Loading...
B20-0417 - 31341 YSIDORA STCITY OF SAN JUAN CAPISTRANO BUILDING PERMIT Permit No. B20-0417 04/30/2020 ISSUED JOB VALUE NO UNITS Permit Number ISSUED BY SITE APN SITE LOT NO SITE TRACT SITE SUBDIVISION PERMIT TYPE. OCCUPANCY TYPE BUILDING SF NO STORIES RS2 124-190-04 R3 4 808 $0 ELECTRICAL 0 1 1 JOB ADDRESS: 31341 YSIDORA ST MC KEAGUE, JOHN E & SHARON AOWNER NAME 31341 YSIDORA STMAILING ADDRESS CITY,STATE,ZIP CONTRACTOR NAME ST. LIC EXPIRE ADDRESS CITY, ST, ZIP TENANT NAME PHONE # MAILING ADDR CITY, ST, ZIP I have carefully examined the completed permit application and do hereby certify under penalty of perjury that all information hereon including the declarations are true and correct and I further certify and agree if a permit is issued: to comply with all City, County, and State laws governing building construction, whether specified herein or not. I also agree to save, indemnify and keep harmless the City of San Juan Capistrano against all liabilities, judgments, costs and expenses which may in any way accrue against said City in consequence of the granting of this permit. Applicant's signature Owner/Contractor Print Name ROCK MOUNTAIN ELECTRIC 410 SAN DIEGO STREET #A3 09/30/2020 AMOUNT MECHANICAL PERMIT AMOUNT Expiration:: Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work commenced. An OSHA permit is required for excavations over 5’0” deep and demolition or construction of structures over 3 stories in height. _____Contractor:I hereby affirm that I am licensed under provisions of Chapter 9 of Division 3 of the Business and Professions Code, and my license is in full force and effect. _____Owner/Builder:I, as owner of the property, or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale. (Sec.7044, Business and Professions Code: the Contractor’s License Laws does not apply to and owner of property who builds or improves thereon, who does such work himself or through his employees, provided that such improvements are not intended or offered for sale. If however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) ______Owner/Builder:I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor’s License Law does not apply to an owner of property who builds or improves thereon and who contracts for such projects with a contractor’s) license pursuant to the Contractor’s License Law. _______ Workers Compensation-I hereby affirm under penalty of perjury one of the following declarations:I have and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers’ compensation insurance carrier and policy number are: Carrier__NORGUARD INSURANCE COMPANY Policy#ROWC155885 (This section needs to be completed if the permit is for one hundred dollars($100) or less) AMOUNTELECTRICAL PERMIT DESCRIPTION _______Exemption:I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California and agree that if I should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING:FAILURE TO SECURE WORKERS’COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TI CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSDAND DOLLARS($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. B20-0417 SERVICES 600V OR LESS NOT OVER 200AMPS 33.78 ELECTRICAL ISSUANCE FEE 27.24 Total Electrical 61.02 Total Plumbing Total Mechanical Total Mobile Home 1008912 , OCEANSIDE, CA 92054 SAN JUAN CAPISTRANO, CA 92675 (949) 370-7000 (760) 755-8533 PHONE PHONE Date _________________ Applicant _______________________________________ MOBILE HOME PERMIT AMOUNT MAIN PANEL UPGRADE - 200A PLUMBING PERMIT NO FINAL INSPECTION CALLED EXPIRED 12/03/2020 Date: Permit No. Applicant: Phone/E-Mail Job Location: CITY OF SAN JUAN CAPISTRANO BUILDING PERMIT FEES Account # Type Cost 01-44221 Building