B23-1264 - 27911 PASEO NICOLECITY OF SAN JUAN CAPISTRANO
BUILDING PERMIT
Permit No. B23-1264
04/23/2024
ISSUED
JOB VALUE
NO UNITS
Permit Number
ISSUED BY
SITE APN
SITE LOT NO
SITE TRACT
SITE SUBDIVISION
PERMIT TYPE.
OCCUPANCY TYPE
BUILDING SF
NO STORIES
DF4
666-082-16
26
$ 17,000
SOLAR PANEL INSTALLA
0
1
0
JOB ADDRESS: 27911 PASEO NICOLE
KALLEN, CHARLIEOWNER NAME
27911 PASEO NICOLEMAILING ADDRESS
CITY,STATE,ZIP
CONTRACTOR NAME
ST. LIC EXPIRE
ADDRESS
CITY, ST, ZIP
TENANT NAME
PHONE #
MAILING ADDR
CITY, ST, ZIP
I have carefully examined the completed permit application and do hereby certify under penalty of
perjury that all information hereon including the declarations are true and correct and I further
certify and agree if a permit is issued: to comply with all City, County, and State laws governing
building construction, whether specified herein or not. I also agree to save, indemnify and keep
harmless the City of San Juan Capistrano against all liabilities, judgments, costs and expenses
which may in any way accrue against said City in consequence of the granting of this permit.
Applicant's signature
Owner/Contractor
Print Name
INDIGO SOLAR
26820 CRILLY RD
02/29/2024
AMOUNT
MECHANICAL PERMIT AMOUNT
Expiration:: Every permit issued shall become invalid unless the work on the site authorized by
such permit is commenced within 12 months after its issuance, or if the work authorized on the
site by such permit is suspended or abandoned for a period of 12 mounths after the time the
work commenced.
An OSHA permit is required for excavations over 5’0” deep and demolition or construction of
structures over 3 stories in height.
_____Contractor:I hereby affirm that I am licensed under provisions of Chapter 9 of Division 3 of the Business and Professions Code, and my license is in full force and effect.
_____Owner/Builder:I, as owner of the property, or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale. (Sec.7044, Business and Professions
Code: the Contractor’s License Laws does not apply to and owner of property who builds or improves thereon, who does such work himself or through his employees, provided that such improvements are not
intended or offered for sale. If however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
______Owner/Builder:I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor’s License Law does not
apply to an owner of property who builds or improves thereon and who contracts for such projects with a contractor’s) license pursuant to the Contractor’s License Law.
_______ Workers Compensation-I hereby affirm under penalty of perjury one of the following declarations:I have and will maintain workers’ compensation insurance, as required by Section 3700 of the
Labor Code, for the performance of the work for which this permit is issued. My workers’ compensation insurance carrier and policy number are: Carrier__EXEMPT Policy# (This section needs to be
completed if the permit is for one hundred dollars($100) or less)
AMOUNTELECTRICAL PERMIT
DESCRIPTION
_______Exemption:I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers’ compensation laws of
California and agree that if I should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions.
WARNING:FAILURE TO SECURE WORKERS’COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TI CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED
THOUSDAND DOLLARS($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
B23-1264
Total Electrical
Total Plumbing
Total Mechanical
Total Mobile Home
1086834
,
CORONA, CA 92883
SAN JUAN CAPISTRANO, CA 92675
(949) 212-6182
(951) 427-4527
PHONE
PHONE
Date _________________ Applicant _______________________________________
MOBILE HOME PERMIT AMOUNT
14 ROOF MOUNTED SOLAR PANELS. 5.044kW AC SYSTEM.
PLUMBING PERMIT
CARLOS ARVIZU
4/23/2024
CA
FINAL
06/10/24
Date:
Permit No.
