Loading...
21-0216_ONESOURCE_Purchase Agreement Page 1 of 12 61147.02100\24471712.1 CITY OF SAN JUAN CAPISTRANO EQUIPMENT PURCHASE AGREEMENT This Equipment Purchase Agreement (“Agreement”) is entered into this 16th day of February, 2021, by and between the City of San Juan Capistrano, a municipal corporation organized and operating under the laws of the State of California with its principal place of business at a municipal corporation organized under the laws of the State of California with its principal place of business at 32400 Paseo Adelanto, San Juan Capistrano, California 92675 (“City”), and OneSource, a Corporation with its principal place of business at Fullerton, CA (“Contractor”). City and Contractor are sometimes individually referred to as “Party” and collectively as “Parties” in this Agreement. Section 1. DEFINITIONS. A. “Equipment” means all machinery, equipment, items, parts, materials, labor or other services, including design, engineering and installation services, provided by Contractor as specified in Exhibit “A,” attached hereto and incorporated herein by reference. B. “Delivery Date(s)” means that date or dates upon which the Equipment is to be delivered to City, ready for approval, testing and/or use as specified in Exhibit “A.” Section 2. MATERIALS AND WORKMANSHIP. When Exhibit “A” specifies machinery, equipment or material by manufacturer, model or trade name, no substitution will be made without City’s written approval. Machinery, equipment or material installed in the Equipment without the approval required by this Section 2 will be deemed to be defective material for purposes of Section 4. Where machinery, equipment or materials are referred to in Exhibit “A” as equal to any particular standard, City will decide the question of equality. When requested by City, Contractor will furnish City with the name of the manufacturer, the performance capabilities and other pertinent information necessary to properly determine the quality and suitability of any machines, equipment and material to be incorporated in the Equipment. Material samples will be submitted at City’s request. Section 3. INSPECTIONS AND TESTS. City shall have the right to inspect and/or test the Equipment prior to acceptance. If upon inspection or testing the Equipment or any portion thereof are found to be nonconforming, unsatisfactory, defective, of inferior quality or workmanship, or fail to meet any requirements or specifications contained in Exhibit “A,” then without prejudice to any other rights or remedies, City may reject the Equipment or exercise any of its rights under Section 4.C. The inspection, failure to make inspection, acceptance of goods, or payment for goods shall not impair City’s right to reject nonconforming goods, irrespective of City’s failure to notify Contractor of a rejection of nonconforming goods or revocation of acceptance thereof or to specify with particularity any defect in nonconforming goods after rejection or acceptance thereof. Page 2 of 12 61147.02100\24471712.1 Section 4. WARRANTY. A. Contractor warrants that the Equipment will be of merchantable quality and free from defects in design, engineering, material and workmanship for a period of two (2) years, or such longer period as provided by a manufacturer’s warranty or as agreed to by Contractor and City, from the date of final written acceptance of the Equipment by City as required for final payment under Section 7. Contractor further warrants that any services provided in connection with the Equipment will be performed in a professional and workmanlike manner and in accordance with the highest industry standards. B. Contractor further warrants that all machinery, equipment or process included in the Equipment will meet the performance requirements and specifications specified in Exhibit “A” and shall be fit for the purpose intended. City’s inspection, testing, approval or acceptance of any such machinery, equipment or process will not relieve Contractor of its obligations under this Section 4.B. C. For any breach of the warranties contained in Section 4.A and Section 4.B, Contractor will, immediately after receiving notice from City, at the option of City, and at Contractor’s own expense and without cost to City: 1. Repair the defective Equipment; 2. Replace the defective Equipment with conforming Equipment, F.O.B. City’s plant, office or other location of City where the Equipment was originally performed or delivered; or 3. Repay to City the purchase price of the defective Equipment. If City selects repair or replacement, any defects will be remedied without cost to City, including but not limited to, the costs of removal, repair and replacement of the defective Equipment, and reinstallation of new Equipment. All such defective Equipment that is so remedied will be similarly warranted as stated above. In addition, Contractor will repair or replace other items of the Equipment which may have been damaged by such defects or the repairing of the same, all at its own expense and without cost to City. D. Contractor also warrants that the Equipment is free and clear of all liens and encumbrances whatsoever, that Contractor has a good and marketable title to same, and that Contractor owns or has a valid license for all of the proprietary technology and intellectual property incorporated within the Equipment. Contractor agrees to indemnify, defend and hold City harmless against any and all third party claims resulting from the breach or inaccuracy of any of the foregoing warranties. E. In the event of a breach by Contractor of its obligations under this Section 4, City will not be limited to the remedies set forth in this Section 4, but will have all the rights and remedies permitted by applicable law, including without limitation, all of the rights and remedies afforded to City under the California Commercial Code. Page 3 of 12 61147.02100\24471712.1 Section 5. PRICES. Unless expressly provided otherwise, all prices and fees specified in Exhibit “A,” attached hereto and incorporated herein by reference, are firm and shall not be subject to change without the written approval of City. No extra charges of any kind will be allowed unless specifically agreed to in writing by City’s authorized representative. The total price shall include (i) all federal, state and local, use, excise, privilege, payroll, occupational and other taxes applicable to the Equipment furnished to City hereunder; and (ii) all charges for packing, freight and transportation to destination. Section 6. CHANGES. City, at any time, by a written order, and without notice to any surety, may make changes in the Equipment, including but not limited to, City’s requirements and specifications. If such changes affect the cost of the Equipment or time required for its performance, an equitable adjustment will be made in the price or time for performance or both. Any change in the price necessitated by such change will be agreed upon between City and Contractor and such change will be authorized by a change order document signed by City and accepted by Contractor. Section 7. PAYMENTS. A. Terms of payment, are net thirty (30) days, less any applicable retention, after receipt of invoice, or completion of applicable Progress Milestones. Final payment shall be made by City after Contractor has satisfied all contractual requirements. Payment of invoices shall not constitute acceptance of