Permit 01-44223 Mechanical 01-44224 Plumbing 01-44225 Electrical 01-44221 Mobile Home Permit 01-44222 Grading Permit Fee 01-44231 Grading Plan Check 01-44222 On-Site Residential Permit 01-44231 On-Site Residential Plan Check Subtotal 01-44230 Bond Processing 01-44230 Building Plan Check 01-44230 Additional Plan Check 01-44230 Digital Record Fee ($1.00 per sheet) 01-44221 C & D Administrative Fee 01-44221 Special Inspection-Reinspection 01-44222 On-Site Commercial/Tract Permit Fee 01-44231 On-Site Commercial/Tract Plan Check Fee 01-44214 Geotechnical Soils Plan Review 10-44320 Ordinance 211 10-42510 Ordinance 364 01-45354 Copies @ .20 Each 90-23331 SMIP Fee 33-44370 H.O.P.E. Fee (Housing in Lieu) Other Fees TCA Fees Date Received HOA Approval Date Received School Fees Date Received Engineering Fees Date Received Water Division Fees Date Received 01-44221 01-44221 01-44240 90-23000 90-23000 TOTAL FEES PAYABLE TO CITY OF SAN JUAN CAPISTRANO Receipt # _________ Date: ______________ Cashier: _____________________________ Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type Title 24 Energy Provision (20% Permit Subtotal & Bldg Plan Check)) Title 24 ADA Fee (10% Permit Subtotal & Bldg Plan Check) Refundable Bond/Deposit Posted by ______Owner_____Contractor ________Type NPDES Permit Fee (10% Permit Subtotal) $0.00 $ 61.02 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $ 22.80 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $6.10 $0.00 9/26/2023 $ 89.92 $0.00 $ 61.02 9/26/2023 B20-0417 ROCK MOUNTAIN ELECTRIC 31341 YSIDORA ST 75374 (442) 288-7786 $0.00 NEC Standard Electrical Load Calculation for Single Family Dwellings (Only for Service Ratings of 120/240V, 225 Amps Max) Owner: Location: Total Floor Area of Dwelling (NEC 220.12) SQFT. Factor Quantity Volt Amperes (VA) “General Lighting” 1. General Lighting (SQFT X 3 VA/SQ FT (Table 220.12)3 X sqft. 2. Small Appliance Circuits (1500 VA per circuit) (NEC 220.52(A)) (minimum 2)1500 X 3. Laundry Circuit (1500 VA per circuit) (NEC 220.52(B))1500 X 4. Total General Lighting Load (Add lines 1, 2 & 3): 5. First 3000 VA @ 100%:3000 6. Total General Lighting Load – 3000 = @ 35%= 7.Net General Lighting Load (Per NEC 220.42) (Add lines 5 & 6): *Fixed Appliances(if insufficient space, use back):YES NO Garbage Disposal Bathroom Fan Microwave Dishwasher Other: Other: Total 8. 3 or less Appliances, Total Appliance VA; 4 or more Appliances, 75% of Total Appliance VA (NEC 220.53): *Other Loads (including motors, EV charger(s), etc.)YES NO Nameplate Rating (VA) 9. Electric Range (8000VA or Nameplate)** 10.HVAC 11. Electric Oven 12. Electric Dryer (5000 VA minimum)** 13. Electric Vehicle Charger 14. Other: 15. Other: 16. 25% of largest motor (NEC 430.24) Total Service Load Volt-Amperes (VA) (Add lines 7, 8 & 9 thru 16) = Total Service Load Volt-Amperes / 240-volts = Amperes ***Service Rating (Amperes)= * For every “YES” answer, indicate VA rating of equipment ** Nameplate rating must be used if larger *** Service Rating shall be greater than or equal to the Service load As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request will provide reasonable accommodation to ensure equal access to its programs, services and activities. NEC Standard Electrical Load Calculation (Rev. 03-23-2016) www.sanjuancapistrano.org Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog3-43MURRAYLoad Centersa 100-225A only. b This information is based on use of 10,000 AIC rated branch circuit breakers in load center (MP-T, MH-T, MP-GT, MG). Most series ratings exclude MH-T above 40 Amp. Consult device wiring diagram for spe-cific data.  Remote Only  Types MQH & MQL may be mounted internal in 150-225 amp 3Ø main breaker load centers.  