Applicant:
Phone/E-Mail
Job Location:
CITY OF SAN JUAN CAPISTRANO
BUILDING PERMIT FEES
Account # Type Cost
01-44221 Building Permit
01-44223 Mechanical
01-44224 Plumbing
01-44225 Electrical
01-44221 Mobile Home Permit
01-44222 Grading Permit Fee
01-44231 Grading Plan Check
01-44222 On-Site Residential Permit
01-44231 On-Site Residential Plan Check
Subtotal
01-44230 Bond Processing
01-44230 Building Plan Check
01-44230 Additional Plan Check
01-44230 Digital Record Fee ($1.00 per sheet)
01-44221 C & D Administrative Fee
01-44221 Special Inspection-Reinspection
01-44222 On-Site Commercial/Tract Permit Fee
01-44231 On-Site Commercial/Tract Plan Check Fee
01-44214 Geotechnical Soils Plan Review
10-44320 Ordinance 211
10-42510 Ordinance 364
01-45354 Copies @ .20 Each
90-23331 SMIP Fee
33-44370 H.O.P.E. Fee (Housing in Lieu)
Other Fees
TCA Fees Date Received
HOA Approval Date Received
School Fees Date Received
Engineering Fees Date Received
Water Division Fees Date Received
01-44221
01-44221
01-44240
90-23000
90-23000
TOTAL FEES PAYABLE TO CITY OF SAN JUAN CAPISTRANO
Receipt # ______________ Date: ______________ Cashier: _____________________________
Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type
Title 24 Energy Provision (20% Permit Subtotal & Bldg Plan Check))
Title 24 ADA Fee (10% Permit Subtotal & Bldg Plan Check)
Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type
NPDES Permit Fee (10% Permit Subtotal)
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
4/23/2024
$0.00
$0.00
$0.00
4/23/2024
B23-1264
INDIGO SOLAR
27911 PASEO NICOLE
(951) 427-4527
$0.00
-
Name
Address
City/State/Zip
TENANT NAME
Phone ( )
ACCESSORY DWELLING UNIT
QTY QTY QTY QTY
Light Fixtures/Fans
FAU < 100k BTU's
Fixtures/Hose Bibs
New/Setup
Outlets/Switches FAU > 100k BTU's
Water Heater
Carport
Meters/Main Panels
AC/Comp BTU=
Water Piping
Gas Systems
Awning
Signs
Exhaust Fans
Temp Power
Motors > than 1 HP
Motors < than 1 HP
Duct/Register/Grill
Pool/Spa
Pool/Spa
Extend Plumbing
APPLICANT SIGNATURE DATE
Porch
ISSUANCE
ELECTRICAL PLUMBINGMECHANICAL
ISSUANCEISSUANCE
Fireplace
ISSUANCE
Fire Sprinkler Heads
Miscellaneous
PROPERTY OWNER
Appliance Vent
CONSTRUCTION TYPE NO. OF STORIES
MOBILE HOME
PROJECT ADDRESS UNIT #:
Extend Electrical
Cabana
OCCUPANCY GROUP(S)
SPRINKLERS
PERMIT NUMBER
JOB VALUATION
Pool/Spa
Vent/Exhaust Hood
Miscellaneous
Grease Interceptor
Earthquake Bracing
Electrical Wiring
Gas Piping
Sewage Disposal
Water Piping
City of San Juan Capistrano
DeDevelopment Services Department
32400 Paseo Adelanto
SaSan Juan Capistrano, CA 92675
Phone: (949) 443-6347
Email:building@sanjuancapistrano.org
www.sanjuancapistrano.org/building
Building Sewer
ATTACHED DETACHED
NEW
CONSTRUCTION
CONVERSION OF
EXISTING STRUCTURE
JADU 1.
2.
OCCUPANCY CURRENT OCCUPANCY PROPOSED
INT. ALT.
ADDITION
PATIO
POOL/SPA
DEMOLITION
EXISTING BUILDING ____SQ.FT.____SQ.FT.____SQ.FT.____SQ.FT.____SQ.FT.
NEW BUILDING
____SQ.FT.____SQ.FT.____SQ.FT.____SQ.FT.
________________
OCC. GROUP
DESCRIPTION OF WORK
COMBINING OR SUBDIVIDING SUITES?
CHANGE OF OCCUPANCY USE?
YES NO
YES NO
YES NO
APPLICANT
CONTACT NAME
CONTACT PHONE ( )
EMAIL ADDRESS
$
PRINT NAME
As the applicant for this project, I am aware of the potential liabilities with undertaking construction within any private easement or use restriction area that may exist on this property. I acknowledge that I have or will review the Title Report for this property to ensure that this project does not impact any private easements or use restriction areas. By signing below, I CERTIFY THE ABOVE INFORMATION TO BE TRUE AND CORRECT.
