B20-0417 - 31341 YSIDORA STCITY OF SAN JUAN CAPISTRANO
BUILDING PERMIT
Permit No. B20-0417
04/30/2020
ISSUED
JOB VALUE
NO UNITS
Permit Number
ISSUED BY
SITE APN
SITE LOT NO
SITE TRACT
SITE SUBDIVISION
PERMIT TYPE.
OCCUPANCY TYPE
BUILDING SF
NO STORIES
RS2
124-190-04
R3
4
808
$0
ELECTRICAL
0
1
1
JOB ADDRESS: 31341 YSIDORA ST
MC KEAGUE, JOHN E & SHARON AOWNER NAME
31341 YSIDORA STMAILING ADDRESS
CITY,STATE,ZIP
CONTRACTOR NAME
ST. LIC EXPIRE
ADDRESS
CITY, ST, ZIP
TENANT NAME
PHONE #
MAILING ADDR
CITY, ST, ZIP
I have carefully examined the completed permit application and do hereby certify under penalty of
perjury that all information hereon including the declarations are true and correct and I further
certify and agree if a permit is issued: to comply with all City, County, and State laws governing
building construction, whether specified herein or not. I also agree to save, indemnify and keep
harmless the City of San Juan Capistrano against all liabilities, judgments, costs and expenses
which may in any way accrue against said City in consequence of the granting of this permit.
Applicant's signature
Owner/Contractor
Print Name
ROCK MOUNTAIN ELECTRIC
410 SAN DIEGO STREET #A3
09/30/2020
AMOUNT
MECHANICAL PERMIT AMOUNT
Expiration:: Every permit issued shall become invalid unless the work on the site authorized by
such permit is commenced within 12 months after its issuance, or if the work authorized on the
site by such permit is suspended or abandoned for a period of 180 days after the time the work
commenced.
An OSHA permit is required for excavations over 5’0” deep and demolition or construction of
structures over 3 stories in height.
_____Contractor:I hereby affirm that I am licensed under provisions of Chapter 9 of Division 3 of the Business and Professions Code, and my license is in full force and effect.
_____Owner/Builder:I, as owner of the property, or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale. (Sec.7044, Business and Professions Code: the Contractor’s License Laws does not apply to and owner of property who builds or improves thereon, who does such work himself or through his employees, provided that such improvements are not
intended or offered for sale. If however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
______Owner/Builder:I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor’s License Law does not
apply to an owner of property who builds or improves thereon and who contracts for such projects with a contractor’s) license pursuant to the Contractor’s License Law.
_______ Workers Compensation-I hereby affirm under penalty of perjury one of the following declarations:I have and will maintain workers’ compensation insurance, as required by Section 3700 of the
Labor Code, for the performance of the work for which this permit is issued. My workers’ compensation insurance carrier and policy number are: Carrier__NORGUARD INSURANCE COMPANY
Policy#ROWC155885 (This section needs to be completed if the permit is for one hundred dollars($100) or less)
AMOUNTELECTRICAL PERMIT
DESCRIPTION
_______Exemption:I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers’ compensation laws of
California and agree that if I should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions.
WARNING:FAILURE TO SECURE WORKERS’COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TI CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED
THOUSDAND DOLLARS($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
B20-0417
SERVICES 600V OR LESS NOT OVER 200AMPS 33.78
ELECTRICAL ISSUANCE FEE 27.24
Total Electrical 61.02
Total Plumbing
Total Mechanical
Total Mobile Home
1008912
,
OCEANSIDE, CA 92054
SAN JUAN CAPISTRANO, CA 92675
(949) 370-7000
(760) 755-8533
PHONE
PHONE
Date _________________ Applicant _______________________________________
MOBILE HOME PERMIT AMOUNT
MAIN PANEL UPGRADE - 200A
PLUMBING PERMIT
NO FINAL INSPECTION CALLED
EXPIRED 12/03/2020
Date:
Permit No.
