B20-0403 - 26341 CALLE ROBERTOCITY OF SAN JUAN CAPISTRANO BUILDING PERMIT ISSUED 06/15/2020 Permit No. B20-0403 DESCRIPTION 20 X 22 Prefab garage ( 440sf) ELECTRICAL PERMIT AMOUNT Pennit Number B20-0403 ISSUED_BY DBI SITE_APN 649-061-08 SITE_LOT_NO 28 SITE_TRACT SITE_SUBDIVISION JOBVALUE $ 5,000 Total Electrical OCCUPANCY_ TYPE PERMIT TYPE ACCESSORY STRUCTURE PLUMBING PERMIT AMOU~T BUILDING _SF 0 NO_STORIES 2 NO UNITS 0 JOB ADDRESS: 26341 CALLE ROBERTO OWNER NAME GOO, DENNIS DK PHONE MAILING ADDRESS 26341 CALLE ROBERTO CITY ,STATE,ZIP SAN JUAN CAPISTRANO, CA 92675 Total Plumbing CONTRACTOR NAME TUFF SHED INC MECHANICAL PERMIT AMOUNT ST LIC # 661664 ST LIC EXPIRE 12/31 /2020 PHONE (303) 474-5524 ADDRESS 1777 S HARRISON STREET CITY, ST, ZIP DENVER, CO 80210 TENANT NAME PHONE# MAILING ADDR CITY, ST, ZIP Total Mechanical ARCH/ENG/DESIGNER MOBILE HOME PERMIT AMOUNT PHONE# MAILING ADDRESS ST LICENSE# CITY, ST, ZIP I have carefully examined the completed pennit application and do hereby certify under penalty of perjury that all infonnation hereon including the declarations are true and correct and I further Total Mobile Home certify and agree ifa pennit is issued: to comply with all City, County, and State laws governing Expiration: Every permit issued by the Building Official under the provisions cf this Code shall expire by building construction, whether specified herein or not. I also agree to save, indemnify and keep hannless the City of San Juan Capistrano against all liabilities, judgment~ costs and expenses limitation and become null and void. If the building or work authorized by such permit is not commenced which may in any way accrue against said City in consequence of the granting of this pem1it. within 180 days from the date rf such permit, or if the building or work authorized by such permit is -~ DicocheA suspended or abandoned at any time after the work is commenced for a period of 180 days. Owner/Cont!actor Arturo Prif!.~_l~-ame IA!~ _J An OSHA penuit is required for excavations over 5'0" deep and demolition or construction of Applicant's strnctw·es over 3 stories in height. f1101raU1m I hereby affinn~that I am licensed under provisions of Chapter 9 of Division 3 of the Business and Professions Code, and my license is in full force and effect. Qwoer/Buildec; I, as owner of the property, or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale. (Sec 7044, Business and Professions the Contractor's License Laws does not apply to and owner of property who builds or improves thereon, who does such work himself or through his employees, provided that such improvements are not intended or offered for sale. If however, the building or unprovement is sold within one year of completion. the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) Qwncr/BuUder-I. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who contracts for such projects with a contractor's) license pursuant to the Contractor's License Law. [..&...,,_ Wi>cl<ec< (11mpegsatjoo-l hereby affinn under penalty of perjury one of the following declarations:! have and will maintain workers' compensation insurance, as required by Section 3700 ofth Labor Code, for the perfonnance of the work for which this pemlit is issued. My workers' compensation insurance carrier and policy number are: Carrier OLD REPUBLIC INSURANCE COMPANY Policy#MWCJ 1257220 (This section needs to be completed if the pennit is for one hundred dollars($ I 00) or less) ___ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date Applicant WARNING·FAJLURE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL. AND SHALL SUBJECT AN EMPLOYER TI CRIMINAL PENALTIES AND CIVIL FINES UPTO ONE HUNDRED TIIOUSDAND DOLLARS($ I 00.000) IN ADDITION TO TIIE COST OF COMPENSATION. DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. FINAL 02/26/21 CITY OF SAN JUAN CAPISTRANO BUILDING PERMIT FEES te: 6/1 s12020 • B20-0403 nt: TUFF SHED INC P one/E-Mail (303) 474-5524 0 ocat1on: 26341 CALLE ROBERTO Account# Type 01-44221 Building Permit 01-44223 Mechanical 01-44224 Plumbing 01-44225 Electrical 01-44221 Mobile Home Permit 01-44222 Grading Permit Fee 01-44231 Grading Plan Check 01-44222 On-Site Residential Permit 01-44231 On-Site Residential Plan Check Subtotal 01-44230 Bond Processing 01-44230 Building Plan Check 01-44230 Additional Plan Check 01-44230 Digital Record Fee ($1.00 per sheet) 01-44221 C & D Administrative Fee 01-44221 Special lnspection-Reinspection 01-44222 On-Site Commercial/Tract Permit Fee 01-44231 On-Site Commercial/Tract Plan Check Fee 01-44214 Geotechnical Soils Plan Re1.1ew 10-44320 Ordinance 211 10-42510 Ordinance 364 01-45354 Copies @ .20 Each 90-23331 SMIP Fee 33-44370 H.0.P.E. Fee (Housing in Lieu) Other Fees rcA Fees I Date Received HOA Approval I Date Received !School Fees I Date Received I Engineenng t=ees I Date Received Water Di1.1sion Fees Date Received 01-44221 Title 24 Energy Pro1.1sion (20% Permit Subtotal & Bldg Plan Check)) 01-44221 Title 24 ADA Fee (10% Permit Subtotal & Bldg Plan Check) 01-44240 NPDES Permit Fee (10% Permit Subtotal) 90-23000 Refundable Bond/Deposit Posted by Owner Contractor 90-23000 Refundable Bond/Deposit Posted by Owner Contractor TOTAL FEES PAYABLE TO CITY OF SAN JUAN CAPISTRANO Cost $ 148.86 $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 148.86 $ 0.00 $ 0.00 $ 0.00 $ 28.50 $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 0.65 $ 0.00 $ 413.51 $ 0.00 $ 0.00 $ 14.89 Type $ 0.00 Type $ 606.41 Receipt# -=-7=59'-'4..::..0 __ Date: 6/15/2020 Cashier: _____________ _ 1 B20 0403 Site: Project: 20.0' x 22.0' Store: 1281 N. Sunshine Way Anaheim, CA 92806 Engineer: Tuff Shed Inc. 1777 South Harrison St., Ste. 600 Denver, CO 80210 Date: Structural Calculations for April 2, 2020 Garage Inv. No. 1462144 Dennis Goo 26341 Calle Roberto San Juan Capistrano, CA 92675 140 - Anaheim Timothy Cahalan, P.E. (303) 753-8833 ext. 96319 TCahalan@tuffshed.com Page 1 of 8 Building Code: 2019 CBC Seismic Design Category: D Basic Wind Speed: 100 mph Wind Exposure: C Width: 22.0 ft. Length: 20.0 ft. Side Wall Height: 8.09 ft. Stud Size: 2x4 Stud Spacing: 16 in. o.c. Wall Sheathing: 7/16" OSB Roof Sheathing: 7/16" OSB Wall Wood Species & Grade: HF Stud Wall "A" Overhang: 12.0 in. Wall "B" Overhang: 12.0 in. Wall "C" Overhang: 12.0 in. Wall "D" Overhang: 12.0 in. Foundation: Concrete - Monolithic Foundation with Curb Anchor: J- or L-Bolts Anchor Bolt Diameter: .63 in. Span: 22.0 ft. Left Overhang: 12.0 in. Right Overhang: 12.0 in. Spacing: 24 in. o.c. Pitch: 5./12 Lumber: HF #2 Roofing: Composition Shingles Top Chord Live/Snow Load: 25 psf Top Chord Dead Load: 10 psf Bottom Chord Live Load: 0 psf Bottom Chord Dead Load: 10 psf Risk Category: II-Regular Building Specifications Trusses DESIGN CRITERIA Page 2 of 8 Page 3 of 8 Top Chord Live/Snow Load: 25 psf Top Chord Dead Load: 10 psf Tributary Width= 2.0 ft. Bottom Chord Live Load: 0 psf Height of wall above Header= 4.50 ft. Bottom Chord Dead Load: 10 psf Moment= 55,131 in.-lbs. Reaction= 1,114 lbs. Header Size: 2x12 Header Size: 1¾x7¼ LVL Number of Headers: 2 Number of Headers: 2 Header depth= 11.25 in.Header depth= 7.25 in. Total header width= 3.0 in.Total header width= 3.50 in. Header span= 16.50 ft.Fb=850 psi Header span= 16.50 ft.Fb=2600 psi Ft=525 psi Ft=1555 psi Fv=150 psi Fv=285 psi Sx=63.28 cu.in.FcP=405 psi Sx=30.66 cu.in.FcP=750 psi F'b=878 psi Fc=1300 psi F'b=2847 psi Fc=2510 psi fb=871 psi E= 1,300,000 psi fb=1798 psi E= 1,900,000 psi Emin=470,000 psi Emin=965,710 psi Good/No Good?O.K.Good/No Good?O.K. CD=1.15 Duration CD=1.15 Duration CM=1.00 Wet Service CM=1.00 Wet Service F'v=173 psi Ct=1.00 Temperature F'v=328 psi Ct=1.00 Temperature fv=50 psi CL=0.90 Beam Stability fv=66 psi CL=0.95 Beam Stability Good/No Good?O.K.CF=1.00 Size Good/No Good?O.K.CF=1.00 Size Cfu=1.00 Flat Use Cfu=1.00 Flat Use Ci=1.00 Incising Ci=1.00 Incising E'= 1,300,000 psi Cr=1.00 Repetitive Member E'= 1,900,000 psi Cr=1.00 Repetitive Member I= 355.957 Cf=1.00 Form I= 111.148 Cf=1.00 Form Deflection Ratio= L/180 TL (L/x) L/240 LL(L/x) Deflection Ratio= L/180 TL(L/x) L/240 LL(L/x) Allowable Deflection= 1.10 in. .83 in. Allowable Deflection= 1.10 in. 1.10 in.Δ= .49 in. .34 in.Δ= 1.07 in. .75 in. Good/No Good?O.K. O.K.Good/No Good?O.K. O.K. Top Chord Live/Snow Load: 25 psf Top Chord Dead Load: 10 psf Tributary Width= 12.0 ft. Bottom Chord Live Load: 0 psf Height of wall above Header= 1.50 ft. Bottom Chord Dead Load: 10 psf Moment= 8,793 in.