Dimensions shown are representative of outside box length, width & depth (±1⁄8”) and do not include allowance for mounting bumps, endwalls, hubs or hardware protru-sions. Allow approximately 11⁄4” additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required.  Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub.  Standard package quantity equal to 1.  Copper bus load centers are recommended for those applications where the environment may be severe (ie farm and coastal areas). Rock Solid Load Centers Main Breaker, 1Ø, 22,000 AICa Load Center Short Circuit Current Rating Copper Bus Amps No. of Max. Indoor Type 1 Dimensions Max. Spaces Circuit Catalog Number Height Width Depth100 20 40 LC2040B1100CU 24 143⁄8 4200 20 40 LC2040B1200CU 30 143⁄8 4200 30 40 LC3040B1200CU 36 143⁄8 4200 40 40 LC4040B1200CU 39 143⁄8 4 Load Center Short Circuit Current Rating Load Center Internal or RemoteShort Circuit Load Center Main or FeederCurrent Ratingb Main Rating Circuit Breaker Type10,000 AIC Any Any22,000 AIC 100/125A MP-HT, MQH 150/200/225A MD-H, MQHb, MPP-HT 42,000 AIC 100/125A MQL 150/200/225A MQLb 65,000 AIC 100/125A MP-MT, MPP-MT 150/200/225A MPP-MT 100,000 AIC 100/125A 100A, 300V AC, Class “T” Fuse 100,000 AIC 150/200/225A 200A, 300V AC, Class “T” Fuse LC2040B1200 Load centers on this page through 200 amp feature a new split neutral with one bonded and one insulated bar. For service entrance applications, install bonding strap, and use both bars for neutral and ground conductors. For non service entrance applications, do not install bonding strap and use insulated bar for neutral conductors and bonded bar for ground conductors. Siemens / Speedfax Previous folio: Murray SS 2/14/11 12-42 Circuit, 100-200 Amperes AmpsMax.No. ofSpaces Max.Circuit Catalog Number Dimensions Outdoor Type 3RDimensions Indoor Type 1Height Width Depth Catalog Number Height Width Depth 100 12 24 LC1224B1100 18 14 3⁄8 4 LW1224B1100 23 14 1⁄4 41⁄2 100 16 32 —— — —LW1632B1100 23 14 1⁄4 41⁄2100 20 40 LC2040B1100 24 14 3⁄8 4 —— — — 100 24 40 LC2440B1100 24 14 3⁄8 4 —— — — 100 30 40 LC3040B1100 30 14 3⁄8 4 —— — — 150 16 32 LC1632B1150 24 14 3⁄8 4 —— — — 150 20 40 LC2040B1150 30 14 3⁄8 4 LW2040B1150 29 14 1⁄4 41⁄2150 24 40 LC2440B1150 30 14 3⁄8 4 —— — — 150 30 40 LC3040B1150 36 14 3⁄8 4 —— — — 200 12 24 —— — —LW1224B1200 29 14 1⁄4 41⁄2 200 16 32 LC1632B1200 30 14 3⁄8 4 —— — — 200 20 40 LC2040B1200 30 14 3⁄8 4 LW2040B1200 29 14 1⁄4 41⁄2 200 24 40 LC2440B1200 30 14 3⁄8 4 —— — — 200 30 40 LC3040B1200 36 14 3⁄8 4 LW3040B1200 38 14 1⁄4 41⁄2 200 40 40 LC4040B1200 39 14 3⁄8 4 LW4040B1200 38 14 1⁄4 41⁄2200 30 54 LC3054B1200 36 14 3⁄8 4 —— — — 200 40 40 LC4040B1200 39 14 3⁄8 4 —— — — 200 40 60 LC4060B1200 401⁄2 157⁄8 5 —— — — Product Category RESI Murray load centers have UL recognized short circuit current ratings up to 100,000 Amps, when used with appropriate main or feeder (remote or internal) overcurrent devices. Load center ratings are shown below. For load center applications with residential or commercial metering equipment, refer to the appropriate catalog section. 1Ø, main breaker load centers are Underwriter’s Laboratories Listed for use with 60/75°C conductors and accept Murray branch circuit breakers which are also UL Listed for use with 60/75°C conductors. Type 3R load centers are furnished with a hub opening closure plate.B20-0417 B-1 2.50/[64] MAX 7.36 A HUB [ 187] (2 LOCATIONS) SUPPLIED WITH I+ I CLOSING PLATE \ -, .62 [16] .44 [ 11] OPTIONAL OVERHEAD BARRIER TUNNEL KIT. ORDER CAT NO OHBS WHEN REQUIRED FOR LOAD WIRES TO EXIT TOP ENDWALL. CONSULT 1 0.89 UTILITY FOR APPROVAL. 