CONTRACTOR State License #:
Name
Address
City/State/Zip
BUILDING PERMIT APPLICATION
LL 06/28/23
WARNING:
THIS PERMIT APPLICATION WILL EXPIRE 180 DAYS FROM
THE DATE SHOWN BELOW UNLESS THE PERMIT HAS BEEN
ISSUED OR AN EXTENSION IS APPROVED BY THE BUILDING
OFFICAL PRIOR TO APPLICATION EXPIRATION.
____/____/____
:
27911 PASEO NICOLE, SAN JUAN CAPISTRANO, CA 92675
17,000
SYSTEM SIZE: 5.46kW DC, 5.044kW CEC-AC
MODULES: (14) JA SOLAR JAM54S31-390/MR
INVERTER: (1) SOLAREDGE SE3800H-US [240V]
OPTIMIZERS: (14) SOLAREDGE P400
RACKING: IRONRIDGE
ROOF TYPE: COMP SHINGLE
09 11 23
B23 1264
NO MPU/BBU
GENERAL REQUIREMENTS
Y N
Y N
Y N
Y N
1.System size is 10 kW rating or less
2.Solar array is roof mounted on a one or two family dwelling OR accessory dwelling unit (ADU)
3.Solar panels/module arrays will not exceed the maximum legal building height
4.Solar system is utility interactive and without battery storage
5. New roofing material directly below the solar array may be installed by a separate roofing contractor
or the solar installation contractor. Any roofing outside of the array footprint will require a separate
permit from a licensed roofing contractor.
RESIDENTIAL PHOTOVOLTAIC
ELIGIBILITY CHECKLIST
Solar Photovoltaic (PV) Checklist for
Detached One- or Two- Family Dwellings
Instructions: The licensed contractor of record shall fill in the address of the project, contractor’s licensing
information and answer each statement with Y or N. Complete and sign the certification section.
** If any items are checked NO, plan check shall be required **
Project Address: ___________________________________________________
Contractor Company Name: ____________________________________________________
Contractor State License Number: ____________________________________________________
City of SJC Business License Number: _________________________________
City of San Juan Capistrano
DeDevelopment Services Department
32400 Paseo Adelanto
San Juan Capistrano, CA 92675
Phone: (949) 443-6347
Email: building@sanjuancapistrano.org
www.sanjuancapistrano.org/building
07/03/23 LL
1.Permit Application (Completed & Attached)
2.Signed Contract or letter of intent with the homeowner is provided with submittal
3.Structural Roof Criteria and supporting documentation is attached and stamped by a licensed design
professional
4.Electrical load calculation is required for all installations. (MUST BE COMPLETED ON CITY STANDARD
TEMPLATE)
5.SDG&E Work Order is required for all Main Panel Upgrades
6.Clear photographs required of existing main service panel and subpanels showing ALL circuit breakers/
loads and panel board/bus ratings.
7.Manufacturers Specifications required for ALL electrical components that will be installed
Y N
Y N
Y N
Y N
Y N
Y N
Y N
STRUCTURAL REQUIREMENTS
1.A completed Structural Criteria and supporting documentation is attached and stamped by a licensed
design professional for solar array attachment and/or any separate structure or racking supporting array
or equipment.
Y N
Y N
CITY SPECIFIC REQUIREMENTS
FIRE SAFETY REQUIREMENTS
1.Clear access pathways provided per OCFA and CRC guidelines
2.Fire classification solar system is provided (Class A)
3.All required markings and labels are provided
4.Diagram of the roof layout of all panels, modules, clear access pathways and approximate
locations of electrical disconnecting means and roof access points is completed and
attached
**Renewable Meter Adapter (RMA) installations must be approved by SDG&E and have a separate GEC. Any and all grounding work not performed by SDG&E, including but not limited to the RMA disconnect, will be performed by the Solar Contractor.
I certify under penalty of perjury under the laws of the State of California that the above is true and
correct. I understand that all approvals are subject to field inspection. Field corrections may
require a formal revision submitted for plan review. A re-inspection fee may be assessed when
work is not ready, inspection card and/or approved plans are not available, no access has been
provided or there is any deviation from the approved plans.:
Print Name: ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ Date: ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ
Signature: ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ
Phone Number:ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ
Email Address: ͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺͺ
ELECTRICAL REQUIREMENTS
1.The PV system is interconnected to a single-phase AC service panel of nominal 120/220 Vac with
a bus bar rating of 225A or greater
2.The PV system is connected to the load side of the utility distribution equipment**
3.A Solar PV Standard Plan and supporting documentation is completed and attached
Y N
Y N
Y N
Y N
Y N
Y N
Y N
RESIDENTIAL ELECTRICAL
LOAD A
Review the electrical loads in the table below and check all that exist in the home
(be sure to include the proposed Level 2 EVCE and/or Photovoltaic System). Fill in the corresponding
wattage for each item checked, and then add up all the checked items to determine total wattage used.