-lbs.Reaction= 902 lbs. Header Size: 2x4 Header Size: 1¾x3½ LVL Number of Headers: 2 Number of Headers: 2 Header depth= 3.50 in.Header depth= 3.50 in. Total header width= 3.0 in.Total header width= 3.50 in. Header span= 3.25 ft.Fb=850 psi Header span= 3.25 ft.Fb=2600 psi Ft=525 psi Ft=1555 psi Fv=150 psi Fv=285 psi Sx=6.13 cu.in.FcP=405 psi Sx=7.15 cu.in.FcP=750 psi F'b=1460 psi Fc=1300 psi F'b=2981 psi Fc=2510 psi fb=1436 psi E= 1,300,000 psi fb=1231 psi E= 1,900,000 psi Emin=470,000 psi Emin=965,710 psi Good/No Good?O.K.Good/No Good?O.K. CD=1.15 Duration CD=1.15 Duration CM=1.00 Wet Service CM=1.00 Wet Service F'v=173 psi Ct=1.00 Temperature F'v=328 psi Ct=1.00 Temperature fv=129 psi CL=1.00 Beam Stability fv=110 psi CL=1.00 Beam Stability Good/No Good?O.K.CF=1.50 Size Good/No Good?O.K.CF=1.00 Size Cfu=1.00 Flat Use Cfu=1.00 Flat Use Ci=1.00 Incising Ci=1.00 Incising E'= 1,300,000 psi Cr=1.00 Repetitive Member E'= 1,900,000 psi Cr=1.00 Repetitive Member I= 10.71875 Cf=1.00 Form I= 12.50520833 Cf=1.00 Form Deflection Ratio= L/180 TL (L/x) L/240 LL(L/x) Deflection Ratio= L/180 TL(L/x) L/240 LL(L/x) Allowable Deflection= .22 in. .16 in. Allowable Deflection= .22 in. .22 in. Δ= .10 in. .06 in.Δ= .06 in. .03 in. Good/No Good?O.K. O.K.Good/No Good?O.K. O.K. Header: Wall A, Hdr 1 Lumber HF #2 Lumber LVL 2600Fb Lumber Deflection Deflection Lumber HF #2 LVL 2600Fb Bending Header: Wall B, Hdr 2 Bending Bending Shear Shear Lumber FactorsLumber Factors OR Bending OR Lumber Factors Lumber Factors Deflection Deflection Shear Shear Page 4 of 8 Trimmer for:Trimmer for: Fb= 675 psi Fb= 675 psi Load= 1,114 lbs. Ft= 400 psi Load= 902 lbs. Ft= 400 psi width= 3.50 in. Fv= 150 psi width= 3.50 in. Fv= 150 psi thickness= 1.50 in. FcP= 405 psi thickness= 1.50 in. FcP= 405 psi No. of members= 1 Fc= 800 psi No. of members= 1 Fc= 800 psi Unbraced Length(x)(width)= 90.0 in. Emin= 440,000 psi Unbraced Length(x)(width)= 90.0 in. Emin= 440,000 psi Unbraced Length(y)(thickness)= 6.0 in. Unbraced Length(y)(thickness)= 6.0 in. Effective Length factor, Ke(x)=1 Effective Length factor, Ke(x)=1 Effective Length factor, Ke(y)=1 CD= 1.15 Duration Effective Length factor, Ke(y)=1 CD= 1.15 Duration CM= 1.00 Wet Service CM= 1.00 Wet Service c= 0.8 Ct= 1.00 Temperature c= 0.8 Ct= 1.00 Temperature A= 5.25 sq.in. CL= 1.00 Beam Stability A= 5.25 sq.in. CL= 1.00 Beam Stability (l/d)x= 25.71 CF= 1.05 Size (l/d)x= 25.71 CF= 1.05 Size (l/d)y= 4.00 Cfu= 1.00 Flat Use (l/d)y= 4.00 Cfu= 1.00 Flat Use E'min= 440,000 psi Ci= 1.00 Incising E'min= 440,000 psi Ci= 1.00 Incising Cr= 1.00 Repetitive Member Cr= 1.00 Repetitive Member Cf= 1.00 Form Cf= 1.00 Form CT= 1.00 Buckling Stiffness CT= 1.00 Buckling Stiffness FcE= 22605.00 FcE= 546.99 FcE= 22605.00 FcE= 546.99 F*c= 966.00 F*c= 966.00 F*c= 966.00 F*c= 966.00 