Equipment. B.If Progress Milestones have been specified Exhibit “A,” then payments for the Equipment will be made as the requirements of such Progress Milestones are met. Progress payments for the Equipment will be made by City upon proper application by Contractor during the progress of the Equipment and according to the terms of payment as specified in Exhibit “A.” Contractor’s progress billing invoice will include progress payments due for the original scope of work and changes. Each “Item for Payment” shown in Exhibit “A” and each change order will be itemized on the invoice. Invoices for cost plus work, whether part of Exhibit “A” or a change order, must have subcontractor and/or supplier invoices attached to Contractor’s invoice. Other format and support documents for invoices will be determined by City in advance of the first invoice cycle. C. Payments otherwise due may be withheld by City on account of defective Equipment not remedied, liens or other claims filed, reasonable evidence indicating probable filing of liens or other claims, failure of Contractor to make payments properly to its subcontractors or for material or labor, the failure of Contractor to perform any of its other obligations under the Agreement, or to protect City against any liability arising out of Contractor’s failure to pay or discharge taxes or other obligation s. If the causes for which payment is withheld are removed, the withheld payments will be made promptly. If the said causes are not removed within a reasonable period after written notice, City may remove them at Contractor’s expense. Page 4 of 12 61147.02100\24471712.1 D. Payment of the final Progress Milestone payment or any retention will be made by City upon: 1. Submission of an invoice for satisfactory completion of the requirements of a Progress Milestone as defined in Exhibit “A” and in the amount associated with the Progress Milestone; 2. Written acceptance of the Equipment by City; 3. Delivery of all drawings and specifications, if required by City; 4. Delivery of executed full releases of any and all liens arising out of this Agreement; and 5. Delivery of an affidavit listing all persons who might otherwise be entitled to file, claim or maintain a lien of any kind or character, and containing an averment that all of the said persons have been paid in full. If any person refuses to furnish an actual release or receipt in full, Contractor may furnish a bond satisfactory to City to indemnify City against any claim or lien at no cost to City. E. Acceptance by Contractor of payment of the final Progress Milestone payment pursuant to Section 7.D will constitute a waiver, release and discharge of any and all claims and demands of any kind or character which Contractor then has, or can subsequently acquire against City, its successors and assigns, for or on account of any matter or thing arising out of, or in any manner connected with, the performance of this Agreement. However, payment for the final Progress Milestone by City will not constitute a waiver, release or discharge of any claims or demands which City then has, or can subsequently acquire, against Contractor, its successors and assigns, for or on account of any matter or thing arising out of, or in any manner connected with, the performance of this Agreement. Section 8. SCHEDULE FOR DELIVERY. A.The time of Contractor’s performance is of the essence for this Agreement . The Equipment will be delivered in accordance with the schedule set forth in Exhibit “A.” Contractor must immediately notify City in writing any time delivery is behind schedule or may not be completed on schedule. In addition to any other rights City may have under this Agreement or at law, Contractor shall pay City the sum of $10 per item of Equipment for each calendar day for which the item of Equipment is unavailable beyond the scheduled delivery date(s) specified in Exhibit “A.” B. In the event that the Equipment is part of a larger project or projects that require the coordination of multiple contractors or suppliers, then Contractor will fully cooperate in scheduling the delivery so that City can maximize the efficient completion of such project(s). Page 5 of 12 61147.02100\24471712.1 Section 9. TAXES. A. Contractor agrees to timely pay all use tax (including any value added or gross receipts tax imposed similar to a sales and use tax) imposed by any federal, state or local taxing authority on the ultimate purchase price of the Equipment provided under this Agreement. B. Contractor will withhold, and require its subcontractors, where applicable, to withhold all required taxes and contributions of any federal, state or local taxing authority which is measured by wages, salaries or other remuneration of its employees or the employees of its subcontractors. Contractor will deposit, or cause to be deposited, in a timely manner with the appropriate taxing authorities all amounts required to be withheld. C. All other taxes, however denominated or measured, imposed upon the price of the Equipment provided hereunder, will be the responsibility of Contractor. In addition, all taxes assessed by any taxing jurisdiction based on Contractor property used or consumed in the provision of the Equipment such as and including ad valorem, use, personal property and inventory taxes will be the responsibility of Contractor. D. Contractor will, upon written request, submit to City written evidence of any filings or payments of all taxes required to be paid by Contractor hereunder. Section 10. INDEPENDENT CONTRACTOR. Contractor enters into this Agreement as an independent contractor and not as an employee of City. Contractor shall have no power or authority by this Agreement to bind City in any respect. Nothing in this Agreement shall be construed to be inconsistent with this relationship or status. All employees, agents, contractors or subcontractors hired or retained by the Contractor are employees, agents, contractors or subcontractors of the Contractor and not of City. City shall not be obligated in any way to pay any wage claims or other claims made against Contractor by any such employees, agents, contractors or subcontractors or any other person resulting from performance of this Agreement. Section 11. SUBCONTRACTS. Unless otherwise specified, Contractor must obtain City’s written permission before subcontracting any portion of the Equipment. Except for the insurance requirements in Section 13.A, all subcontracts and orders for the purchase or rental of supplies, materials or equipment, or any other part of the Equipment, will require that the subcontractor be bound by and subject to all of the terms and conditions of the Agreement. No subcontract or order will relieve Contractor from its obligations to City, including, but not limited to Contractor’s insurance and indemnification obligations. No subcontract or order will bind City. Section 12. TITLE AND RISK OF LOSS. Unless otherwise agreed, City will have title to, and risk of loss of, all completed and partially completed portions of the Equipment upon delivery, as well as materials delivered to and stored on City property which are intended to become a part of the Equipment. However, Page 6 of 12 61147.02100\24471712.1 Contractor will be liable for any loss or damage to the Equipment and/or the materials caused by Contractor or its subcontractors, their agents or employees, and Contractor will replace