone Number: ___________________________________ Email Address: ______________________________________________________________________________ Additional Address Info: PROCEDURE FOR INSTALLATION 1. PHONE DIG ALERT "811" AT LEAST TWO DAYS PRIOR TO TRENCHING FOR LOCATION OF UNDERGROUND UTILITIES. 2. Phone Operations Assistant at 949-361-8066 for the following: - 3 Working days prior to trenching to arrange pre-meet with inspector and initiate trenching process. - After excavation of trench, installation of conduit and service entrance equipment at meter location, CALL FOR INSPECTION. Do not cover conduit without inspector's written approval to backfill. - When trench is backfilled and compacted, CALL FOR INSPECTION. - If service entrance equipment is installed after backfill, CALL FOR INSPECTION OF THE EQUIPMENT. 3. Meter cannot be set until inspector has approved installation, including service equipment, and receipt of city/county/state inspection Metering: Self-Contained Meter Clips: 4 Utilities Maximum Contribution to Fault Current: 10,000Phase: 1# of Wires: 3 Voltage: 120/240 Bend Info: Bend Type: Riser Quad: Stop Trench: from PoleLadder Arms: Standards Page: Handhole Lid Shall Read: Structure #: UNMAPPED SHStation ID #: 795-264 Temp Service Charge due on First Bill $ 0.00 Assessor's Parcel Number:Additional Information: To minimize the electrical outage, you are advised to schedule a morning disconnect with an afternoon reconnect. There is no charge for this service. Before you change out your meter consider (1) SDG&E needs advance notice to schedule a crew and (2) SDG&E will not reconnect the service without municipal approval on the new panel. Please contact the City of San Juan Capistrano regarding permits and inspections. City/County inspection should be received prior to 2:00 p.m. on the same day as the disconnection of service to allow the SDG&E crew enough time for reconnection of the service on the same day. Number/Size of Main Switch: 1/125Service Panel Rating: 125 Conduit Size: Conduit Installed By: Customer Phone #: 661-268-2820Customer POC: Isabel Aguilar Wanted Date: ON CITY INSP. Job #: 530000326387 ELECTRIC UNDERGROUND METER & SERVICE LOCATION Customer Copy Project Title: SOT OC 33562 VIA DE AGUA SJ DR US SOLAR Notification #: 300000587610 Project Address: 33562 VIA DE AGUA Customer Type: Residential(>2 Units) Date Prepared: 07/25/2023 Project City: SAN JUAN CAPISTRANO SDGE Contact: Operations Assistant Contact Info: SERVICE DESK,949-361-8066 Service Type: UG REWIRE (NO TRENCHING) TB: 0972-D5 SERVICE ATTACHMENT POINT AND/OR METER LOCATION: Customer to install 125A meter panel at existing location over existing conduit & service conductors. Position new panel to maintain 3x3 clear & level working space as shown on SDGE Spec 507. Customer to install new panel to meet the location of existing landing lungs. No splicing allowed. The existing conduit & conductors are adequate for a maximum 125A main or less - if customer installs greater than a 125A main or installs the panel otherwise, customer will be required to trench from the meter panel to the source & install the required 3 inch DB conduit. See SDGE Service and Standards Guide pages for specifications. To schedule, call Service Desk number listed above. Solar System Questions - www.SDGE.com/NEM - SDGE Net Energy Metering Team SDG&E Application Required-Call: 1-800-411-7343 Municipal Inspection required By: CITY OF SAN JUAN CAPISTRANO Bend Installed By: Handhole Installed By: Traffic Control Permit Required Excavation/Encroachment Permits Required By: Joint Trench With: Right of Way Required Meter height -- 4'0'' min. (3'0" min. for multiple installation) -- 6'3" max. From finish grade to centerline of meter base. Meters are required to be readily accessible 24 hours per day. Meters must be located in a safe area free of any potentially hazardous or dangerous