Loading...
B23-0226 - 32161 CAMINO CAPISTRANOFINAL 07/02/24 Letter of Transmittal 3707 W Garden Grove Blvd. Suite 100, Orange, CA 92868 phone 714.568.1010 fax 714.568.1028 www.csgengr.com ORA – BPR - 160801 To: City of San Juan Capistrano Date: 8/7/2023 32400 Paseo Adelanto CSG #: 433147 San Juan Capistrano, CA 92675 Agency Plan Check #: B23-0326 Attn: Building Department Job Address: 32161 Camino Capistrano Status: Hours: X Plan is approved. 1st plan check Plan is approved with conditions. See remarks. 2nd plan check Plan is approved with redlines. See remarks. 3rd plan check Plan is approved with redlines and conditions. See remarks. 4th plan check Plan requires corrections. See attached list. Total: Other: We have reviewed the following documents ( Digital review only): X Plans Energy Calculations Structural Calculations Specifications Soil Report Special Inspection Form(s) Geotechnical Letter Truss Calculations Special items to note: X Plan has been stamped and signed by CSG Environmental Health Services approval required Special inspection required for Hardship Form included Remarks: Recommend for approval From: Jensen Ku S.E. CSG Consultants BOARD OF DIRECTORS LAURA FREESE CHARLES T. GIBSON SAUNDRA F. JACOBS BETTY H. OLSON, PH.D FRANK URY DANIEL R. FERONS GENERAL MANAGER Santa Margarita Water District  26111 Antonio Parkway, Rancho Santa Margarita, CA 92688 www.SMWD.com  (949) 459-6420 February 28, 2023 Building Department City of San Juan Capistrano 32400 Paseo Adelanto San Juan Capistrano, California 92675 Attention: Building Department Subject: Final Water and Sewer Letter for T Mobile at 32161 Camino Capistrano, San Juan Capistrano, TR 108 in Improvement District No. 9 Dear Building Department: Subject to the developer’s successful completion of the on-site water and sewer facilities, and subject to the availability of water from the Metropolitan Water District of Southern California, the District can and will provide water and sewer service to the subject project. This approval is only for the issuance of building permits and is only good for two years from the date of this letter. At this time, no further inspection of the on-site water and sewer facilities is needed by SMWD to enable the City to release the certificate of occupancy. However, The District still reserves the right to inspect the on-site plumbing and backflow prevention when necessary. Use of self-regenerative water softeners is discouraged within the District and application for use at this site has not been approved. The following is a list of all fixtures that will discharge to the sanitary sewer: • 2 Hand Sinks • 1 Mop Sink • 2 Floor Drains • 1 Utility Sink • 2 Toilets • 1 Water Cooler Should you have any questions or desire additional information, please call the Engineering Counter at 949.459.6503. Sincerely, SANTA MARGARITA WATER DISTRICT Patricia Butler Chief Engineer S:\Finalws\ TR108 TMobile SJC.doc.bp cc: SMWD Cross Connections SOCWA 2.5 CSG 02/09/24