Loading...
17-1017_PALP INC., DBA EXCEL PAVING COMPANY_Addendum #4 32400 PASEO ADELANTO MEMBERS OF THE CITY COUNCIL SAN JUAN CAPISTRANO,CA 92675 (949)493-1171 ?�� IInaelti SERGIO FARIAS (949)493-1053 Fax 119+IIIStlQ 1961 KERRY K.FERGUSON www.,canjuancnpi•clrano.a 1776 BRIAN L.MARYOTT * • PAM PATTERSON, ESQ. . r DEREK REEVE ADDENDUM # FOUR Subject: Del Obispo Street Widening Project— Calle Aspero to Paseo De La Paz CIP 16102 Please see the attached responses to the questions regarding the subject project. Please see the attached SDG&E latest utility relocation plans. All other terms and conditions remain the same. FOR THE CITY OF SAN JUAN CAPISTRANO George Af\arez, P.E. Date City Engineer San Juan Capistrano: Preserving the Past to Enhance the Future " printed on 100%recycled paper Del Obispo Street Widening Project — Calle Aspero to Paseo De La Paz CIP 16102 Questions 1. Permits, Inspections & License Fees: in reference to ARTICLE 27 — PERMIT AND INSPECTION FEE ALLOWANCE in the "Instructions to Bidders" and ARTICLE 18 — PERMITS AND LICENSES in the "General Conditions", both of these sections of the specs indicate "the Bid Form contains an allowance for the Contractor's cost of acquiring traffic control permits and for construction inspection fees that may be charged to the Contractor by the Agency of Jurisdiction." However, there does not appear to be any allowance ($) amount indicated on the bid form. Please provide the indicated allowance amount for Permits & Inspections, or clarify the City's intent in this regard. Response: City is the only agency of jurisdiction that has to approve the traffic control plans. 2. Time For Completion: The time for completion indicated in the Contract is 300 calendar days (almost 10 months), which seems significantly longer than it should take to complete the proposed improvements. Is 300 calendar days correct? If so, are there any scheduling constraints that we need to be aware of (e.g. phasing of the work, utility relocation(s) by others, etc.)? Response: Yes, 300 calendar days is correct. We do not anticipate any scheduling constrains at this time. The project involves utility coordination; however, utility works should be completed prior to start of construction. 3. Anticipated Start Date: when does the City anticipate this project starting? Response: Late October, 2017. 4. SDG&E Relocations: Per Construction Note 7 on the Street Improvement Plans, there are some power poles, guy wires, pull boxes, etc. that need to be relocated by SDG&E as part of the street widening improvements. Please advise on the status of the City's coordination with SDG&E. Will their work be completed prior to the start of construction, or do we need to coordinate with SDG&E to relocate their facilities during construction? If we need to coordinate, how much time does SDG&E need to complete their work? Are there any other utilities/facilities that need to be relocated by others? Response: Within one week of issuance of the Notice to Proceed, the Contractor shall use the services of a licensed surveyor to stake the back of sidewalk at the new SDG&E's new pole P259938 and the new stub pole. Copies of the facilities relocation plans prepared by SDG&E are attached. Upon completion of the staking, SDG&E will begin construction and will complete relocation of all overhead and underground facilities within two calendar weeks. it DEL OBISPO ST WIDENING UG RELOCATION WORK IN CONJUNCTION WITHVERHEAD O � WORK ORDER 2564991 PROJ# 650673=020 SCALE gSAFRo S ITE 0 2 I pqS �� H 120188 4 I Fo �e N EX , 3316 j INTERCEPT & EXTEND INST D ON EX . 1 — EB5 " PRI E2 W. 0 . 2716120 I� , (ADJUST TO NEW GRADE) i C . P . I _ INST' D807 1 �/ C X . 3582 3PH TERM 5 D 1 O W. O . 2564991 �'� �� ST' D ON VICINITY MAP (SEE POLE / W. 0 . 