condition. Provide 3-ft. x 3-ft. clear and level working space in front of meter. Where meter room is proposed, contact the planner at the nearest SDG&E office. Meter bases and meter service disconnects must be located at or immediately adjacent to each other and be identified with address and unit number. If SDG&E encounters hazardous or toxic material while performing construction of your project, SDG&E will halt work immediately and it will be your responsibility to remove and or clean up all hazardous or toxic material prior to SDG&E continuing construction. SDG&E shall have no liability or obligation whatsoever to cleanup, remove or remediate any hazardous or toxic materials discovered during the course of construction unless it is through negligence of SDG&E. Customer-owned facilities to receive gas service are subject to all applicable local and state of California inspection authority requirements. Building address and/or houseline must be permanently identified prior to meter set. Barrier posts may be required based on field conditions at any time prior to meter set as determined by the SDG&E Representative. Per Rule 16.A.1.a. In compliance with Section 783 of the Public Utilities Code, SDG&E will apply only those construction and design specifications, standards, terms, and conditions that are applicable to a new extension of service project for the 18 months following the date the application for a new extension of service project is approved. Keep this notice with your building permit. All installations performed under this order must meet SDG&E standards unless a written deviation has been approved. Planned By: Elice Harris Phone#: 6196766059 DIANNA F.08/29/23B23-0525SUBJECT TO FIELD INSPECTION WĂŐĞϮͬϯ Check All Applicable Description of Load Volt-Amps on Nameplate Rating (Watts) Volt-Amps Used General Lighting/Power Load ZĞƋƵŝƌĞĚ Total Square footage of building times 3 sf džϯǀŽůƚͲĂŵƉ ZĞƋƵŝƌĞĚ Kitchen Small Appliance Branch Circuits (min. 2) 1,500 volt-amps/circuit ZĞƋƵŝƌĞĚ Laundry Circuit (min. 1) 1,500 Volt-Amps Appliances and Equipment Except Air Conditioner(s) Microwave 1,400 watts Trash Compactor 1,000 watts Dishwasher 1,500 watts Disposal 1,000 watts Electric Oven 2,000 watts Electric Range 5,000 watts Induction Range 10,000 watts Electric Clothes Dryer 4,000 watts Electric Clothes Washer 500 watts Electric Tankless Water Heater 15,000 watts Electric Water Heater 4,000 watts Electric Heat Pump Water Heater 550 watts Required on new homes Electric Vehicle Supply Equipment (EVSE) 7,000 watts Evaporative Cooler 500 watts Pool or Spa 2,000 watts Other: Other: Other: Sub-Total Volt-Amps Used (add up V-A used for everything checked) Ͳ ϭϬ͕ϬϬϬsͲ Subtotal (A) x .40 Subtotal (B) н ϭϬ͕ϬϬϬsͲ Subtotal (C) Heating and Air-Conditioning (ĚĚ the largest of the following): н 1. Air conditioning and cooling (100% of nameplate (NP) rating) = 2. Heat pump without supplemental heating (100% NP Rating) = 3. Heat pump with supplemental electric heat (100% NP plus 65%) = 4. Electrical space heating , 4 separate units (65% NP rating) = 5. Electrical space heating > 4 separate units (40% NP rating) = 6. Electrical thermal storage and other 100% NP rating = Total Current Demand (Volt-Amps) = Divided by 240 Volts = Amps Total Amps Required for Service Conductors and Panel = Rating of Existing Electrical Service or Subpanel (Amps)= Panel Upgrade Required?;z^KZEKͿ Rating of WƌŽƉŽƐĞĚ Electrical Service or Subpanel (/&z^Ks)= watts watts watts &ϬϳͬϭϵͬϮϯ 7,200 3,000 1,500 1,920 1,920 1,920 9,600 5,000 11,520 43,580 33,580 13,432 23,432 23,432 100 Yes 98 ✔ ✔ ✔ ✔ ✔ ✔ 2,400 98 125 Digitally sealed by RJM on Date: Job #: 3/28/23 Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Taylor Residence 33562 Via de Agua San Juan Capistrano, CA 92675 3/28/23 Designed in Accordance with CBC 2022, ASCE 7-16 23-05896 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave Jurupa Valley, CA 92509 Mobile: (909) 566-0066 Email: SE@mcpe.group 3/28/2023 2:16 PM 1 of 7 ©McPherson Engineering McPherson Engineering By:T.C. Date:3/28/23 Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 Table Of Contents *Note: This engineering report is limited to the information presented to Engineer via plans, site information, photos, and written correspondence as provided by Client. On-site structural observations and verification of site conditions are not included herein. Engineering for manufactured products such as photovoltaic modules or racking systems is excluded from this report. Please refer to the manufacturer's specifications, certifications, and pre-engineered packages for product engineering. Installations of solar modules and related equipment must be performed in accordance with manufacturer recommendations, local codes, local regulations, industry best practices, and applicable safety standards. Owner and/or Contractor shall notify Engineer should any damage, deterioration, or descrepancies between current condition of the structure or otherwise as this letter describes before proceding with construction. This letter applies only to regions of the structure where solar modules will be supported and the supporting elements. 3/28/2023 2:16 PM 2 of 7 ©McPherson Engineering McPherson Engineering By:T.C. Date:3/28/23 Location: 33562 Via de Agua San Juan Capistrano, CA 92675 Existing Structure Info: Number of Stories =2 Aroof =2590 sq. ft.Roof Square Footage A3rd_flr =0 sq. ft.Third Floor Square Footage (if applicable) A2nd_flr =1500 sq. ft.Second Floor Square Footage (if applicable) Site Properties: Lattitude = Longitude = Ss = 1.182 S1 = 0.426 Exposure Category =C Ult. Wind Speed =130 m.p.h. P.V. Array Info: Model =HANWHA Q.PEAK DUO BLK-G10+/AC 360W Height of Panel =67.60 in. Width of Panel =41.10 in. Area of Panel = 19.3 ft.2 Number of New Panels =29 Number of Exis. Panels =0 Total Area of Array = 559.5 ft.2 Spacing of Anchors =4.0 ft. max. on center rows of racks per panel =2 Panel Tilt =7-27 deg Project Info 33.475696 -117.658519 3/28/2023 2:16 PM 3 of 7 ©McPherson Engineering McPherson Engineering By:T.C. Date:3/28/23 Existing Loads: Roof Design Loads: Roofing = 10.0 p.s.f.Concrete Tile roofing Sheathing =1.5 p.s.f.1/2" Plywood Framing =1.5 p.s.f.2x Framing Misc =1.0 p.s.f. DLr1 =14.0 p.s.f. Roofing Dead Load (applied to top of rafters/trusses only) Ceiling =2.0 p.s.f.Drywall and framing DLr2 =16.0 p.s.f.Total Existing Roof Dead Load LLr = 20.0 p.s.f.Roof Live Load (Per C.B.C, Table 1607.1) SL = 0.0 p.s.f.Snow Load Floor Design Loads: (if applicable) Flooring =10.0 p.s.f.Weight of floor finish Sheathing = 2.2 p.s.f.3/4" plywood Framing =2.0 p.s.f.2x framing or manufactured floor truss Interior Partitions =15.0 p.s.f.2x framed walls with drywall finish each side Ceiling =5.0 p.s.f.Drywall ceiling finish below Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f.Total Existing Floor Dead Load Proposed Loads: Panels =2.9 p.s.f.weight of panels including rack system DLr1_proposed =16.9 p.s.f.Proposed Roof Dead Load (applied to top only) DLr2_proposed =18.9 p.s.f.Total Proposed Roof Dead Load LLr_proposed = 0.0 p.s.f. Check Proposed Gravity Loads: Total Existing Roof Load Wex = (DLr1 + LLr) (Aroof) =88.1 kips Total Proposed Roof Load Wprop = (DLr1 + LLr) (Aroof - Aarray) + (DLr1_proposed + LLr_proposed) (Aarray) =78.5 kips Proposed Load Demand Gravity Loads Roof Live Loads need not be applied to the area covered with by PV panel where the clear space between the panels and the roof sureface is 24in or less, 1607.13.5.1 item 1 Exception Wprop - Wex =-10.87% TOTAL DECREASE IN GRAVITY LOADS, PANELS OK! Wex 3/28/2023 2:16 PM 4 of 7 ©McPherson Engineering McPherson Engineering By:T.C. Date:3/28/23 Seismic Design Parameters Risk Category =2 Per Table 1-5-1 R =6.5 Response Modification