or repair said Equipment or materials at its own cost to the complete satisfaction of City. Notwithstanding the foregoing, in the event that the City has paid Contractor for all or a portion of the Equipment which remains in the possession of Contractor, then City shall have title to, and the right to take possession of, such Equipment at any time following payment therefor. Risk of loss for any Equipment which remains in the possession of Contractor shall remain with Contractor until such Equipment has been delivered or City has taken possession thereof. Contractor will have risk of loss or damage to Contractor’s property used in the construction of the Equipment but which does not become a part of the Equipment. Section 13. INDEMNIFICATION. A. Contractor shall defend, indemnify and hold the City, its elected officials, officers, employees, volunteers and agents free and harmless from any and all claims, demands, causes of action, costs, expenses, liability, loss, damage or injury, in law or equity, to property or persons, including wrongful death, in any manner arising out of or incident to any alleged acts, omissions, negligence or willful misconduct of Contractor, its officials, officers, employees, agents, subcontractors and subconsultants arising out of or in connection with the Equipment or the performance of this Agreement, including without limitation the payment of all consequential damages and attorneys’ fees and other related costs and expenses except such loss or damage which was caused by the sole negligence or willful misconduct of the City. B. Contractor’s defense obligation for any and all such aforesaid suits, actions or other legal proceedings of every kind that may be brought or instituted against the City, its directors, officials, officers, employees, agents or volunteers shall be at Contractor’s own cost, expense and risk. Contractor shall pay and satisfy any judgment, award or decree that may be rendered against City or its elected officials, officers, employees, agents or volunteers, in any such suit, action or other legal proceeding. Contractor shall reimburse City and its elected officials, officers, employees, agents and/or volunteers, for any and all legal expenses and costs incurred by each of them in connection therewith or in enforcing the indemnity herein provided. C.Contractor’s obligation to indemnify shall not be restricted to insurance proceeds, if any, received by the City, its elected officials, officers, employees, agents or volunteers. Section 14. INSURANCE. A. General. Contractor shall take out and maintain: 1. Commercial General Liability Insurance, of at least $1,000,000 per occurrence/ $2,000,000 aggregate for bodily injury, personal injury and property damage, at least as broad as Insurance Services Office Commercial General Liability most recent Occurrence Form CG 00 01; 2. Automobile Liability Insurance for bodily injury and property damage including coverage for owned, non-owned and hired vehicles, of at least $1,000,000 per Page 7 of 12 61147.02100\24471712.1 accident for bodily injury and property damage, at least as broad as most recent Insurance Services Office Form Number CA 00 01 covering automobile liability, Code 1 (any auto); 3.Workers’ Compensation in compliance with applicable statutory requirements and Employer's Liability Coverage of at least $1,000,000 per occurrence; and 4. Pollution Liability Insurance of at least $1,000,000 per occurrence and $2,000,000 aggregate shall be provided by the Contractor if transporting hazardous materials. 5. If Contractor is also the manufacturer of any equipment included in the Equipment, Contractor shall carry Product Liability and/or Errors and Omissions Insurance which covers said equipment with limits of not less than $1,000,000. B. Additional Insured; Primary; Waiver of Subrogation; No Limitation on Coverage. The policies required under this Section shall give City, its elected officials, officers, employees, agents or volunteers additional insured status. Such policies shall contain a provision stating that Contractor’s policy is primary insurance and that any insurance, self-insurance or other coverage maintained by the City or any additional insureds shall not be called upon to contribute to any loss, and shall contain or be endorsed with a waiver of subrogation in favor of the City, its officials, officers, employees, agents, and volunteers. The limits set forth herein shall apply separately to each insured against whom claims are made or suits are brought, except with respect to the limits of liability. Requirements of specific coverage or limits contained in this section are not intended as a limitation on coverage, limits, or other requirement, or a waiver of any coverage normally provided by any insurance. Any available coverage shall be provided to the parties required to be named as additional insured pursuant to this Agreement. C. Insurance Carrier. All insurance required under this Section is to be placed with insurers with a current A.M. Best’s rating no less than A-:VII, licensed to do business in California, and satisfactory to the City. D. Evidence of Insurance. Contractor shall furnish City with original certificates of insurance and endorsements effecting coverage required by the Agreement. The certificates and endorsements for each insurance policy shall be signed by a person authorized by that insurer to bind coverage on its behalf, and shall be on forms supplied or approved by the City. All certificates and endorsements must be received and approved by the City before delivery commences. The City reserves the right to require complete, certified copies of all required insurance policies, at any time. E. Subcontractors. All subcontractors shall meet the requirements of this Section before commencing work. In addition, Contractor shall include all subcontractors as insureds under its policies or shall furnish separate certificates and endorsements for each subcontractor. All coverages for subcontractors shall be subject to all of the requirements stated herein. F. Freight. Contractor shall ensure that third party shippers contracted by Contractor have adequate insurance coverage for the shipped Equipment. Page 8 of 12 61147.02100\24471712.1 Section 15. LIENS. A. Contractor, subcontractors and suppliers will not make, file or maintain a mechanic’s or other lien or claim of any kind or character against the Equipment, for or on account of any labor, materials, fixtures, tools, machinery, equipment, or any other things furnished, or any other work done or performance given under, arising out of, or in any manner connected with the Agreement (such liens or claims referred to as “Claims”); and Contractor, subcontractor and suppliers expressly waive and relinquish any and all rights which they now have, or may subsequently acquire, to file or maintain any Claim and Contractor, subcontractor and suppliers agree that this provision waiving the right of Claims will be an independent covenant. B. Contractor will save and hold City harmless from and against any and all Claims that may be filed by a subcontractor, supplier or any other person or entity and Contractor will, at its own expense, defend any and all actions based upon such Claims and will pay all charges of attorneys and all costs and other expenses arising from such Claims. Section 16. TERMINATION OF AGREEMENT BY CITY. A. Should Contractor at