Applicant:
Phone/E-Mail
Job Location:
CITY OF SAN JUAN CAPISTRANO
BUILDING PERMIT FEES
Account # Type Cost
01-44221 Building Permit
01-44223 Mechanical
01-44224 Plumbing
01-44225 Electrical
01-44221 Mobile Home Permit
01-44222 Grading Permit Fee
01-44231 Grading Plan Check
01-44222 On-Site Residential Permit
01-44231 On-Site Residential Plan Check
Subtotal
01-44230 Bond Processing
01-44230 Building Plan Check
01-44230 Additional Plan Check
01-44230 Digital Record Fee ($1.00 per sheet)
01-44221 C & D Administrative Fee
01-44221 Special Inspection-Reinspection
01-44222 On-Site Commercial/Tract Permit Fee
01-44231 On-Site Commercial/Tract Plan Check Fee
01-44214 Geotechnical Soils Plan Review
10-44320 Ordinance 211
10-42510 Ordinance 364
01-45354 Copies @ .20 Each
90-23331 SMIP Fee
33-44370 H.O.P.E. Fee (Housing in Lieu)
Other Fees
TCA Fees Date Received
HOA Approval Date Received
School Fees Date Received
Engineering Fees Date Received
Water Division Fees Date Received
01-44221
01-44221
01-44240
90-23000
90-23000
TOTAL FEES PAYABLE TO CITY OF SAN JUAN CAPISTRANO
Receipt # _________ Date: ______________ Cashier: _____________________________
Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type
Title 24 Energy Provision (20% Permit Subtotal & Bldg Plan Check))
Title 24 ADA Fee (10% Permit Subtotal & Bldg Plan Check)
Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type
NPDES Permit Fee (10% Permit Subtotal)
$0.00
$ 61.02
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$ 22.80
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$6.10
$0.00
9/26/2023
$ 89.92
$0.00
$ 61.02
9/26/2023
B20-0417
ROCK MOUNTAIN ELECTRIC
31341 YSIDORA ST
75374
(442) 288-7786
$0.00
NEC Standard Electrical Load Calculation for Single Family Dwellings
(Only for Service Ratings of 120/240V, 225 Amps Max)
Owner: Location:
Total Floor Area of Dwelling (NEC 220.12) SQFT.
Factor Quantity Volt Amperes
(VA)
“General Lighting”
1. General Lighting (SQFT X 3 VA/SQ FT (Table 220.12)3 X sqft.
2. Small Appliance Circuits (1500 VA per circuit) (NEC
220.52(A)) (minimum 2)1500 X
3. Laundry Circuit (1500 VA per circuit) (NEC 220.52(B))1500 X
4. Total General Lighting Load (Add lines 1, 2 & 3):
5. First 3000 VA @ 100%:3000
6. Total General Lighting Load – 3000 = @ 35%=
7.Net General Lighting Load (Per NEC 220.42) (Add lines 5 & 6):
*Fixed Appliances(if insufficient space, use back):YES NO
Garbage Disposal
Bathroom Fan
Microwave
Dishwasher
Other:
Other:
Total
8. 3 or less Appliances, Total Appliance VA;
4 or more Appliances, 75% of Total Appliance VA (NEC 220.53):
*Other Loads (including motors, EV charger(s), etc.)YES NO Nameplate Rating
(VA)
9. Electric Range (8000VA or Nameplate)**
10.HVAC
11. Electric Oven
12. Electric Dryer (5000 VA minimum)**
13. Electric Vehicle Charger
14. Other:
15. Other:
16. 25% of largest motor (NEC 430.24)
Total Service Load Volt-Amperes (VA) (Add lines 7, 8 & 9 thru 16) =
Total Service Load Volt-Amperes / 240-volts = Amperes
***Service Rating (Amperes)=
* For every “YES” answer, indicate VA rating of equipment
** Nameplate rating must be used if larger
*** Service Rating shall be greater than or equal to the Service load
As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of
disability and, upon request will provide reasonable accommodation to ensure equal access to its programs, services and activities.
NEC Standard Electrical Load Calculation (Rev. 03-23-2016) www.sanjuancapistrano.org
Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog3-43MURRAYLoad Centersa 100-225A only.
b This information is based on use of 10,000 AIC rated branch circuit breakers in load center (MP-T, MH-T, MP-GT, MG). Most series ratings exclude MH-T above 40 Amp. Consult device wiring diagram for spe-cific data.
Remote Only
Types MQH & MQL may be mounted internal in 150-225 amp 3Ø main breaker load centers.
Dimensions shown are representative of outside box length, width & depth (±1⁄8”) and do not include allowance for mounting bumps, endwalls, hubs or hardware protru-sions. Allow approximately 11⁄4” additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required.
Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub.
Standard package quantity equal to 1.
Copper bus load centers are recommended for those applications where the environment may be severe (ie farm and coastal areas).