Factor (Table 12-2.1) Site Class = D Per 11.4.2 Ie =1 Seismic Importance Factor (Table 1.5-2) Ss =1.18 Short Period P.G.A. S1 =0.43 1-Sec Period P.G.A. S.D.C. =D Seismic Design Category Per 11.6 Fa =1.20 Site Coefficient per Table 11.4-1 ASCE 7-16 Supplement #1 Tables used for Fa and Fv Fv =1.70 Site Coefficient per Table 11.4-2 (note: section 11.4.8 Exception #2 calc used) SMS = SDS Fa =1.42 Short Period M.C.E. Per Eq. 11.4-1 SM1 = SD1 Fv =0.72 1-Sec Period M.C.E. Per Eq. 11.4-2 SDS = 2/3 (SMS) =0.95 Short Period Design Parameter Per Eq 11.4-3 SD1 = 2/3 (SM1) =0.48 1-Sec Period Design Parameter Per Eq 11.4-4 Approximate Fundamental Period (Per 12.8.2.1) per Eq. 12.8-7 hn = 20 ft Ct =0.02 (per table 12.8-2) x = 0.75 (per table 12.8-2) T =0.19 sec Approximate Fundamental Period TL =8 sec Long-Period Transition Period per Figure 22-12 Seismic Response Coefficient (Per 12.8.1.1) CS = (SDS Ie)/R = 0.15 Seismic Response Coefficient Per Eq. 12.8-2 Cs1 = 1.5*(SD1 Ie)/R T = 0.59 Max. Seismic Response Coefficient Per Eq. 12.8-3 if T ≤ TL Cs2 =0.01 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs2 = 0.044 SDS Ie =0.04 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs3 = 0.5 S1 Ie/R =0.03 Min. Seismic Response Coefficient Per Eq. 12.8-6 if S 1 ≥ 0.6g CS =0.15 Design Seismic Coefficient Check Additional Base Shear Wexisting =93.9 kips Weight of Existing Structure Wpanels =1.6 kips Weight of Proposed Panels Vexisting = Cs Wexisting =13.7 kips Roof Level Shear of Existing Structure Vpanels = Cs W panels =0.2 kips Additional Roof Level Shear of Proposed Panels Vpanels Vexisting Lateral Loads T = Ct (hn)x = 1.73% < 10% PER C.E.B.C. 502.5 EXCEPTION, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 3/28/2023 2:16 PM 5 of 7 ©McPherson Engineering McPherson Engineering By:T.C. Date:3/28/23 Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7-16) Vult =130 mph Kzt =1.00 (sec 26.8.2)h = 20 ft Exposure Category = C Kz = 0.90 (sec 26.10.1) Roof Zone = 2 Kd =0.85 (sec 26.6) Roof θ = 7-27 deg Ke =1.00 (sec 26.9) qh = 0.00256 Kz Kzt Kd Ke V2 qh =33.10 (eq. 26.10-1) GPp =-2 uplift γE =1.5 (sec 29.4.4) γa =0.78 (fig 29.4-8) γE =1.5 FIG 29.4-7)γc =0.94 (fig 29.4-7)hpt =0 γa =0.78 (fig 29.4-8)γp =0.9 (fig 29.4-7)ω =0.00 deg (panel tilt) GPp =-2 uplift GCrm =1.4 uplift p = qh (GPp) γE γa (eq 29.4-7)p = qh (GCrn) γE γC γp (eq 29.4-6) p =-77.4 p.s.f.p =58.7 p.s.f. Check Anchorage to Existing Structure 0.6DL - 0.6W controlling load combination (eq. 16-15 for ASD) DL =2.9 p.s.f.dead load of panel (inlcuding rack system) W = 77.4 p.s.f.wind load normal to face of panel Arealag =11.3 sq. ft.area tributary to each anchor SPanc =4.0 ft.spacing of anchors Puplift = Arealag (0.6DL - 0.6W) =503.5 lbs total uplift on anchor Material =DFL lumber anchor material Dialag =5/16 in.diameter of screw Penlag =2.5 in.min. penetration to existing framing W lag =266 lb/in.withdrawal load per in. of penetration per NDS Table 11.2A CD =1.6 load duration factor for wind per NDS Table 2.3.2 Ct =0.8 temperature factor per NDS Table 2.3.3 Noscrews =2 number of screws in withdrawal Pallow = Penlag (Wlag CD Ct) * Noscrews =1702.4 lbs total allowable withrawal on anchor Puplift Pallow Anchorage =USE (2) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Wind Uplift Anchorage Flush Mounted Panels - ASCE Section 29.4.4 (where applicable) Flat Roof Panels - ASCE Section 29.4.3 (where applicable) =0.30 < 1.00 Anchor is OK! 3/28/2023 2:16 PM 6 of 7 ©McPherson Engineering McPherson Engineering By:T.C. Date:3/28/23 Gravity Loads: DEMAND DECREASED BY 10.87% = OK! Lateral Loads: DEMAND INCREASED BY 1.73% < 10% = OK! Anchorage: DEMAND OF 503.5LB. < CAPACITY OF 1702.4LB. = OK! USE (2) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Summary: STRUCTURE IS ADEQUATE FOR THE PROPOSED PV ARRAY ANCHORS ON EAVES/OVERHANGS ARE OK! Summary 3/28/2023 2:16 PM 7 of 7 ©McPherson Engineering