any time refuse or fail to deliver the Equipment with promptness and diligence, or to perform any of its other obligations under the Agreement, City may terminate Contractor’s right to proceed with the delivery of the Equipment by written notice to Contractor. In such event City may obtain the Equipment by whatever method it may deem expedient, including the hiring of another contractor or other contractors and, for that purpose, may take possession of all materials, machinery, equipment, tools and appliances and exercise all rights, options and privileges of Contractor. In such case Contractor will not be entitled to receive any further payments until the Equipment is delivered. If City’s cost of obtaining the Equipment, including compensation for additional managerial and administrative services, will exceed the unpaid balance of the Agreement, Contractor will be liable for and will pay the difference to City. B. City may, for its own convenience, terminate Contractor’s right to pro ceed with the delivery of any portion or all of the Equipment by written notice to Contractor. Such termination will be effective in the manner specified in such notice, will be without prejudice to any claims which City may have against Contractor, and will not affect the obligations and duties of Contractor under the Agreement with respect to portions of the Equipment not terminated. C. On receipt of notice under Section 16.B, Contractor will, with respect to the portion of the Equipment terminated, unless the notice states otherwise, 1. Immediately discontinue such portion of the Equipment and the placing of orders for materials, facilities, and supplies in connection with the Equipment, 2. Unless otherwise directed by City, make every reasonable effort to procure cancellation of all existing orders or contracts upon terms satisfactory to City; and 3. Deliver only such portions of the Equipment which City deems necessary to preserve and protect those portions of the Equipment already in progress and to protect material, plant and equipment at the Equipment site or in transit to the Equipment site. D. Upon termination pursuant to Section 16.B, Contractor will be paid a pro rata portion of the compensation in the Agreement for any portion of the terminated Equipment already delivered, including material and services for which it has made firm contracts which are not canceled, it being understood that City will be entitled to such material and services. Upon determination of the amount of said pro rata compensation, City will promptly pay such amount to Contractor upon delivery by Contractor of the releases of liens and affidavit, pursuant to Section 7.C. Section 17. MISCELLANEOUS PROVISIONS. A. Delivery of Notices. All notices permitted or required under this Agreement shall be given to the respective parties at the following address or at such other address as the respective parties may provide in writing for this purpose: CITY: City of San Juan Capistrano 32400 Paseo Adelanto San Juan Capistrano, CA 92675 Attn: Eric Bauman, Utilities Department CONTRACTOR: OneSource, A Sonepar Company 4278 N. Harbor Boulevard Fullerton, CA 92835 Attn: Deborah Marshall Such notice shall be deemed made when personally delivered or when mailed, forty-eight (48) hours after deposit in the U.S. Mail, first class postage prepaid and addressed to the party at its applicable address. Actual notice shall be deemed adequ ate notice on the date actual notice occurred, regardless of the method of service. B. Assignment or Transfer. Contractor shall not assign or transfer any interest in this Agreement whether by assignment or novation, without the prior written consent of the City, which will not be unreasonably withheld. Provided, however, that claims for money due or to become due Contractor from the City under this Agreement may be assigned to a financial institution or to a trustee in bankruptcy, without such approval. Notice of any assignment or transfer, whether voluntary or involuntary, shall be furnished promptly to the City. C. Successors and Assigns. This Agreement shall be binding on the successors and assigns of the Parties. D. Amendment; Modification. No supplement, modification or amendment of this Agreement shall be binding unless executed in writing and signed by both Parties. E. Waiver. No waiver of any default shall constitute a waiver of any other default or breach, whether of the same or other covenant or condition. No waiver, benefit, privilege or Page 10 of 12 61147.02100\24471712.1 service voluntarily given or performed by a Party shall give the other Party any contractual rights by custom, estoppel or otherwise. F. Governing Law. This Agreement shall be governed by the laws of the State of California. Venue shall be in Orange County. G. Interpretation. Since the Parties or their agents have participated fully in the preparation of this Agreement, the language of this Agreement shall be construed simply, according to its fair meaning, and not strictly for or against any Party. H. No Third Party Beneficiaries. There are no intended third party beneficiaries of any right or obligation assumed by the Parties. I. Authority to Enter Agreement. Each Party warrants that the individuals who have signed this Agreement have the legal power, right and authority to make this Agreement and bind each respective Party. J. Invalidity; Severability. If any portion of this Agreement is declared invalid, illegal or otherwise unenforceable by a court of competent jurisdiction, the remaining provisions shall continue in full force and effect. K. Counterparts. This Agreement may be signed in counterparts, each of which shall constitute an original. L.City’s Right to Employ Other Contractors. City reserves its right to employ other contractors in connection with the Equipment. M. Entire Agreement. This Agreement constitutes the entire agreement between the Parties relative to the Equipment specified herein. There are no understandings, agreements, conditions, representations, warranties or promises with respect to this Agreement, except those contained in or referred to in the writing. [SIGNATURES ON FOLLOWING PAGE] Deborah Marshall Project Manager 2-1-2021 2/18/2021 EXHIBIT “A” EQUIPMENT SPECIFICATIONS, DELIVERY & FEE (INCLUDES SALES TAX) Rockwell Automation Centerline 2100 Motor Control Center MCC Cost Project Name: SMWD - Bear Brand Pump Station Project Item: MCC Created By: Jorge Trujillo Project ID #: 5250577/1 Date/Time: 12/07/20 - 13:24 MCC Description Net Price MCC Total Price $74,687.00 Includes tax NOTES: ™ ™ ™ ™ 12 Mo. Extended Warranty (for a total of 2-years from date of shipment) Leadtime is 14 weeks from approval to manufacture. Freight Included. Spare Parts not included. Startup, Training or any other services is not included unless listed above. ™ The above total reflects tax amounts for the ship address of 31546 Peppertree Bend, San Juan Capistrano, CA 92675 Rockwell Automation Centerline 2100 Motor Control Center Basic Structure Information Project Name: SMWD - Bear Brand Pump Station Project Item: MCC Created By: Jorge Trujillo Project ID #: 5250577/1 Date/Time: 12/07/20 - 13:24 Motor Control Center Details This MCC(s) was developed using an available fault current of 50,001 to 65,000 A. MCC configuration & pricing subject to change, if actual Available Fault Current differs. Motor Control Center Details Power System Type: Wye, 3-phase, 3-wire