17.67 [277]] [449] 14.78 [375] L_� ---+----------' 41.16 [1046] METER COVER LATCH AND SEAL BRACKET NOTES: COVER KNOCKOUT FOR USE WITH UTILITY BARREL LOCK UTILITY WIREWAY SEAL BRACKET 2.39 [61] E,F,G,H <J 18.76 [ 477] ------- 12.18 [309] ----i 2.80 [71] COVER LATCH D,F,G (2 PLACES) t 2.69 [68] 6.36 [162] A,B,C 2.45 [62] (9 PLACES) A,B,C FINISH -GRAY BAKED ENAMEL POWDER COAT PAINT OVER CLEANED GALVANNEALED STEEL. .50 [13] DIA .63 DIA [16] n 5.41 [137] C,E,F 3.13 [80] 1.87 [ 48] MAXIMUM SYSTEM VOLTAGE: 120/240VAC, 103W, 50-60HZ, 208Y/120VAC, 103W, 50-60HZ (FROM A 304W SYSTEM) UL LISTED -FILE E-6294, VOL M SUITABLE ONLY FOR USE AS SERVICE EQUIPMENT. SUITABLE FOR UNDERGROUND/OVERHEAD SERVICE. JUNE 2017 LINE ¢ ¢ SERVICE GROUND LUG BRANCH NEUTRAL, EQUIPMENT GROUNDING AND ALTERNATE SERVICE GROUND TERMINALS SERVICE DISCONNECT 200A MAX V OPTIONAL EQUIPMENT GROUND BAR LOCATION e----G-ONE SINGLE POLE, ONE PLUG-ON SPACE TYPE QO. TWO POLE TYPE QO, QOA, OR QOC (125A MAX) MAY PLUG-ON TWO ADJACENT SPACES. TWO POLE TYPE QOC (150-200A) MAY PLUG ON FOUR ADJACENT SPACES. � TWO SINGLE POLE, ONE PLUG-ON SPACE TYPE QOT OR ONESINGLE POLE TYPE QO. TWO POLE TYPES QO, QOA, OR QOC (125A MAX) MAY PLUG-ON TWO ADJACENT SPACES. TWO POLE TYPE QOC (150-200A) MAY PLUG ON FOUR ADJACENT SPACES. TOTAL CIRCUIT BREAKER HANDLE RATING NOT TO EXCEED 160A PER CIRCUIT CONNECTOR. A SQUARE D UL LISTED SECONDARY SURGE ARRESTER MAY PLUG ON TWO ADJACENT SPACES. ORDER CATALOG NO Q02175SB. MAINS FACTORY SHORT INSTALLED CIRCUIT CATALOG AMPERE BYPASS CURRENT NUMBER SERIES SPACES RATING TYPE RATING 200 HORN 22K QC3040M200SH M01 30 200 NONE 22K QC3040M200S M01 30 KNOCKOUTS SYMBOL CONDUIT SIZE IN MM A B C D E F G H .50 .75 1.00 1.25 1.50 2.00 2.50 3.00 .09 DIA [3] 13 19 25 32 38 51 64 76 HOLE DIA IN MM .87 22 1.12 28 1.37 35 1.75 44 2.00 51 2.50 64 3.00 76 3.62 92 .09 X .33 [3][9]METER COVER LATCH MAXIMUM NUMBER OF SINGLE POLE QO CIRCUITS 40 40 SEAL BRACKEr UTILITY WIREWAY SLOT . INCHES DUAL DIMENSIONS. MILLIMETERS LINE SIDE PHASE & SERVICE NEUTRAL LUGS GROUND LUG AWG/KCMIL AWG #6-350 CU/AL #14-20 cu #12-20 AL #6-350 CU/AL #14-20 cu #12-20 AL SQUARE E:] ,. by Schnelder Electric COMBINATION SERVICE ENTRANCE DEVICES RINGLESS TYPE ALL-IN-ONE QO 30-40 CIRCUIT RAINPROOF NEMA TYPE 3R ENCLOSURE SURFACE MOUNT DWG# PWFDS-SYRS-0049 NO. PWFDS-SYRS-0049 B20-0417 B-1 Panel Schedule Panel ID Panel Location Fed From Amps Single Phase Three Phase Main Breaker Main Lugs Only Fed-thru Lugs Breaker Details Phase TypeGeneral Information Notes Brkr Pole Wire (AWG) Pipe Size VA Voltage Description Ckt Ckt Description Voltage VA Pipe Size Wire Size (AWG) Pole Brkr 120 / 240 120 / 208 277/ 480 Voltage Type 120 / 240 1 120 / 240 3 120 / 240 5 120 / 240 7 120 / 240 9 120 / 240 11 120 / 240 13 120 / 240 15 120 / 240 17 120 / 240 19 120 / 240 21 120 / 240 23 120 / 240 25 120 / 240 27 120 / 240 29 120 / 240 31 120 / 240 33 120 / 240 35 120 / 240 37 120 / 240 39 120 / 240 41 2 120 / 240 4 120 / 240 6 120 / 240 8 120 / 240 10 120 / 240 12 120 / 240 14 120 / 240 16 120 / 240 18 120 / 240 20 120 / 240 22 120 / 240 24 120 / 240 26 120 / 240 28 120 / 240 30 120 / 240 32 120 / 240 34 120 / 240 36 120 / 240 38 120 / 240 40 120 / 240 42 120 / 240 B20-0417 B-1 Additional Address Info: Metering: Meter Clips: 4 Utilities Maximum Contribution to Fault Current: 10000Phase: 1# of Wires: 3 Voltage: 120/240 Temp Service Charge due on First Bill $ 0.00 Provide Minimum Ground Clearance Of: _10_ Ft. From bottom of drip loop at service wire point of attachment _12_ Ft. Over driveway or parking area _16_ Ft. At outer limit of vehicular traffic _2_ Ft. Minimum rigid riser above roof __ Ft. Assessor's Parcel Number: If SDG&E encounters hazardous or toxic material while performing construction of your project, SDG&E will halt work immediately