FcE/F*c= 23.40 FcE/F*c= 0.57 FcE/F*c= 23.40 FcE/F*c= 0.57 1+FcE/F*c/2c= 15.25 1+FcE/F*c/2c= 0.98 1+FcE/F*c/2c= 15.25 1+FcE/F*c/2c= 0.98 CP= 0.99 CP= 0.48 CP= 0.99 CP= 0.48 F'c= 957.53 F'c= 462.19 F'c= 957.53 F'c= 462.19 Pallowable= 5,027 lbs. Pallowable= 2,426 lbs. Pallowable= 5,027 lbs. Pallowable= 2,426 lbs. Good/No Good?O.K.Good/No Good?O.K.Good/No Good?O.K.Good/No Good?O.K. Strong Axis Calculations (x) Lumber Factors Header: Wall A, Hdr 1 HF Stud Weak Axis Calculations(y) Header: Wall B, Hdr 2 HF Stud Lumber Factors Weak Axis Calculations(y) Strong Axis Calculations (x) Page 5 of 8 Building Code: 2019 CBC Seismic Design Classification: D Site Class: D Ss=1.191 Figure 22-1 F= 1 Section 12.14.8.1 Fa=1.2 Table 11.4-1 R= 6.5 Table 12.14-1 I= 1 Table 11.5-1 ρ=1.30 W= 13,078 lbs. S= lbs. 20% of snow weight (if applicable) SDS=0.95 Eq. 12.14-11 V= 2,492 lbs. Eq. 12.14-11 SEISMIC CALCULATIONS Page 6 of 8 Wind Speed, vASD:77 mph Basic Wind Speed, V: 100 mph Wind Exposure: C Risk Category: II-Regular Roof Angle= 22.62 Gable Wall Span= 22.0 ft. Longitude Wall Span= 20.0 ft. Mean Roof Height= 12.67 ft. Enclosure Classification: Enclosed Section 26.10 Kzt=1 Section 26.8 Kz=0.85 Table 26.10-1 Kd=0.85 Table 26.6-1 Ke=1 Table 26.9-1 GCpi=±0.18 Table 26.13-1 qh=18.50 psf Eq. 26.10-1 12345 61E2E 3E 4E Load Case A 0.54 -0.45 -0.47 -0.41 N/A N/A 0.77 -0.72 -0.65 -0.60 Load Case B -0.45 -0.69 -0.37 -0.45 0.40 -0.29 -0.48 -1.07 -0.53 -0.48 Load Case A (-GCpi)6.62 psf -11.73 psf -11.97 psf -10.99 psf N/A N/A 10.93 psf -16.63 psf -15.32 psf -14.39 psf Load Case A (+GCpi)13.28 psf -5.07 psf -5.31 psf -4.33 psf N/A N/A 17.59 psf -9.97 psf -8.66 psf -7.73 psf Load Case B (-GCpi)-11.65 psf -16.09 psf -10.17 psf -11.65 psf 4.07 psf -8.69 psf -12.21 psf -23.12 psf -13.13 psf -12.21 psf Load Case B (+GCpi)-4.99 psf -9.43 psf -3.51 psf -4.99 psf 10.73 psf -2.03 psf -5.55 psf -16.46 psf -6.47 psf -5.55 psf max. pL=17.59 psf Side Wall, maximum wind pressure max. pT=16.0 psf Gable End Wall, maximum wind pressure max. pwall=17.59 psf max. proof=-23.12 psf VL=2,231 lbs. Max. Longitudinal Shear VT=2,230 lbs. Max. Transversial Shear Max. uplift pressure= -12,207 lbs. Max. uplift pressure on the building due to wind on roof Length (for shear) Wall A: 6.0 ft. Wall B: 17.0 ft. Wall C: 22.0 ft. Wall D: 20.0 ft. Sheathing* Nail Size Edge Nailing Boundary Nailing vallow HF/SPF Factor Roof 7/16" OSB 8d 6 in. o.c. 12 in. o.c. v= 180.0 plf 167.4 plf 0.93 Wall 7/16" OSB 8d 6 in. o.c. 12 in. o.c. v= 265.0 plf 246.5 plf 0.93 Wall 7/16" OSB 8d 4 in. o.c. 12 in. o.c. v= 335.0 plf 311.6 plf 0.93 Wind Seismic vallow 2bs/h edge nailing Wall A: 223.0 plf Wall A: 145.4 plf 231.1 plf C0=1.00 0.74 3" o.c. Wall B: 78.7 plf Wall B: 51.3 plf 202.6 plf C0=0.82 1.00 6" o.c. Wall C: 60.8 plf Wall C: 39.6 plf 246.5 plf C0=1.00 1.00 6" o.c. Wall D: 66.9 plf Wall D: 43.6 plf 246.5 plf C0=1.00 1.00 6" o.c. Roof= 66.9 plf 167.4 plf Wind Calculations (MWFRS) Diaphragm Calculations ASCE 7-16 Chapt. 