Wattages shown are rough estimates: for a more precise analysis use actual values based on nameplate
ratings or consult with an electrical professional.
_______________________________________________________________________________
STATEMENT OF COMPLIANCE:
By my signature, I attest that the information provided is true and accurate.
_________________________________________________________________
(Print Name)
__________________________________ __________
(Signature of Applicant) (Date)
Note: This form is a voluntary compliance alternative and you may wish to hire a qualified individual or
company to perform a thorough evaluation of your electrical service capacity in lieu of this
methodology. Use of this electrical load calculation worksheet is at the user’s risk and carries no implied
guarantee of accuracy. Users of this form are advised to seek professional assistance in determining the
electrical capacity of a service panel.
CITY OF SAN JUAN CAPISTRANO
CBC/CRC 105.4.shall not
be construed of any
of the provisions of the applicable code or of any other ordinance
of the violate or
cancel provisions of the applicable code or other ordinances of the
jurisdiction based on
construction prevent the
building in the
construction Every EverEver
permit authorized by
such permit is commenced within 12 months after its issuance, or if
the work abandoned for
a period of 12 months after the time the
APPROVED B TE: ______________
PERMIT #: _______________________ ______________
COMMENTS: __________________________________________COMMENTS: __________________________________________COMMENTS: ____________________________________________
WĂŐĞϮͬϯ
Check All
Applicable
Description of Load Volt-Amps on
Nameplate Rating
(Watts) Volt-Amps
Used
General Lighting/Power Load
ZĞƋƵŝƌĞĚ Total Square footage of building times 3 sf džϯǀŽůƚͲĂŵƉ
ZĞƋƵŝƌĞĚ Kitchen Small Appliance Branch Circuits
(min. 2)
1,500 volt-amps/circuit
ZĞƋƵŝƌĞĚ Laundry Circuit (min. 1) 1,500 Volt-Amps
Appliances and Equipment Except Air Conditioner(s)
Microwave 1,400 watts
Trash Compactor 1,000 watts
Dishwasher 1,500 watts
Disposal 1,000 watts
Electric Oven 2,000 watts
Electric Range 5,000 watts
Induction Range 10,000 watts
Electric Clothes Dryer 4,000 watts
Electric Clothes Washer 500 watts
Electric Tankless Water Heater 15,000 watts
Electric Water Heater 4,000 watts
Electric Heat Pump Water Heater 550 watts
Required on new
homes
Electric Vehicle Supply Equipment (EVSE) 7,000 watts
Evaporative Cooler 500 watts
Pool or Spa 2,000 watts
Other:
Other:
Other:
Sub-Total Volt-Amps Used (add up V-A used for everything checked)
Ͳ ϭϬ͕ϬϬϬsͲ
Subtotal (A)
x .40
Subtotal (B)
н ϭϬ͕ϬϬϬsͲ
Subtotal (C)
Heating and Air-Conditioning (ĚĚ the largest of the following): н
1. Air conditioning and cooling (100% of nameplate (NP) rating) =
2. Heat pump without supplemental heating (100% NP Rating) =
3. Heat pump with supplemental electric heat (100% NP plus 65%) =
4. Electrical space heating , 4 separate units (65% NP rating) =
5. Electrical space heating > 4 separate units (40% NP rating) =
6. Electrical thermal storage and other 100% NP rating =
Total Current Demand (Volt-Amps) =
Divided by 240 Volts = Amps
Total Amps Required for Service Conductors and Panel =
Rating of Existing Electrical Service or Subpanel (Amps)=
Panel Upgrade Required?;z^KZEKͿ
Rating of WƌŽƉŽƐĞĚ Electrical Service or Subpanel (/&z^Ks)=
watts
watts
watts
>>ϬϱͬϭϱͬϮϯ
4,638
3,000
1,500
1,400
1,500
1,000
2,000
4,000
500
19,538
9,538
3,815
13,815
14,400
28,215
125
NO
118
✔
✔
✔
✔
✔
✔
1,546
118
STRUCTURAL CALCULATIONS
27911 Paseo Nicole
Prepared for:
San Juan Capistrano, CA 92675
Kallen Residence
Rooftop Photovoltaic Array Addition
ISE Project#: 7501.04
December 13, 2023
Engineer Seal
Indigo Solar
26820 Crilly Rd.
Corona, CA 92883
A
TSA
T
O CFE
AI
L FI O NR
No. S5627
Exp. 6/30/2024
L
HETSIGERW
P
ARED R SEFO
N .D
GOIREENOSI
N
LA
RHT
O
NESPS
TRUCT U R A L 40810 County Center Drive, Suite 110 Temecula, CA 92591 P: 951.600.0032 www.ISEengineers.com
DIANNA F.02/07/24B23-1264SUBJECT TO FIELD INSPECTION
Gravity Design Loads:
Roof Type:
Live Load:20.0 psf
Dead Load:
Asphalt Shingle:4.2 psf
Sheathing:1.5 psf
Roof framing members:2.5 psf
Drywall:2.0 psf
Insulation:1.0 psf
Miscellaneous:0.5
Total solar array weight 2.46 psf (Solar panel + Racking + Anchor)
11.70 psf
14.16 psf
31.7 psf
34.2 psf
294 ft2 (Area of affected roof trusses/rafter)
1187 ft2
294 ft2
1187 ft2 (Area of affected LFRS)
Gravity Load Demand-Capacity Ratio: (CEBC Section 502.4)
0.61 psf
1.92% < 5.0%
LFRS Demand-Capacity Ratio: (CEBC Section 502.5)
0.61 psf
5.21% < 10.0%
Photovoltaic Array Addition at Buildings
2022 California Building Code Sections 502.4 & 502.5 - Additions
Total Area of Affected Roof (for lateral check) =
Total Load Increase at Affected Roof =
Area of Solar Array Addition (for lateral check) =
Roof Dead Load w/o Solar Array =
Roof Dead Load w/ Solar Array =
Total Roof Load w/o Solar Array =
Total Roof Load w/ Solar Array =
Area of Solar Array Addition (for gravity check) =
Total Area of Affected Roof (for gravity check) =
Asphalt Shingle roofing w/ 1/2" plywood sheathing over 2x4 rafters at 24"
o.c., 5/8" gypsum board ceiling, insulation, and miscellaneous loading
Percentage of Total Load Increase =
Per 2022 CBC 502.4 additional solar array
weight is structurally acceptable
Dead Load Increase at Entire Roof =
Percent. Dead Load Increase on Entire Roof =
Per 2022 CBC 502.5 additional solar array
weight is structurally acceptable
40810 County Center Drive, Suite 110 Temecula, CA 92591 P: 951.600.0032 www.ISEengineers.com
psf
ft2
Embed, in Z, lb
NDS Table 12K
2.5 220
lb/Mt (Cd=1.6)
lb/Mt (Cd=1.6)
ASCE 7-16, Sec. 11.4.2 Longitude, deg
USGS -117.6435
USGS
Site Coefficient, Fa =
Site Coefficient, Fv =Table 11.4-2
SDS = 2/3 Fa*Ss =ASCE 7-16, EQ 11.4-3
SD1 = 2/3 Fv*S1 =ASCE 7-16, EQ 11.4-4
Importance Factor, Ie =ASCE 7-16, Table 1.5-2
Height of Equipment, z =ft, Sec. 13.3.1.1
Height of Roof, h =ft, Sec. 13.3.1.1
ap =Table 13.6-1
Rp =Table 13.6-1
Fp=(0.4apSDSIp)(1+2z/h)/(Rp/Ip) =EQ 13.3-1
Fp max = 1.6SDSIp =[Not Greater Than]EQ 13.3-2
Fp min = 0.3SDSIp =[Not Less Than]EQ 13.3-3
Sf = Fp/1.4 =Horizontal Seismic Force ASCE 7-16, EQ 12.4-3
Sfv = 0.2SDS/1.4 =Vertical Seismic Force ASCE 7-16, EQ 12.4-4
Vseismic = Sf*Warray*AREAarray =lb, Total Lateral Load on Seismic Anchors
Tseismic = Sfv*Warray*AREAarray =lb, Total Vertical Load on Seismic Anchors
No. of Anchors = Vseismic/Vallow =No. of Required Lateral Load Seismic Anchors