271 6120 No SCALE T.GUIDE #972-82 NOTES BELOW) EX . P 191318 , ( l LOCATION TO / ' i (FOR SECTIONALIZING) Il , l BE—RELOCATED c TO LOCATE as la - GB- _ - G so - -GB- --BC- as- 8C- - 89- - , — 41A— II 15 ' <i a �_ t s - r - I� 37 00 381 0 36+00 I I n > o - 39+00 � z — - - -- J N34'50 3 4� 00 OBISPO - - STR DE - �� X40 �'' _ET - - - com z 00 / o o = /W� O m 00 00 CaZ> CO 0 D m � U) STUB 8c PLUG c 3 — E135" PRI INTERCEPT & EXTEND - » - 0 p > O m STA. 36+34 APPROX . EX . 3- E135 PRI 3 SDG&E GRD rn z F o zFFj 0 Oma - N O D rn n J m �u ' I / U O * CABLE POLE NOTES � N SDG&E % a� o o 1 -5" RISER - o 0 (on 0 CITY CONTRACTOR WILL SURVEY & STAKE NEW BACK OF SIDEWALK. COMM GRD UP COMM o M CITY WILL MEANDER THE SUB— DRAIN PIPE UNDER THE SIDEWALK AT THE NEW POLE LOCATION TO AVOID UNDERMINING ��+ � � DETAIL � � � � '` NOTES AND EXCESS WATER AT THE NEW POLE LOCATION . Call 2 Working Days Before You Dig! O ALL WORK TO BE DONE BY UTILITY 1-800-227-2600 M M o W Copyright 2003 San Diego Gas & Electric Company. All rights reserved. N c Removal of this copyright notice without permission is not permitted under law. UU n DEL BI O ST WIDENING UG RELOCATION IN WORKCONJUNCTIONWITH OVERHEAD O � WORK ORD R 2564991, PROJ# 650673=020 SCALE 0 NTS 911A" i 2 3O 1000 XEPECN - PEJ AE 287 ' E I SWI . 195 - 42 - L I CABLE POLE I E 1 201 88 EX . 3582 30 TERM 1 P258837 4 X . 331 6 , 3 - T D 1 52908 I INST ' D ON Q I INST ' D ON INST' D ON 5 W . 0 . 2716120 ® 0 W . 0 . 2564991 W . 0 . 271 6120 0z j*l 0 W v DEL OBISPO STREET m > 0o r (-) > 0 C) = x o � C coo coz0 i N N D C Oni- �7 OD 0 m 0 zz0 0 ;D Cu IJ u 11 0 o - C) n � n M ;;u 0 0 00 Cq M o M C 0 00 O C i n 0 C) 0 O 4 T U w � � 0 0 0 N F F, o o Copyright 2003 San Diego Gas & Electric Company. All rights reserved. N Removal of this copyright notice without permission is not permitted under law. n i DEL OBISP ST WIDENING, OH RE WORK IN CONJUNCTION WITH UNDERGROUND WORK ORDER 2564990, PROJ# 650673=030 gSpFRo S ITE SCALE Qo / 0 30 0 ti -<ND- / O OF pq2 NEW CABLE POLE P258837 3 INST: GANG SWI. 195-42-L / (ANCHOR NOT REQUIRED VICINITY MAP ' DUE TO SLACK SPAN) NO SCALE T.GUIDE #972-B2 / ' EX. STA.195-90 EX. 636AER ALF30N 2 1 -15 HE APPROX. 100FT. P21442 MAKE CONNECTIONS ® NEW C.P. PROTECT IN PLACE SLACK SPAN CITY TO PROVIDE 18 INCHES (REFERENCE ONLY) CLEARANCE FROM FACE OF NEW EX. SWI. CAP CURB TO FACE OF EXISTING POLE AT&T 195-75cw 1 � I POLE PROTECT INP21443 PLACE EX. CABLE POLE (REFERENCE ONLY) H.S. SWI.195-35 INST: DOWN ANCHOR GUY ! - P252231 _ — - - R/w PROTECT IN PLACE (REFERENCE ONLY) - - -'• EX 636 q ON (/� c F - / L m 1 - - -_ ._- ..� r i r '; ,..\\ r � ..-'• F i /6J6 \�i��f '� \\F �_ __ -- I L \ -.. _ ___-- — —8`J----B`�----8`�--_—_�GB—_--GB—_.__GB— '^ 3 VJ _ _F_Gg—=F c --- 3�==e®— — , —m —ce—m -- _ GB----G > �Ga GB —=—GB--.—_—GB- --- -_ --_ '� i � I D t ---- _ :GB- -GB— GB•. --- _ —f�BG— g"'=__--�[ —_.—'_ -_�_ - - __..__-- -- _ ri~ - _-_ (0 co co ISI __ nt Co 3700 i 34100 i _— 0 i ,'• —+-_-`f'�I3 ' 38t Z 3-- t t I li 32,+001co 300 ro i _ _. _ __-_.- _._-_ alb :. -._-__- __.__ __ __-_- __-_ ''> _--_ _. r ,,.•;, _ _ __- -_ I 31'400 (7 — - / DE D L OBISPO STREET - - - - - - — m F9 - _ 1 �- - - v o 0' o zz EX. 2-#8 OVERHEAD REMOVE EX. CABLE POLE N o TO EX. ST. LIGHT TO REMAIN P191318 & GANG SWITCH 4 D n (� (REFERENCE ONLY) 195-18. FACILITY TO BE REPLACED BY NEW CABLE POLE 0 j (SEE LOCATION 3) o o • REMOVE GUY TO STUB POLE 5 SDG&E GRD ' ' ' o «1 0 REMOVE STUB POLE P191321 , 6 O o DOWN GUYS AND ANCHORS o I m ' W N T II ' i p�4 SDG&E p CD o 1 -5° RISER o COMM GRD r n �i�/ ALL WORK TO BE DONE BY UTILITY COMM —, z NEW CP DETAIL P O Cn � .Z7 /ll n^VI\I F9 TJ o < O Copyright 2003 San Diego Gas & Electric Company. All rights reserved. c O Removal of this copyright notice without permission is not permitted under law.