28 Part 1 GCpfp*Must be Rated sheathing Page 7 of 8 Fb=1500 psf Min. allowable bearing pressure Foundation Stem above grade= 8.0 in. Height of foundation from the top of the grade to the top of the foundation/stemwall Foundation Depth= 12.0 in. Depth of the foundation from the top of the grade to the bottom of the footing Pmax=620.9 plf Max. load per foot of wall bftg=4.97 in. min. required footing width PLmax=1,646 lbs. Maximum point load bftg=158.03 sq.in. Min. required footing area Rectangular pad= 3.95 in. min. required footing width Min. No. anchor bolts= 2 Min. No. anchor bolts= 3 Width= 6.0 ft.Width= 17.0 ft. Height= 8.09 ft.Height= 8.09 ft. Pwind=2,230 lbs.Pwind=2,231 lbs. Pseismic=1,246 lbs.Pseismic=1,246 lbs. Wall Weight= 315.24 lbs.Wall Weight= 969.18 lbs. Upliftwind=1,646.14 lbs.Provide SSTD16 anchor bolts/ HDU2 holddown Upliftwind=152.29 lbs. Upliftseismic=1,018.45 lbs.at corners and each side of door.Upliftseismic=.0 lbs. Allowable Service, wind: 1.50 N.G. Holddowns required.Allowable Service, wind: 0.58 ok. No additional holddowns required. Allowable Service, seismic: 0.60 ok. No additional holddowns required.Allowable Service, seismic: 0.22 ok. No additional holddowns required. Min. No. anchor bolts= 3 Min. No. anchor bolts= 3 Width= 22.0 ft.Width= 20.0 ft. Height= 8.09 ft.Height= 8.09 ft. Pwind=2,230 lbs.Pwind=2,231 lbs. Pseismic=1,246 lbs.Pseismic=1,246 lbs. Wall Weight= 1,091.88 lbs. Wall Weight= 1,114.80 lbs. Upliftwind=.0 lbs.Upliftwind=.0 lbs. Upliftseismic=.0 lbs.Upliftseismic=.0 lbs. Allowable Service, wind: 0.57 ok. No additional holddowns required.Allowable Service, wind: 0.57 ok. No additional holddowns required. Allowable Service, seismic: 0.22 ok. No additional holddowns required.Allowable Service, seismic: 0.22 ok. No additional holddowns required. Wind uplift= -12,207.36 lbs. Min. building weight= 7,846.68 lbs. Additional min. dead load= .0 lbs. additional dead load due to steel floor, wood base, or other permanent loads,if any, (not including foundation) Net uplift= -4,360.68 lbs. Total no. of anchor bolts (min.)= 11 (Does not include additional holddowns for overturning of the walls.) Anchor bolt uplift= 32,159.53 lbs. OK. No additional anchors needed. Building Uplift Foundation Calculations Overturning Calculations Wall A Wall B Wall C Wall D Page 8 of 8 Axial Load Stud Spacing= 16 in. o.c.Fb=675 psi Max. Load on wall= 620.9 plf Ft=400 psi Fv=150 psi depth= 3.50 in.FcP=405 psi width= 1.50 in.Fc=800 psi No. of members= 1 Emin=440,000 psi Length (depth)= 92.58 in. unbraced length (depth)(x)(in.) E= 1,200,000 psi Length (width)= 12.0 in. unbraced length (width)(y)(in.) Ke(x)=1 effective