with solidly grounded neutral Voltage: 480 Volts / 60 Hertz Available Fault Current: 50,001 to 65,000 A Unit Nameplate Type: Phenolic - Black letters on white - Stainless Steel Screws Wiring Type: B-T Control and Power Terminal Blocks Wiring Diagram Location: Central location Arc Resistant MCC: Yes Device Limited: Motor Control Center short circuit protection provided by Rockwell Automation. IntelliCENTER Network: None Incoming Line Details MCC Connection Type: Main Circuit Breaker Incoming Line Cable Entry: Top Mounted Bus Details Main Bus Rating: 600A Main Bus Material: Copper / Tin Plated Main Bus Bracing: 65kA (rms symmetrical) Insulated Bus: None Selected Horizontal Ground Bus Size: 1/4" X 1" Horizontal Ground Bus Plating: Tin plated Copper Horizontal Ground Bus Location: Bottom Vertical Ground Bus Type: Unit Load Copper and Plug-in Copper Incoming Ground Lug Size: #6 AWG - 250 kcmil (2 Supplied as Standard) Incoming Ground Cable Size: None Selected Enclosure Details Enclosure Type: 1G - with Gasketed Doors. Bottom Plates Included NEMA 3R/4 Lifting Angle: No Section Depth: Front Mounted, 20" Deep Section Height: 90" High Stab Opening Protection: Automatic Shutters Isolation Barriers: Yes Wireway Tie Bar: Yes Space Heater Voltage: 120V Space Heater Thermostat: 1 Per Section External Mounting Channel: Yes Total Shipping Block(s): 3 Total Section(s): 4 Total Unit(s): 11 Section Modifications (Qty/Mods) Section Number Section Width (inches)Options/Modifications 1 20" N/A 2 20" N/A 3 20" N/A 4 35" N/A Rockwell Automation Centerline 2100 Motor Control Center Structure and Unit Specifications Project Name: SMWD - Bear Brand Pump Station Project Item: MCC Created By: Jorge Trujillo Project ID #: 5250577/1 Date/Time: 12/07/20 - 13:24 Unit Diagram Location: Central location ArcShield MCC: Device Limited STANDARD STRUCTURE / SECTION SPECIFICATIONS Line Voltage / Frequency: 480 Volts / 60 Hertz Class I Wiring Type: B-T Control and Power Terminal Blocks NEMA Enclosure Type: 1G - with Gasketed Doors. Bottom Plates Included QTY STANDARD STRUCTURE / SECTION SPECIFICATION DELIV PROG 1 POWER SYSTEM - WYE, 3-PHASE, 3-WIRE WITH SOLIDLY GROUNDED NEUTRAL SCII 2 GRD BUS SPLICE, (1) 0.25" × 1" (CU/TIN)SCII 1 SPACE HEATER, 200W, 120V, W/T-STAT PER SECT SCII 2 HORIZ PWR BUS SPLICE, 600A, CU/TIN SCII 2 SPACE HEATER, 200W, 120V, W/T-STAT PER SECT SCII 4 ARCSHIELD RESISTANT MCC SCII 3 AUTOMATIC SHUTTERS FOR STAB OPENINGS SCII 4 SECT DEPTH 20"SCII 4 NEMA ENCL TYPE 1 W/GASKET (DOORS ONLY)SCII 4 BASE SECTION SCII 4 BOTTOM CLOSING PLATE SCII 4 EXTERNAL MOUNTING CHANNEL SCII 4 HORIZ GRD BUS, 0.25" X 1" CU/TIN SCII 4 HORIZ PWR BUS, 600A, CU/TIN SCII 4 BUS BRACING 65KA RMS SYMMETRICAL SCII 3 ISOLATION BARRIER(S)SCII 3 VERT PWR BUS, 300A, CU/TIN SCII 3 VERT GRD BUS, UNIT LOAD CONNECT, CU/TIN SCII 3 VERT GRD BUS, PLUG-IN, CU/TIN SCII 3 WIREWAY TIE BAR(S)SCII STARTER / UNIT SPECIFICATIONS ID QTY CATALOG NUMBER SPACE FACTOR DELIV PROG 1 1 2155JB-F108LKB-13D-13GE-13HBA3-13HIC-13IC-13XB-49TJM-79LT-79UT-112A-750- 751HS-790A-900-911 3.5 ENG - 1 Power Wire Color, Non-Standard, Standard Colors: Black MTW in Size 1-2, Gray Hypalon in larger units (achieved by using TAPE at both ends, stabs not included) (per unit) - ENG - 5 Bulletin 800H, Pilot Light, Push-to-Test, Transformer Type, LED,800H-PRTH16?- FT2 - 11 Bulletin 700-HF Square Base Relay, 4PDT, 4-pole, 4 Form C, AgCdO Contacts,700-HF34?- FT2 - 1 Bulletin 800H, 3-Position Selector Switch (2 N.O. - 2 N.C.),800H-JR2B CMOD Note Text - Similar to standard option -3 - FT1 - 2 Rockwell Automation Bulletin 700-HR Dial Timing Relay, DPDT, 2 Form C, Multi-range, On- delay, Off-delay, One-shot, Repeat Cycle,700-HR52T? - FT2 - 1 Bulletin 800H, Push Button, Flush or Extended Head, Momentary Contact, Non-Illuminated (Standard Start or Stop Push Button),800H-*R*D* - FT2 - 1 Hobbs Elapsed Time Meter, 2.08"w x 1.02"h, 6 digit, 99999.9, non-reset (Option - 85T),20001U-17 - ENG - 1 500 watt extra capacity to Standard Control Transformer Fusing/Fuse Block Included - ENG - 3 Bulletin 800T/H, Contact block, addition to standard number of contacts,800T-XA - FT2 - 1 Convert SMC-Flex to SMC-50 with internal bypass, Nema 1/1G/12, (125HP-400HP)/(201A- 480A), 480V (6.0SF, 20" wide, 20" Deep, Bumped Back Bus) Includes Digital I/O Module (150-SM4), DIRECT REPLACEMENT FOR SMC-FLEX,150-SxxxNBD CMOD Note Text - Use SMC-Flex as base catalog string. No extra space required. DIRECT REPLACEMENT FOR SMC-FLEX - FT2 - 2 Space Heater Disconnect, single pole Bul. 1492 circuit breaker in the space heater circuit - FT2 - 3 Fingersafe Fuse Cover, for XFMR Control fuse with blown fuse indication - FT2 - 1 ArcShield Device Limited (1200A and below) - Arc Resistant Baffles (Nema 1 & 1G only) CMOD Note Text - See EPB Notes for proper application. The Arc Resistant baffles cannot be used with NEMA 12 fans. Device Limited ArcShield is limited to vented and non-vented NEMA 1 enclosures and non-vented NEMA 12 enclosures. - FT1 2 1 2193FZ-AKB-32TGM-79LT-79UT-98-99-112A-790A 0.5 FT1 - 1 CEWs FT mod (INTERNAL USE ONLY) CMOD Note Text - CEWs FT mod (INTERNAL USE ONLY) - FT1 3 1 2100-EKC2X4B-112A 6 ENG - 1 Customer Load Cables Exit(Bottom)-- - 1 Customer Supplied Equipment - Transfer Switch Receiving ,Handling, & Installation, 1000- 1200 Amps CMOD Note Text - For use with Customer Supplied Transfer Switches - see 2828 for other Customer Supplied Large Devices - ENG - 1 CEWs FT mod (INTERNAL USE ONLY) CMOD Note Text - CEWs FT mod (INTERNAL USE ONLY) - FT1 - 1 GE Zenith ZTS 225A, 3 pole, 277/480V, 3 phase, 4 wire open transition transfer switch. CMOD Note Text - Base catalog number 2100-E_C2X2B See EPB notes for proper application - ENG - 1 GE Zenith- Neutral Options 260A & 400A, Code [C]- ENG 4 1 2193FZ-AKB-37TGM-79LT-79UT-98-99-112A-790A 0.5 FT1 - 1 CEWs FT mod (INTERNAL USE ONLY) CMOD Note Text - CEWs FT mod (INTERNAL USE ONLY) - FT1 5 1 2193MT-CKC-45TJM-112A-790A 2 FT2 - 1 0.5 Space Factor Adder - FT2 6 2 2163UB-034NKB-3F-5LGR-5TLA-14DA2R1-14DFLPJ-14GER-14HBA6-14RLX-44TGM- 79LT-79UT-112A-751HS-790A 4 ENG - 1 Power Wire Color, Non-Standard, Standard Colors: Black MTW in Size 1-2, Gray Hypalon in larger units (achieved by using TAPE at both ends, stabs not included) (per unit) - ENG - 5 Bulletin 800H, Pilot Light, Push-to-Test, Transformer Type, LED,800H-PRTH16?- FT2 - 11 Bulletin 700-HF Square Base Relay, 4PDT, 4-pole, 4 Form C, AgCdO Contacts,700-HF34?