Rock Solid Load Centers
Main Breaker, 1Ø, 22,000 AICa
Load Center Short Circuit Current Rating
Copper Bus
Amps No. of Max. Indoor Type 1 Dimensions Max. Spaces Circuit Catalog Number Height Width Depth100 20 40 LC2040B1100CU 24 143⁄8 4200 20 40 LC2040B1200CU 30 143⁄8 4200 30 40 LC3040B1200CU 36 143⁄8 4200 40 40 LC4040B1200CU 39 143⁄8 4
Load Center Short Circuit Current Rating
Load Center Internal or RemoteShort Circuit Load Center Main or FeederCurrent Ratingb Main Rating Circuit Breaker Type10,000 AIC Any Any22,000 AIC 100/125A MP-HT, MQH
150/200/225A MD-H, MQHb, MPP-HT
42,000 AIC 100/125A MQL
150/200/225A MQLb
65,000 AIC 100/125A MP-MT, MPP-MT
150/200/225A MPP-MT
100,000 AIC 100/125A 100A, 300V AC, Class “T” Fuse
100,000 AIC 150/200/225A 200A, 300V AC, Class “T” Fuse
LC2040B1200
Load centers on this page through 200 amp feature a new split neutral with
one bonded and one insulated bar. For service entrance applications, install
bonding strap, and use both bars for neutral and ground conductors. For non
service entrance applications, do not install bonding strap and use insulated
bar for neutral conductors and bonded bar for ground conductors.
Siemens / Speedfax Previous folio: Murray SS 2/14/11
12-42 Circuit, 100-200 Amperes
AmpsMax.No. ofSpaces Max.Circuit
Catalog Number Dimensions
Outdoor Type 3RDimensions
Indoor Type 1Height Width Depth Catalog Number Height Width Depth
100 12 24 LC1224B1100 18 14
3⁄8 4 LW1224B1100 23 14
1⁄4 41⁄2
100 16 32 —— — —LW1632B1100 23 14
1⁄4 41⁄2100 20 40 LC2040B1100 24 14
3⁄8 4 —— — —
100 24 40 LC2440B1100 24 14
3⁄8 4 —— — —
100 30 40 LC3040B1100 30 14
3⁄8 4 —— — —
150 16 32 LC1632B1150 24 14
3⁄8 4 —— — —
150 20 40 LC2040B1150 30 14
3⁄8 4 LW2040B1150 29 14
1⁄4 41⁄2150 24 40 LC2440B1150 30 14
3⁄8 4 —— — —
150 30 40 LC3040B1150 36 14
3⁄8 4 —— — —
200 12 24 —— — —LW1224B1200 29 14
1⁄4 41⁄2
200 16 32 LC1632B1200 30 14
3⁄8 4 —— — —
200 20 40 LC2040B1200 30 14
3⁄8 4 LW2040B1200 29 14
1⁄4 41⁄2
200 24 40 LC2440B1200 30 14
3⁄8 4 —— — —
200 30 40 LC3040B1200 36 14
3⁄8 4 LW3040B1200 38 14
1⁄4 41⁄2
200 40 40 LC4040B1200 39 14
3⁄8 4 LW4040B1200 38 14
1⁄4 41⁄2200 30 54 LC3054B1200 36 14
3⁄8 4 —— — —
200 40 40 LC4040B1200 39 14
3⁄8 4 —— — —
200 40 60 LC4060B1200 401⁄2 157⁄8 5 —— — —
Product Category RESI
Murray load centers have UL recognized
short circuit current ratings up to 100,000
Amps, when used with appropriate main
or feeder (remote or internal) overcurrent
devices. Load center ratings are shown
below. For load center applications
with residential or commercial metering
equipment, refer to the appropriate
catalog section.
1Ø, main breaker load centers are
Underwriter’s Laboratories Listed
for use with 60/75°C conductors and
accept Murray branch circuit breakers
which are also UL Listed for use
with 60/75°C conductors. Type 3R
load centers are furnished with a hub
opening closure plate.B20-0417 B-1
2.50/[64] MAX 7.36
A HUB [ 187]
(2 LOCATIONS) SUPPLIED WITH I+ I
CLOSING PLATE \ -,
.62
[16]
.44
[ 11]
OPTIONAL OVERHEAD BARRIER TUNNEL KIT. ORDER CAT NO OHBS WHEN REQUIRED FOR LOAD WIRES TO EXIT TOP ENDWALL. CONSULT
1 0.89 UTILITY FOR APPROVAL.
17.67 [277]]
[449] 14.78
[375] L_�
---+----------'
41.16
[1046] METER COVER LATCH AND SEAL BRACKET
NOTES:
COVER KNOCKOUT FOR USE WITH UTILITY BARREL LOCK
UTILITY WIREWAY SEAL BRACKET
2.39
[61]
E,F,G,H
<J
18.76
[ 477]
-------
12.18
[309]
----i
2.80
[71]
COVER LATCH
D,F,G
(2 PLACES)
t 2.69
[68]
6.36
[162]
A,B,C
2.45
[62]
(9 PLACES)
A,B,C
FINISH -GRAY BAKED ENAMEL POWDER COAT PAINT OVER CLEANED GALVANNEALED STEEL.