No. of Anchors = Tseismic/Tallow =No. of Required Vertical Load Seismic Anchors
Total No. of Required Anchors =Worst Case Tension or Shear
No. of Anchors Supplied =
1.276
0.239
Solar Array Properties (Per Solar Array Designer)
Warray:2.46
Aarray:294.0
Number of Required Seismic Anchors (Tension & Shear)
361
82
CBC/IBC Alternate Load Combinations (ASD) - Section 1605.3.2, EQ. 16-20 & 16-21
0.499
0.114
1.0
0.1
2
22 Standoff Mounts per solar designer plans
Vallow (NDS Table 12K) :352
1 5/16"266
Tallow (NDS Table 12.2A) :
0.439
1.00
33.5083
1064
1.04
0.798
1.59
16.00
14.00
Determine Fp, Seismic Design Force (STRENGTH LEVEL) - ASCE 7-16 Section 13.3.1
0.699
1.50
1.00
S1 =0.415
Latitude, deg
Design Parameters
Site Class =D
Ss =1.151
Roof Mounted Solar Array - Earthquake Analysis
Earthquake Design per ASCE 7-16 - Section 13.6 (Mechanical/Electrical Components)
Solar Attachment Standoff Anchor:# screws/
standoff Diameter, in W, lb/in
NDS Table 12.2A
Seismic Anchor Properties
40810 County Center Drive, Suite 110 Temecula, CA 92591 P: 951.600.0032 www.ISEengineers.com
PSF
FT2
lb/Mt (Cd=1.6)
lb/Mt (Cd=1.6)
Basic Wind Speed, V :mph (Per ASCE Hazard Tool)
Section 26.7
Total Effective Area of Typical Array :ft2
Panel Area to Each Support :ft2
Angle of Panels :degrees
"a" :ft (3ft. Min.)
ft, above sea level
ft
Section 26.12
Table 1.5-1
qh = 0.00256 Kh Kzt Kd Ke V2 I = psf Load case 0.6*W
Kh =Table 26.10-1
Kzt =Figure 26.8-1
Kd =Table 26.6-1
Ke =Table 26.9-1
I = Table 1.5-1
Internal Pressure Coeff. = (+/-) GCpi =Table 26.13-1
δe = Array edge factor, Figure 29.4-7
δa = Pressure equalization, Figure 29.4-8
Worst Case Zone 1 & 2, Min 100 sf
GCp (Zone 1) =
GCp (Zone 2) =
(+) P = qh (GCp - GCpi) =
Lateral Load at Each Mount =lbs OK < Vallow
Compression / Uplift at Each Mount =lbs OK < Tallow
16.0 -12.2 psf, Positive Wind (16 psf min),
Solar panels located in Zone 1
& 287-66
195 -149
-1.80 Per Figures 30.3-2A thru 30.3-
0.80 -2.20 Per Figures 30.3-2A thru 30.3-
1.00
0.18
1.50
0.40
0.80
Determine Wind Force at Each Roof Mount
10.1
0.86
1.0
0.85
1.00
Structure Risk Category :II
Enclosure Classification :Enclosed
Height above ground level, z :16.0
Ground Elevation, Zg :121
24
3
294
13.36
95
Wind Exposure :C
Design Parameters
Vallow (NDS Table 12K) :352
Wind Anchor Properties (Per Seismic Anchor Check)
Tallow (NDS Table 12.2A) :1064
Aarray :294.0
Roof Mounted Solar Array - MWFRS Wind Analysis
per ASCE 7-16, Sec. 29.4.4 (Solar Panels Parallel to Roof < 2 °)
Solar Array Properties (Per Solar Array Designer)
W array :2.46
40810 County Center Drive, Suite 110 Temecula, CA 92591 P: 951.600.0032 www.ISEengineers.com
Roof Mounted Solar Array - ASCE 7 Hazard Tool - WIND Report
40810 County Center Drive, Suite 110 Temecula, CA 92591 P: 951.600.0032 www.ISEengineers.com
Roof Mounted Solar Array - ASCE 7 Hazard Tool - SEISMIC Report
40810 County Center Drive, Suite 110 Temecula, CA 92591 P: 951.600.0032 www.ISEengineers.com