- FT2 - 1 Bulletin 800H, 3-Position Selector Switch (2 N.O. - 2 N.C.),800H-JR2B CMOD Note Text - Similar to standard option -3 - FT1 - 2 Rockwell Automation Bulletin 700-HR Dial Timing Relay, DPDT, 2 Form C, Multi-range, On- delay, Off-delay, One-shot, Repeat Cycle,700-HR52T? - FT2 - 1 Bulletin 800H, Push Button, Flush or Extended Head, Momentary Contact, Non-Illuminated (Standard Start or Stop Push Button),800H-*R*D* - FT2 - 1 Hobbs Elapsed Time Meter, 2.08"w x 1.02"h, 6 digit, 99999.9, non-reset (Option - 85T),20001U-17 - ENG - 1 500 watt extra capacity to Standard Control Transformer Fusing/Fuse Block Included - ENG - 3 Bulletin 800T/H, Contact block, addition to standard number of contacts,800T-XA - FT2 - 1 Convert SMC-Flex to SMC-50 with internal bypass, Nema 1/1G/12, (125HP-400HP)/(201A- 480A), 480V (6.0SF, 20" wide, 20" Deep, Bumped Back Bus) Includes Digital I/O Module (150-SM4), DIRECT REPLACEMENT FOR SMC-FLEX,150-SxxxNBD CMOD Note Text - Use SMC-Flex as base catalog string. No extra space required. DIRECT REPLACEMENT FOR SMC-FLEX - FT2 - 2 Space Heater Disconnect, single pole Bul. 1492 circuit breaker in the space heater circuit - FT2 - 3 Fingersafe Fuse Cover, for XFMR Control fuse with blown fuse indication - FT2 - 1 1.0 Space Factor Adder - FT2 7 3 2100-BK10-112A 1 PE 8 1 2100-BK05-112A 0.5 PE DOCUMENTATION - CENTRAL LOCATION 11 Phenolic - Black letters on white - Stainless Steel Screws SC Total Space Factors Used = 24 Delivery Program Type = ENG Rockwell Automation Centerline 2100 Motor Control Center Unit List Project Name: SMWD - Bear Brand Pump Station Project Item: MCC Created By: Jorge Trujillo Project ID #: 5250577/1 Date/Time: 12/07/20 - 13:24 ID QTY Catalog Number / Unit Description 1 1 2155JB-F108LKB-13D-13GE-13HBA3-13HIC-13IC-13XB-49TJM-79LT-79UT-112A-750- 751HS-790A-900-911 / SMC Flex Soft Starter w/CB - 108A Rating - 75 HP with Circuit Breaker Thermal Magnetic (250A Trip) 2 1 2193FZ-AKB-32TGM-79LT-79UT-98-99-112A-790A / Feeder Circuit Breaker - 125A Frame Rating with 30A Trip 3 1 2100-EKC2X4B-112A / Full Sect Blank Mtg Plate w/ or w/o Disc with Fuse Clip Class - 1 Customer Load Cables Exit(Bottom) 4 1 2193FZ-AKB-37TGM-79LT-79UT-98-99-112A-790A / Feeder Circuit Breaker - 125A Frame Rating with 70A Trip 5 1 2193MT-CKC-45TJM-112A-790A / Main Circuit Breaker - 250A Frame Rating - Top Mounted with 225A Trip 6 2 2163UB-034NKB-3F-5LGR-5TLA-14DA2R1-14DFLPJ-14GER-14HBA6-14RLX-44TGM- 79LT-79UT-112A-751HS-790A / PowerFlex 753 AC Drive w/CB - 25 HP with Circuit Breaker Thermal Magnetic (60A Trip) 7 3 2100-BK10-112A / Blank Unit Door - 1.0 Space Factor 8 1 2100-BK05-112A / Blank Unit Door - 0.5 Space Factor Rockwell Automation Centerline 2100 Motor Control Center Unit Description Project Name: SMWD - Bear Brand Pump Station Project Item: MCC Created By: Jorge Trujillo Project ID #: 5250577/1 Date/Time: 12/07/20 - 13:24 General Information Line Voltage / Frequency: 480 Volts / 60 Hertz Power System Configuration: Wye, 3-phase, 3-wire with solidly grounded neutral Class I Wiring Type: B-T Control and Power Terminal Blocks NEMA Enclosure Type: 1G - with Gasketed Doors. Bottom Plates Included Available Fault Current: 50,001 to 65,000 A Unit Nameplate Type: Phenolic - Black letters on white - Stainless Steel Screws Delivery Program: ENG Unit Information Description Unit Features Unit Loc: 01A Del Prog: ENG Unit ID: 1 SMC - SMC Flex Soft Starter w/CB Rating 75 HP Name Plate Information PUMP #1 Catalog Number: 2155JB-F108LKB-13D-13GE-13HBA3-13HIC-13IC-13XB-49TJM- 79LT-79UT-112A-750-751HS-790A-900-911 Total Space Factor = 3.5 Wiring: NEMA Type B wiring Current Rating: 108A Circuit Breaker: Thermal Magnetic, 65kA at 480V (J6F Frame) (250A Trip) Control: Transformer with Secondary Fuse, Standard Capacity, Primary Fusing, 120V/60Hz Control Wiring: #14 AWG MTW (TEW) Cu (Tinned) Human Interface Module: LCD display numeric keypad - Door Mounted Features Included SMC Line Side (-13D) EtherNet/IP (for SMC) (-13GE) SMC HIM LCD display numeric keypad (-13HBA3) SMC HIC Fusing Provided (-13HIC) SMC Isolation Contactor provided (-13IC) SMC Pump Control (-13XB) Unit Ground Load Connector Tin Plated Cu (-79LT) Unit Grd Stab Tin Plated Cu (-79UT) Arc Resistant Unit Design (-112A) #14 AWG MTW (TEW) Cu (Tinned) (-750) Heat Shrink Type Markers (-751HS) 1 Aux and 1 Alarm-Internal-CB (-790A) 2 NO on Starter (-900) 2 NC on Starter (-911) Engineered Spec(s)/Modification(s) (1) Engineered Modification and/or Custom Diagram (1) Power Wire Color, Non-Standard, Standard Colors: Black MTW in Size 1-2, Gray Hypalon in larger units (achieved by using TAPE at both ends, stabs not included) (per unit) (5) Bulletin 800H, Pilot Light, Push-to-Test, Transformer Type, LED,800H-PRTH16? (11) Bulletin 700-HF Square Base Relay, 4PDT, 4-pole, 4 Form C, AgCdO Contacts,700- HF34? (1) Bulletin 800H, 3-Position Selector Switch (2 N.O. - 2 N.C.),800H-JR2B (2) Rockwell Automation Bulletin 700-HR Dial Timing Relay, DPDT, 2 Form C, Multi- range, On-delay, Off-delay, One-shot, Repeat Cycle,700-HR52T? (1) Bulletin 800H, Push Button, Flush or Extended Head, Momentary Contact, Non- Illuminated (Standard Start or Stop Push Button),800H-*R*D* (1) Hobbs Elapsed Time Meter, 2.08"w x 1.02"h, 6 digit, 99999.9, non-reset (Option - 85T),20001U-17 (1) 500 watt extra capacity to Standard Control Transformer Fusing/Fuse Block Included (3) Bulletin 800T/H, Contact block, addition to standard number of contacts,800T-XA (1) Convert SMC-Flex to SMC-50 with internal bypass, Nema 1/1G/12, (125HP- 400HP)/(201A-480A), 480V (6.0SF, 20" wide, 20" Deep, Bumped Back Bus) Includes Digital I/O Module (150-SM4), DIRECT REPLACEMENT FOR SMC-FLEX,150-SxxxNBD (2) Space Heater Disconnect, single pole Bul. 1492 circuit breaker in the space heater circuit (3) Fingersafe Fuse Cover, for XFMR Control fuse with blown fuse indication (1) ArcShield Device Limited (1200A and below) - Arc Resistant Baffles (Nema 1 & 1G only) Unit Loc: 01H Del Prog: PEII Unit ID: 8 DOOR - Blank Unit Door Catalog Number: 2100-BK05-112A Total Space Factor = 0.5 Features Included Arc Resistant Unit Design (-112A) Unit Loc: 01J Del Prog: PEII Unit ID: 7 DOOR - Blank Unit Door Catalog Number: 2100-BK10-112A Total Space Factor = 1 Features Included Arc Resistant Unit Design (-112A) Unit Loc: 01L Del Prog: PEII Unit ID: 7 DOOR - Blank Unit Door Catalog Number: 2100-BK10-112A Total Space Factor = 1 Features Included Arc Resistant Unit Design (-112A) Unit Loc: 02A Del Prog: PEII Unit ID: 7 DOOR - Blank Unit Door Catalog Number: 2100-BK10-112A Total Space Factor = 1 Features Included Arc Resistant Unit Design (-112A) Unit Loc: 02C Del Prog: FT1 Unit ID: 2 FCB - Feeder Circuit Breaker Rating 30A Name Plate Information AIR COMPRESSOR Overload Relay(s) Motor Full Load Current (FLC) = Not Available Catalog Number: 2193FZ-AKB-32TGM-79LT-79UT-98-99-112A-790A Total Space Factor = 0.5 Circuit Breaker: Thermal Magnetic, 65kA at 480V (30) with Frame Rating of 125A (G6C Frame) , Plug-In Unit, 30A Trip Lugs Supplied: Std Mech/Lug Pads, 1/0 AWG Size Wire, 1 Cables per Phase Features Included Unit Ground Load Connector Tin Plated Cu (-79LT) Unit Grd Stab Tin Plated Cu (-79UT) 1 NO Aux on Disc. Switch (-98) 1 NC Aux on Disc. Switch (-99) Arc Resistant Unit Design (-112A) 1 Aux and 1 Alarm-Internal-CB (-790A) Engineered Spec(s)/Modification(s) (1) CEWs FT mod (INTERNAL USE ONLY) (1) Engineered Modification and/or Custom Diagram Unit Loc: 02D Del Prog: FT1 Unit ID: 4 FCB - Feeder Circuit Breaker Rating 70A Name Plate Information 45KVA TRANSFORMER Overload Relay(s) Motor Full Load Current (FLC) = Not Available Catalog Number: 2193FZ-AKB-37TGM-79LT-79UT-98-99-112A-790A Total Space Factor = 0.5 Circuit Breaker: Thermal Magnetic, 65kA at 480V (70) with Frame Rating of 125A (G6C Frame) , Plug-In Unit, 70A Trip Lugs Supplied: Std Mech/Lug Pads, 1/0 AWG Size Wire, 1 Cables per Phase Features Included Unit Ground Load Connector Tin Plated Cu (-79LT) Unit Grd Stab Tin Plated Cu (-79UT) 1 NO Aux on Disc. Switch (-98) 1 NC Aux on Disc. Switch (-99) Arc Resistant Unit Design (-112A) 1 Aux and 1 Alarm-Internal-CB (-790A) Engineered Spec(s)/Modification(s) (1) CEWs FT mod (INTERNAL USE ONLY) (1) Engineered Modification and/or Custom Diagram Unit Loc: 02E Del Prog: ENG Unit ID: 6 VFD - PowerFlex 753 AC Drive w/CB Rating 25 HP (Normal Duty) Wiring Diagram 10005682754 Catalog Number: 2163UB-034NKB-3F-5LGR-5TLA-14DA2R1-14DFLPJ-14GER- 14HBA6-14RLX-44TGM-79LT-79UT-112A-751HS-790A