.50
[13]
DIA
.63 DIA
[16] n 5.41
[137]
C,E,F
3.13
[80]
1.87
[ 48]
MAXIMUM SYSTEM VOLTAGE: 120/240VAC, 103W, 50-60HZ, 208Y/120VAC, 103W, 50-60HZ (FROM A 304W SYSTEM) UL LISTED -FILE E-6294, VOL M SUITABLE ONLY FOR USE AS SERVICE EQUIPMENT.
SUITABLE FOR UNDERGROUND/OVERHEAD SERVICE.
JUNE 2017
LINE ¢ ¢
SERVICE GROUND LUG
BRANCH NEUTRAL, EQUIPMENT GROUNDING AND ALTERNATE SERVICE GROUND TERMINALS
SERVICE DISCONNECT 200A MAX V OPTIONAL EQUIPMENT GROUND BAR LOCATION
e----G-ONE SINGLE POLE, ONE PLUG-ON SPACE TYPE QO. TWO POLE TYPE QO, QOA, OR QOC (125A MAX) MAY PLUG-ON TWO
ADJACENT SPACES. TWO POLE TYPE QOC (150-200A) MAY PLUG
ON FOUR ADJACENT SPACES.
� TWO SINGLE POLE, ONE PLUG-ON SPACE TYPE QOT OR ONESINGLE POLE TYPE QO. TWO POLE TYPES QO, QOA, OR QOC
(125A MAX) MAY PLUG-ON TWO ADJACENT SPACES. TWO POLE TYPE QOC (150-200A) MAY PLUG ON FOUR ADJACENT SPACES.
TOTAL CIRCUIT BREAKER HANDLE RATING NOT TO EXCEED 160A PER CIRCUIT CONNECTOR.
A SQUARE D UL LISTED SECONDARY SURGE ARRESTER MAY PLUG ON TWO ADJACENT SPACES. ORDER CATALOG NO Q02175SB.
MAINS FACTORY SHORT INSTALLED CIRCUIT CATALOG AMPERE BYPASS CURRENT NUMBER SERIES SPACES
RATING TYPE RATING
200 HORN 22K QC3040M200SH M01 30
200 NONE 22K QC3040M200S M01 30
KNOCKOUTS
SYMBOL CONDUIT SIZE
IN MM
A
B
C
D
E
F
G
H
.50
.75
1.00
1.25
1.50
2.00
2.50
3.00
.09 DIA
[3]
13
19
25
32
38
51
64
76
HOLE DIA
IN MM
.87 22
1.12 28
1.37 35
1.75 44
2.00 51
2.50 64
3.00 76
3.62 92
.09 X .33
[3][9]METER COVER LATCH
MAXIMUM NUMBER OF SINGLE POLE QO CIRCUITS
40
40
SEAL BRACKEr UTILITY WIREWAY
SLOT
. INCHES DUAL DIMENSIONS. MILLIMETERS
LINE SIDE PHASE & SERVICE
NEUTRAL LUGS GROUND LUG
AWG/KCMIL AWG
#6-350 CU/AL #14-20 cu
#12-20 AL
#6-350 CU/AL #14-20 cu
#12-20 AL
SQUARE E:] ,.
by Schnelder Electric
COMBINATION SERVICE ENTRANCE DEVICES RINGLESS TYPE ALL-IN-ONE QO 30-40 CIRCUIT RAINPROOF NEMA TYPE 3R ENCLOSURE SURFACE MOUNT DWG# PWFDS-SYRS-0049 NO.
PWFDS-SYRS-0049
B20-0417 B-1
Panel Schedule
Panel ID
Panel Location
Fed From
Amps Single Phase
Three Phase
Main Breaker
Main Lugs Only
Fed-thru Lugs
Breaker Details Phase TypeGeneral Information
Notes
Brkr Pole Wire
(AWG)
Pipe
Size
VA Voltage Description Ckt Ckt Description Voltage VA Pipe Size Wire Size
(AWG)
Pole Brkr
120 / 240
120 / 208
277/ 480
Voltage Type
120 / 240 1
120 / 240 3
120 / 240 5
120 / 240 7
120 / 240 9
120 / 240 11
120 / 240 13
120 / 240 15
120 / 240 17
120 / 240 19
120 / 240 21
120 / 240 23
120 / 240 25
120 / 240 27
120 / 240 29
120 / 240 31
120 / 240 33
120 / 240 35
120 / 240 37
120 / 240 39
120 / 240 41
2 120 / 240
4 120 / 240
6 120 / 240
8 120 / 240
10 120 / 240
12 120 / 240
14 120 / 240
16 120 / 240
18 120 / 240
20 120 / 240
22 120 / 240
24 120 / 240
26 120 / 240
28 120 / 240
30 120 / 240
32 120 / 240
34 120 / 240
36 120 / 240
38 120 / 240
40 120 / 240
42 120 / 240
B20-0417 B-1
Additional Address Info:
Metering: Meter Clips: 4
Utilities Maximum Contribution to Fault Current: 10000Phase: 1# of Wires: 3
Voltage: 120/240
Temp Service Charge due on First Bill $ 0.00
Provide Minimum Ground Clearance Of:
_10_ Ft. From bottom of drip loop at service wire point of attachment
_12_ Ft. Over driveway or parking area
_16_ Ft. At outer limit of vehicular traffic
_2_ Ft. Minimum rigid riser above roof
__ Ft.
Assessor's Parcel Number:
If SDG&E encounters hazardous or toxic material while performing construction of your project, SDG&E will halt work immediately and it will
be your responsibility to remove and or clean up all hazardous or toxic material prior to SDG&E continuing construction. SDG&E shall have no
liability or obligation whatsoever to cleanup, remove or remediate any hazardous or toxic materials discovered during the course of
construction unless it is through negligence of SDG&E.
Customer-owned facilities to receive gas service are subject to all applicable local and state of California inspection authority requirements.
Building address and/or houseline must be permanently identified prior to meter set. Information on this sheet is void after six (6) months.
Keep this notice with building permit.
All installations performed under this order must meet SDG&E standards unless a written deviation has been approved.
Additional Information:
To minimize the electrical outage, you are advised to schedule a morning disconnect with an afternoon reconnect. There is no charge
for this service. Before you change out your meter consider (1) SDG&E needs 10 working days advance notice to schedule a crew and
(2) SDG&E will not reconnect the service without municipal approval on the new panel. Please contact the City of San Clemente
regarding permits and inspections. City inspection should be received prior to 2:00 p.m. on the same day as the disconnection of
service to allow the SDG&E crew enough time for reconnection of the service on the same day.
Number/Size of Main Switch: 1/200Service Panel Rating: 200
Customer Phone #: 951-600-0654Customer POC: Fran Moran
Wanted Date: O/I
Job #: 530000187573
ELECTRIC OVERHEAD METER & SERVICE LOCATION
Customer Copy
Project Title: MCKEAGUE RESIDENCE SOT OH RELOCATE
Notification #: 300000331921
Project Address: 31341 YSIDORA ST
Customer Type: Residential(1-2 Units)
Date Prepared: 04/15/2020
Project City: SAN JUAN CAPISTRANO
SDGE Contact: Service Coordinator Contact Info: SERVCIE DESK, 949-361-8066
Planned By: Edward Salsido Phone#: 9493618081
Service Type: OH SERVICE REWIRE/RELOCATION
TB: 0952-C7
SERVICE ATTACHMENT POINT AND/OR METER LOCATION:
Locate the new point of attachment within 18 inches of the middle of Westerly wall (see sketch). Install rigid riser minimum of 2
feet above roof and meet minimum clearances as noted below. Locate new 200-amp meter panel on the Westerly wall at new location.
CALL (949)361-8066 to set up the Disconnect - Crew will Reconnect (same day) "On City Inspection" - Inspection must be received
before 2pm. IMPORTANT:"Should the Customer cancel the Crew work less than 24hrs of the scheduled date or onsite, the Requestor will
be billed a non-refundable fee to cover the Lost Crew time caused by the lack of adequate notice. These charges must be paid prior
to rescheduling the work."
SDG&E Application Required-Call: 1-800-411-7343
Municipal Inspection Required By: CITY OF SAN JUAN CAPISTRANO
Traffic Control Permit Required
Excavation/Encroachment Permits Required By:
Right of Way Required
Meter height -- 4'0'' min. (3'0" min. for multiple installation) -- 6'3" max. From finish grade to centerline of meter base. Meters are required to
be readily accessible 24 hours per day. Meters must be located in a safe area free of any potentially hazardous or dangerous condition.
Provide 3-ft. x 3-ft. clear and level working space in front of meter. Where meter room is proposed, contact the planner at the nearest SDG&E
office. Meter bases and meter service disconnects must be located at or immediately adjacent to each other and be identified with address
and unit number it serves.B20-0417 B-1
Last Revised: March 13, 2015
OH Relocation/31341 Ysidora St. SJ
Notification #:3-331921 DATE: 4/16/2020
SDG&E CONTACT:
Service Desk
949-361-8066 B20-0417 B-1