and it will be your responsibility to remove and or clean up all hazardous or toxic material prior to SDG&E continuing construction. SDG&E shall have no liability or obligation whatsoever to cleanup, remove or remediate any hazardous or toxic materials discovered during the course of construction unless it is through negligence of SDG&E. Customer-owned facilities to receive gas service are subject to all applicable local and state of California inspection authority requirements. Building address and/or houseline must be permanently identified prior to meter set. Information on this sheet is void after six (6) months. Keep this notice with building permit. All installations performed under this order must meet SDG&E standards unless a written deviation has been approved. Additional Information: To minimize the electrical outage, you are advised to schedule a morning disconnect with an afternoon reconnect. There is no charge for this service. Before you change out your meter consider (1) SDG&E needs 10 working days advance notice to schedule a crew and (2) SDG&E will not reconnect the service without municipal approval on the new panel. Please contact the City of San Clemente regarding permits and inspections. City inspection should be received prior to 2:00 p.m. on the same day as the disconnection of service to allow the SDG&E crew enough time for reconnection of the service on the same day. Number/Size of Main Switch: 1/200Service Panel Rating: 200 Customer Phone #: 951-600-0654Customer POC: Fran Moran Wanted Date: O/I Job #: 530000187573 ELECTRIC OVERHEAD METER & SERVICE LOCATION Customer Copy Project Title: MCKEAGUE RESIDENCE SOT OH RELOCATE Notification #: 300000331921 Project Address: 31341 YSIDORA ST Customer Type: Residential(1-2 Units) Date Prepared: 04/15/2020 Project City: SAN JUAN CAPISTRANO SDGE Contact: Service Coordinator Contact Info: SERVCIE DESK, 949-361-8066 Planned By: Edward Salsido Phone#: 9493618081 Service Type: OH SERVICE REWIRE/RELOCATION TB: 0952-C7 SERVICE ATTACHMENT POINT AND/OR METER LOCATION: Locate the new point of attachment within 18 inches of the middle of Westerly wall (see sketch). Install rigid riser minimum of 2 feet above roof and meet minimum clearances as noted below. Locate new 200-amp meter panel on the Westerly wall at new location. CALL (949)361-8066 to set up the Disconnect - Crew will Reconnect (same day) "On City Inspection" - Inspection must be received before 2pm. IMPORTANT:"Should the Customer cancel the Crew work less than 24hrs of the scheduled date or onsite, the Requestor will be billed a non-refundable fee to cover the Lost Crew time caused by the lack of adequate notice. These charges must be paid prior to rescheduling the work." SDG&E Application Required-Call: 1-800-411-7343 Municipal Inspection Required By: CITY OF SAN JUAN CAPISTRANO Traffic Control Permit Required Excavation/Encroachment Permits Required By: Right of Way Required Meter height -- 4'0'' min. (3'0" min. for multiple installation) -- 6'3" max. From finish grade to centerline of meter base. Meters are required to be readily accessible 24 hours per day. Meters must be located in a safe area free of any potentially hazardous or dangerous condition. Provide 3-ft. x 3-ft. clear and level working space in front of meter. Where meter room is proposed, contact the planner at the nearest SDG&E office. Meter bases and meter service disconnects must be located at or immediately adjacent to each other and be identified with address and unit number it serves.B20-0417 B-1 Last Revised: March 13, 2015 OH Relocation/31341 Ysidora St. SJ Notification #:3-331921 DATE: 4/16/2020 SDG&E CONTACT: Service Desk 949-361-8066 B20-0417 B-1