Total Space Factor = 4 Wiring: NEMA Type B wiring Output Current Rating: 34A Circuit Breaker: Thermal Magnetic, 100kA at 480V (G6C Frame) (60A Trip) Human Interface Module: LCD full numeric keypad - Door Mounted Control: Transformer with Secondary Fuse, Standard Capacity, Primary Fusing, 120V/60Hz Control Wiring: #16 AWG MTW(TEW) Cu Features Included Selector Switch: HAND-OFF-AUTO (-3F) Pilot Light(s): RUN-AT SPEED Type: LED Push To Test, Color(s): Green, Red (-5LGR) Pilot Light(s): FAULT Type: LED Push To Test, Color(s): Amber (-5TLA) Drive 120VAC w/ I/O (-14DA2R1) Drive input fuses - Bussman (-14DFLPJ) Dualport Ethernet (for VFD) (-14GER) Drive Line Reactor (-14RLX) Unit Ground Load Connector Tin Plated Cu (-79LT) Unit Grd Stab Tin Plated Cu (-79UT) Arc Resistant Unit Design (-112A) Heat Shrink Type Markers (-751HS) 1 Aux and 1 Alarm-Internal-CB (-790A) Engineered Spec(s)/Modification(s) (1) Engineered Modification and/or Custom Diagram (1) Power Wire Color, Non-Standard, Standard Colors: Black MTW in Size 1-2, Gray Hypalon in larger units (achieved by using TAPE at both ends, stabs not included) (per unit) (5) Bulletin 800H, Pilot Light, Push-to-Test, Transformer Type, LED,800H-PRTH16? (11) Bulletin 700-HF Square Base Relay, 4PDT, 4-pole, 4 Form C, AgCdO Contacts,700- HF34? (1) Bulletin 800H, 3-Position Selector Switch (2 N.O. - 2 N.C.),800H-JR2B (2) Rockwell Automation Bulletin 700-HR Dial Timing Relay, DPDT, 2 Form C, Multi- range, On-delay, Off-delay, One-shot, Repeat Cycle,700-HR52T? (1) Bulletin 800H, Push Button, Flush or Extended Head, Momentary Contact, Non- Illuminated (Standard Start or Stop Push Button),800H-*R*D* (1) Hobbs Elapsed Time Meter, 2.08"w x 1.02"h, 6 digit, 99999.9, non-reset (Option - 85T),20001U-17 (1) 500 watt extra capacity to Standard Control Transformer Fusing/Fuse Block Included (3) Bulletin 800T/H, Contact block, addition to standard number of contacts,800T-XA (1) Convert SMC-Flex to SMC-50 with internal bypass, Nema 1/1G/12, (125HP- 400HP)/(201A-480A), 480V (6.0SF, 20" wide, 20" Deep, Bumped Back Bus) Includes Digital I/O Module (150-SM4), DIRECT REPLACEMENT FOR SMC-FLEX,150-SxxxNBD (2) Space Heater Disconnect, single pole Bul. 1492 circuit breaker in the space heater circuit (3) Fingersafe Fuse Cover, for XFMR Control fuse with blown fuse indication (1) 1.0 Space Factor Adder Unit Loc: 03A Del Prog: FT2 Unit ID: 5 MCB - Main Circuit Breaker Rating 225A Catalog Number: 2193MT-CKC-45TJM-112A-790A Total Space Factor = 2 Circuit Breaker: Thermal Magnetic, 65kA at 480V (225) with Frame Rating of 250A (- NONE- Frame) , Top Mounted, 225A Trip Lugs Supplied: Std Mech/Lug Pads, 250 kcmil Size Wire, 1 Cables per Phase Features Included Arc Resistant Unit Design (-112A) 1 Aux and 1 Alarm-Internal-CB (-790A) Engineered Spec(s)/Modification(s) (1) 0.5 Space Factor Adder (1) Engineered Modification and/or Custom Diagram Unit Loc: 03E Del Prog: ENG Unit ID: 6 VFD - PowerFlex 753 AC Drive w/CB Rating 25 HP (Normal Duty) Wiring Diagram 10005682754 Catalog Number: 2163UB-034NKB-3F-5LGR-5TLA-14DA2R1-14DFLPJ-14GER- 14HBA6-14RLX-44TGM-79LT-79UT-112A-751HS-790A Total Space Factor = 4 Wiring: NEMA Type B wiring Output Current Rating: 34A Circuit Breaker: Thermal Magnetic, 100kA at 480V (G6C Frame) (60A Trip) Human Interface Module: LCD full numeric keypad - Door Mounted Control: Transformer with Secondary Fuse, Standard Capacity, Primary Fusing, 120V/60Hz Control Wiring: #16 AWG MTW(TEW) Cu Features Included Selector Switch: HAND-OFF-AUTO (-3F) Pilot Light(s): RUN-AT SPEED Type: LED Push To Test, Color(s): Green, Red (-5LGR) Pilot Light(s): FAULT Type: LED Push To Test, Color(s): Amber (-5TLA) Drive 120VAC w/ I/O (-14DA2R1) Drive input fuses - Bussman (-14DFLPJ) Dualport Ethernet (for VFD) (-14GER) Drive Line Reactor (-14RLX) Unit Ground Load Connector Tin Plated Cu (-79LT) Unit Grd Stab Tin Plated Cu (-79UT) Arc Resistant Unit Design (-112A) Heat Shrink Type Markers (-751HS) 1 Aux and 1 Alarm-Internal-CB (-790A) Engineered Spec(s)/Modification(s) (1) Engineered Modification and/or Custom Diagram (1) Power Wire Color, Non-Standard, Standard Colors: Black MTW in Size 1-2, Gray Hypalon in larger units (achieved by using TAPE at both ends, stabs not included) (per unit) (5) Bulletin 800H, Pilot Light, Push-to-Test, Transformer Type, LED,800H-PRTH16? (11) Bulletin 700-HF Square Base Relay, 4PDT, 4-pole, 4 Form C, AgCdO Contacts,700- HF34? (1) Bulletin 800H, 3-Position Selector Switch (2 N.O. - 2 N.C.),800H-JR2B (2) Rockwell Automation Bulletin 700-HR Dial Timing Relay, DPDT, 2 Form C, Multi- range, On-delay, Off-delay, One-shot, Repeat Cycle,700-HR52T? (1) Bulletin 800H, Push Button, Flush or Extended Head, Momentary Contact, Non- Illuminated (Standard Start or Stop Push Button),800H-*R*D* (1) Hobbs Elapsed Time Meter, 2.08"w x 1.02"h, 6 digit, 99999.9, non-reset (Option - 85T),20001U-17 (1) 500 watt extra capacity to Standard Control Transformer Fusing/Fuse Block Included (3) Bulletin 800T/H, Contact block, addition to standard number of contacts,800T-XA (1) Convert SMC-Flex to SMC-50 with internal bypass, Nema 1/1G/12, (125HP- 400HP)/(201A-480A), 480V (6.0SF, 20" wide, 20" Deep, Bumped Back Bus) Includes Digital I/O Module (150-SM4), DIRECT REPLACEMENT FOR SMC-FLEX,150-SxxxNBD (2) Space Heater Disconnect, single pole Bul. 1492 circuit breaker in the space heater circuit (3) Fingersafe Fuse Cover, for XFMR Control fuse with blown fuse indication (1) 1.0 Space Factor Adder Unit Loc: 04A Del Prog: ENG Unit ID: 3 PLAT - Full Sect Blank Mtg Plate w/ or w/o Disc Rating 0A Wiring Diagram 10003179671 Name Plate Information ATS Catalog Number: 2100-EKC2X4B-112A Total Space Factor = 6 Disconnect Type = No Disconnect Means Required Section Width 35" Wide Working Depth 14" Deep Features Included Arc Resistant Unit Design (-112A) Engineered Spec(s)/Modification(s) (1) Customer Load Cables Exit(Bottom) (1) Customer Supplied Equipment - Transfer Switch Receiving ,Handling, & Installation, 1000-1200 Amps (1) Engineered Modification and/or Custom Diagram (1) CEWs FT mod (INTERNAL USE ONLY) (1)GE Zenith ZTS 225A, 3 pole, 277/480V, 3 phase, 4 wire open transition transfer switch (1) GE Zenith - Neutral Options 260A & 400A, Code [C] Rockwell Automation Centerline 2100 Motor Control Center Unit Nameplate Report Project Name: SMWD - Bear Brand Pump Station Project Item: MCC Created By: Jorge Trujillo Project ID #: 5250577/1 Date/Time: 12/07/20 - 13:24 Master Nameplate Type - No Master Nameplate Supplied Unit Nameplate Type - Phenolic - Black letters on white - Stainless Steel Screws (4 lines) (Maximum characters per line is 25 / 22 / 22 / 25) Section 1 Location: 01A SMC (75 HP) Space Factor: 3.5 Wiring Diagram Number: N/A Location: 01H DOOR Space Factor: 0.5 Wiring Diagram Number: 10002119343 Location: 01J DOOR Space Factor: 1 Wiring Diagram Number: 10002117454 Location: 01L DOOR Space Factor: 1 Wiring Diagram Number: 10002117454 Section 2 Location: 02A DOOR Space Factor: 1 Wiring Diagram Number: 10002117454 Location: 02C FCB Space Factor: 0.5 Wiring Diagram Number: N/A AIR COMPRESSOR Location: 02D FCB Space Factor: 0.5 Wiring Diagram Number: N/A 45KVA TRANSFORMER Location: 02E VFD (25 HP) Space Factor: 4 Wiring Diagram Number: 10005682754 Section 3 Location: 03A MCB Space Factor: 2 Wiring Diagram Number: N/A Location: 03E VFD (25 HP) Space Factor: 4 Wiring Diagram Number: 10005682754 Section 4 Location: 04A