length factor (x)CD=1.15 Duration for gravity load Ke(y)=1 effective length factor (y)CM=1.00 Wet Service KcE=0.3 Ct=1.00 Temperature c= 0.8 CL=1.00 Beam Stability CF=1.05 Size for Fc Load= 828 lbs. Load per stud Cfu=1.00 Flat Use Ci=1.00 Incising A= 5.25 sq.in.Cr=1.15 Repetitive Member (l/d)x=26.45 Cf=1.00 Form (l/d)y=8.00 CT=1.00 Buckling Stiffness (NDS 4.4.2) E'min=440,000 psi CF=1.10 Size for Fb CD=1.60 Duration for lateral load Cr=1.50 Repetitive Member (wind) FcE=5651.25 FcE=516.92 F*c=966.00 F*c=966.00 FcE/F*c=5.85 FcE/F*c=0.54 1+FcE/F*c/2c=4.28 1+FcE/F*c/2c=0.96 CP=0.96 CP=0.46 F'c=929.41 F'c=442.24 Pallowable=4,879 lbs.Pallowable=2,322 lbs. Good/No Good?O.K.Good/No Good?O.K. Wind Load Wind load per stud= 23.5 plf Moment= 2,094 in.-lbs. Reaction= 90 lbs. Header depth= 3.50 in. Total header width= 1.50 in. Header span= 8.0 ft. Sx=3.06 cu.in. F'b=1782 psi fb=684 psi Good/No Good?O.K. F'v=240 psi fv=26 psi Good/No Good?O.K. Combined Bending and Axial Loading F'c=615.29 combine allowable compressive stress fc=70 psi combine compressive stress Combined stress index= 0.46 Good/No Good?O.K. Bearing Wall Calculations Bending Shear Lumber HF Stud Lumber Factors Weak Axis Calculations(y) Strong Axis Calculations (x) BUILDING DEPARTMENT REVISION 32400 Paseo Adelanto San Juan Capistrano, CA 92675 949-493-1171 CONTRACTOR OF RECORD Tv--~ sheA CONTACT NAME: A--r--tUyt) Di C,Olk\tlA. CONTACT PHONE# ( 1(a0 ) 9--l~-'5l9t5 PERMIT NUMBER JOB ADDRESS d-lP3YI [i;.!le R,,_1...,ir....-r, DEPARTMENT APPROVAL REQUIRED: I REV# I EMAIL ADDRESS PLANNING: t( YES NO Nli co0heoi.@, tuftskeJ. COW) INSTRUCTIONS: 1 . "CLOUD" the proposed changes on the drawings. 2 . Note the page number(s) on which the revision(s) occur. 3 . Provide description of proposed changes. DESCRIPTION OF PROPOSED CHANGES: PG# ENGINEERING: Cl'.. YES NO WATER: YES NO [I] 1. Plo.n:> -P"Jt J: t r1ASS 1-fto..OOo 2. :fla-\'\S P4 t 3: JY\I\SX-5 3. NtW TY-\ASS C£t /cs Os.-------------- DATE BUILDING REVISION FEE: ESTIMATED REVIEW TIME: $86.93/HOUR -1 HOUR MINIMUM -Per table 3.A.1 HOURS I FOR OFFICE USE ONLY _ APPROVED BY:__________ DATE: _________ _ October 23, 2020 Tuff Shed Inc. 1281 Sunshine Way Anaheim, CA 92806 Re: Anchor Bolt Dennis Goo (EP-2624) 26341 Calle Roberto San Juan Capistrano, CA 92675 To Whom It May Concern: This is in response to the building department inspection comments regarding the missing anchor bolts. It is acceptable to use 5/8” dia x 8” long Titen HD concrete screw anchor or equal with a minimum embedment into the concrete of 5½” in leu of the cast in place anchors shown in detail 03S3. Anchors shall be installed according to the manufactures recommendations. If you have any questions, feel free to contact me. Sincerely, Timothy D Cahalan, P.E. tcahalan@tuffshed.com (720) 673-4779 ext. 96319 10/23/2020