PLAT Space Factor: 6 Wiring Diagram Number: 10003179671 Rockwell AutomationCenterline 2100 Motor Control CenterFront Elevation Project Name: SMWD - Bear Brand Pump Station Project Item: MCC Created By: Jorge Trujillo Project ID #: 5250577/1 Date/Time: 12/07/20 - 13:24NOTE: Dimensions are subject to change after design review.ENCLOSURE: NEMA Type 1G (General Purpose with Gasketed Doors and Bottom Closing Plates) Estimated Heat Loss: 1807 watts BTU/hr Required: 6166 Air Conditioning Tons: 0.52 Estimated Weight: 2000 lb (907 kg) Heat loss values are for estimating purposes only. Rockwell Automation Centerline 2100 Motor Control Center Specifications Project Name: SMWD - Bear Brand Pump Station Project Item: MCC Created By: Jorge Trujillo Project ID #: 5250577/1 Date/Time: 12/07/20 - 13:24 1.0 General The Motor Control Center (MCC) shall be constructed to meet or exceed the requirements within NEMA ICS3-322, UL845, CSA, and IEC 439-1 for MCC. The MCC shall be designed, manufactured, and tested in facilities registered to ISO9001 quality standards. The MCC enclosure shall be NEMA Type 1G - with Gasketed Doors. Bottom Plates Included. Any gasketing shall be closed cell neoprene material. Open cell gasketing shall not be acceptable. The MCC shall be rated for a 480 Volts / 60 Hertz system with an available fault current of 50,001 to 65,000 A. Each short circuit protective device shall be rated to interrupt this fault current. Provisions for terminating a neutral wire at the MCC need not be provided. This MCC(s) was developed using an available fault current of 50,001 to 65,000 A. MCC configuration & pricing subject to change, if actual Available Fault Current differs. The MCC shall be designed for use with a power system configured as a Wye, 3-phase, 3-wire with solidly grounded neutral. This MCC provides Type 2 accessibility per IEEE C37.20.7 when available short circuit current " 65kA and protected by one of the following devices: UL Listed Fuses Class L – Any Fuse " 1200 A Class R – Any Fuse " 600 A Class J – Any Fuse " 600 A UL Listed Molded Case Circuit Breakers Allen-Bradley – Bulletin 140G, Frame G, H, J, K, M, or N Allen-Bradley – Bulletin 140U, Frame I, JD, or K Device Limited ArcShield: Motor Control Center short circuit protection provided by Rockwell Automation. 2.0 Vertical Sections The vertical sections shall be 90" (2286 mm) high and 20" (508mm) deep. To assure structural rigidity, vertical sections shall have internal base mounting angles at the bottom, redundant external mounting channels at the bottom and external lifting angles at the top running continuous within each shipping block. Lifting eyelets at the top are not acceptable. To minimize the chance of fault propagation to adjacent sections, each vertical section shall have side sheets extending the full height and depth of the section. 3.0 Incoming Line Compartments The Main Circuit Breaker shall be Top entry. The size and quantity of incoming cables shall be shown on the drawings. 4.0 Wireways Horizontal wireways of standard sections, both top and bottom, shall be not less than 6’’ (150mm) high. To prevent damage to cable insulation, the wireway opening between sections shall have rounded corners and the edges shall be rolled back. The vertical wireway shall be approximately 4.4" (111mm) wide. A permanent vertical wireway wall shall separate the units from the vertical wireway, and remain intact even when the units are removed. If a permanent wireway wall cannot be provided, tie bars shall be included in each vertical wireway. 5.0 Power Bus Bars The power bus system shall be supported, braced, and isolated by a bus support molded of a high strength, non-tracking glass-filled polyester material. Bus bracing shall be rated to withstand the fault current listed in Section 1.0 of this specification, but shall not be rated less than 65kA (rms symmetrical). The horizontal bus shall be continuously braced within each section. It shall be Copper / Tin Plated and rated 600A. To ensure the reliability of the splice connections, both ends of the horizontal bus splices shall have at least two (2) bolts. The vertical bus shall be continuously braced and sandwiched in a glass-filled polyester molding. The bus shall be isolated from the user via a red non-metallic molded cover. The vertical bus shall be copper with the same plating as the horizontal bus, and shall accommodate plug-in loads totaling up to600A. The horizontal bus shall be connected to the vertical bus with two (2) bolts, and each bolt shall be independently capable of handling the load. 6.0 Ground Bus Bars The horizontal ground bus bar shall be tin-plated copper and located in the Bottom horizontal wireway. The size of the horizontal ground bus shall be 1/4" x 1" (6.4 x 25.4mm). A grounding stab shall be provided on each plug-in unit, such that the stab engages onto a copper vertical ground bus prior to the power stabs engaging. A grounding point shall be provided at each starter unit for purposes of landing the ground wire coming from the motor. This grounding point shall be directly tied to the horizontal ground bus. 7.0 Isolation and Insulation Automatic Shutters shall be provided, so that personnel are not exposed to live vertical bus bars and so that the bus is isolated from arcing faults. 8.0 Units 8.1 Unit Mounting After insertion, each plug-in unit shall be held in place by a latch that is located at the front of the unit. Multi-turn latches requiring more than ten (10) turns per latch shall not be acceptable. Plug-in stabs shall be mounted in a polyester molding at the rear of the unit. Wiring from the unit disconnecting means to the plug-in stabs shall be routed into this molding such that the wiring is not exposed at the rear of the unit. Non-reversing starters shall be plug-in design through 250A. The unit door shall be fastened to the stationary structure (not the unit itself), so that the door can be closed when the unit has been removed. The door shall be hinged on the left-hand side so that it opens away from the vertical wireway. 8.2 Disconnecting Means The operator handle of all units shall be interlocked with the MCC frame, so that a unit insert cannot be withdrawn or inserted when the operator is in the ON position. 8.3 Starters No motor starters shall be included in the MCC. 8.4 Terminal Blocks To minimize exposure to live terminals, terminal blocks shall be mounted within each unit, not in the vertical wireway. On non-plug-in (frame mounted) units, terminal blocks need not be pull-apart style. On plug-in units, control terminal blocks shall be pull-apart style. 8.5 Control Station Pilot devices shall be of NEMA or IEC design. 8.6 Documentation Wiring diagrams shall be provided at a centralized location in the MCC. The diagrams shall show the exact devices inside the unit and shall not be a generic diagram. The manufacturers unit wiring diagrams, elevation drawings, and floor plan shall be available for review prior to placement of the order. 9.0 Finish Standard paint for any exterior surfaces is ANSI 49 medium light gray, and standard paint for all vertical wireways and unit back plates is gloss white. All unpainted parts shall be plated for corrosion resistance. Rockwell Automation Centerline 2100 Motor Control Center Cancellation Policy Project Name: SMWD - Bear Brand Pump Station Project Item: Created By: Jorge Trujillo Project ID #: 5250577/1 Date/Time: 12/07/20 - 13:24